Name |
Description |
Unit |
Reqd |
Perm |
Proposed |
Status |
|
A (BLDG) |
First Floor - Height |
Mt. |
2.75
|
-
|
3.05
|
OK
|
Mezzanine @ Ground Floor - Height |
Mt. |
2.75
|
-
|
3.05
|
OK
|
Ground Floor - Height |
Mt. |
2.75
|
-
|
3.05
|
OK
|
Plinth - Height |
Mt. |
0.45
|
-
|
0.86
|
OK
|
Basement Floor - Height |
Mt. |
2.40
|
-
|
3.90
|
OK
|
|
A (BLDG) |
Terrace Floor - Height |
Mt. |
1.00
|
1.20
|
0.92
|
Failed
|
|
A (BLDG) |
Basement Floor - Height Below GL |
Mt. |
|
-
|
2.44
|
OK
|
Basement Floor - Area |
Sq.Mt. |
|
-
|
-NA-
|
Failed
|
Basement Floor - Ventilation Area (Sq.mt.) |
Sq.Mt. |
-
|
|
5.13
|
OK
|
|
A (BLDG) |
Area |
Sq.Mt. |
|
-
|
-
|
OK
|
Status |
|
|
|
-
|
OK
|
Total |
Area |
Sq.Mt. |
|
-
|
-
|
OK
|
|
A (BLDG) |
No. of Floors |
No. |
|
-
|
3
|
OK
|
No. of Tenements |
No. |
|
-
|
4
|
OK
|
|
FIRST FLOOR PLAN |
STAIRCASE - Flight Width |
Mt. |
0.750
|
|
1.039
|
OK
|
STAIRCASE - Tread Width |
Mt. |
0.225
|
|
0.254
|
OK
|
STAIRCASE - Riser Height |
Mt. |
|
0.200
|
0.153
|
OK
|
STAIRCASE - Riser No. On Flight |
No. |
|
-
|
10
|
OK
|
STAIRCASE - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
GROUND FLOOR PLAN |
STAIRCASE - Flight Width |
Mt. |
0.750
|
|
1.039
|
OK
|
STAIRCASE - Tread Width |
Mt. |
0.225
|
|
0.254
|
OK
|
STAIRCASE - Riser Height |
Mt. |
|
0.200
|
0.153
|
OK
|
STAIRCASE - Riser No. On Flight |
No. |
|
-
|
10
|
OK
|
STAIRCASE - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
TERRACE FLOOR PLAN |
STAIRCABIN - Flight Width |
Mt. |
-
|
|
1.039
|
OK
|
STAIRCABIN - Tread Width |
Mt. |
-
|
|
0.254
|
OK
|
STAIRCABIN - Riser Height |
Mt. |
|
-
|
-
|
OK
|
STAIRCABIN - Riser No. On Flight |
No. |
|
-
|
-
|
OK
|
STAIRCABIN - Cabin Ht. |
Mt. |
2.100
|
-
|
2.440
|
OK
|
MEZZANINE @ GROUND FLOOR PLAN |
STAIRCASE - Flight Width |
Mt. |
0.750
|
|
1.039
|
OK
|
STAIRCASE - Tread Width |
Mt. |
0.225
|
|
0.254
|
OK
|
STAIRCASE - Riser Height |
Mt. |
|
0.200
|
0.153
|
OK
|
STAIRCASE - Riser No. On Flight |
No. |
|
-
|
10
|
OK
|
STAIRCASE - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
BASEMENT FLOOR PLAN |
Fire Escape Staircase - Flight Width |
Mt. |
0.900
|
|
1.039
|
OK
|
Fire Escape Staircase - Tread Width |
Mt. |
0.250
|
|
0.254
|
OK
|
Fire Escape Staircase - Riser Height |
Mt. |
|
0.200
|
-
|
OK
|
Fire Escape Staircase - Riser No. On Flight |
No. |
|
16
|
-
|
OK
|
Fire Escape Staircase - Cabin Ht. |
Mt. |
-
|
-
|
-
|
OK
|
|
|
[-] Rules
Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
|
Plot Width |
The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
|
Plot Depth |
The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
|
Plot Frontage |
The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
|
Common Plot |
; ;
|
Building Level |
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3)
The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
(4)
o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Below GL Floor Height |
,
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4)
; No Rule Defined
(5)
Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(6)
; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
|
Block Level |
Another Floor Check |
Mezzanine floor may be permitted above any floor in all types of buildings up to an extent of one-third of the actual covered area of that floor {As per Rule No. 47}
|
Building Level (Rooms) |
|
|
|
[-] Disclaimer:
AutoDCR is an input based Software Tool used by Municipal Corporations but the final Approval lies with concerned Officer/Authority. |
The generated Report is subjected to the following manual verification done by the Officials. |
1. |
The results of this Report is to be considered correct only if inputs given to the system in terms of Drawing or Data are correct.
|
2. |
This is a system generated Report so results will be totally dependent upon manual operations.
|
3. |
The road acquisition, Internal Road, Existing Road, Reservation, Amenity and all other areas to be deducted from the Plot area are checked with the sanctioned Layout of DP and verified that the same area are drawn in Drawing required as per System.
|
4. |
The shape, size and dimension of the Plot drawn into Drawing are verified with the demarcation plan and actual site condition.
|
5. |
The minimum Plot area considered for calculation in AutoDCR is verified with all the Documental areas.
|
6. |
The FAR Poly, Terrace poly and all other entities drawn in Drawing is checked as it is used to verify margins. FAR, Coverage and Parking calculations.
|
7. |
The report is checked for all failed entities by AE or JE.
|
|
|