No Image Found   

Check List Report

Adityapur Municipal Corporation

Version Number: 1.0.53  
Version Date: 16/10/2020 
Report Generated On: 08-02-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityADITYAPUR MUNICIPAL CORPORATION
Inward_NoAMC/BP/0076/W04/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageASANGI
Taluka16
Architect Details
Architect NameAnoop Kumar
License No.AMC/ENG/0024/2016
Architect AddressFlat No.- 204,Heaven palace , Behind M P Tower , Adityapur-1
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No385,386 & 818
NorthRoad Width - 6.10 MTR WIDE
SouthPlot No. - VACANT PLOT
EastPlot No. - SOCIETY PLOT NO- 22
WestRoad Width - 3.66 MTR WIDE
Owner's Details
NameNAGENDRA PRASAD
AddressQR NO- 33 /1-4 RAOD NO- 12, ADITYAPUR-2
Email IDravim76@gmail.com
Mobile No7979902689
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 269.14
2 Plot area as per Document by Applicant 269.14
3 Physical area measured at site 269.14
4 Area as per Site Visit (Site Visit Report) 269.14
5Area as per Drawing 268.55

Area of Plot Considered : 268.55

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 268.55
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 268.55
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 223.82
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 44.72
44.72
Balance Plot Area 223.82

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 161.13
Proposed Coverage Area ( 52.29 % ) 140.42
Total Prop. Coverage Area ( 52.29 % ) 140.42
Balance coverage area ( 7.71 % ) 20.71
FAR CHECK
Perm. FAR Area ( 2.50 ) 671.38
Total Perm. FAR area 671.38
Residential FAR 474.88
Proposed FAR Area 486.14
Total Proposed FAR Area 486.14
Consumed FAR (Factor) 1.81
Balance FAR Area 185.24
BUA CHECK
Total Proposed BuiltUp Area 587.75


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0.001 -
Plot size (as per measurement) 269.14 268.55
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 268.55 OK
Plot Width Mt. - - 17.33 OK
Plot Depth Mt. - - 15.49 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 15.95 OK
Coverage Area Sq.Mt. - 161.13 140.42 OK
FAR Area Sq.Mt. - 671.38 486.14 OK
Consumed FAR Sq.Mt. - 2.50 1.81 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 13.43 44.72 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 44.72 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.18 OK
Tree Cover (Plantation) - Angle Degree - 78.67 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 11 OK
A-1 (NAGENDRA PRASAD) Front Margin... 6.10 MTR WIDE MAIN ROAD Access Road Mt. 3.00 - 3.07 OK
Rear Margin Mt. 1.80 - 1.84 OK
Side1 Margin Mt. 1.50 - 1.52 OK
Side2 Margin Mt. 1.50 - 1.52 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (NAGENDRA PRASAD) Height Mt. 12.22 11.55 OK
A (NAGENDRA PRASAD) Third Floor - Height Mt. 2.75 - 2.90 OK
Third Floor - Clear Height Mt. 2.75 - 2.79 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.64 OK
Second Floor - Height Mt. 2.75 - 2.90 OK
Second Floor - Clear Height Mt. 2.75 - 2.79 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.64 OK
First Floor - Height Mt. 2.75 - 2.90 OK
First Floor - Clear Height Mt. 2.75 - 2.79 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.64 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.77 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.64 OK
Plinth - Height Mt. 0.45 - 0.55 OK
Plinth - Clear Height Mt. - - 0.55 OK
Plinth - Beam Clear Height Mt. - - 0.55 OK
A (NAGENDRA PRASAD) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (NAGENDRA PRASAD) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.112 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2 & 3 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.112 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 0.145 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.112 OK
STAIRCASE - Tread Width Mt. - 0.307 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.440 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.72 OK
Width Mt. - - 0.81 OK
Depth Mt. - - 0.89 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.73 OK
Width Mt. - - 0.72 OK
Depth Mt. - - 1.01 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.10 OK
Width Mt. - - 0.41 OK
Depth Mt. - - 2.67 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.66 OK
Width Mt. - - 0.66 OK
Depth Mt. - - 0.99 OK
Height Mt. - - - OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)