General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityADITYAPUR MUNICIPAL CORPORATION
Inward_NoAMC/BP/0076/W04/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageASANGI
Taluka16
Architect Details
Architect NameAnoop Kumar
License No.AMC/ENG/0024/2016
Architect AddressFlat No.- 204,Heaven palace , Behind M P Tower , Adityapur-1
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No385,386 & 818
NorthRoad Width - 6.10 MTR WIDE
SouthPlot No. - VACANT PLOT
EastPlot No. - SOCIETY PLOT NO- 22
WestRoad Width - 3.66 MTR WIDE
Owner's Details
NameNAGENDRA PRASAD
AddressQR NO- 33 /1-4 RAOD NO- 12, ADITYAPUR-2
Email IDravim76@gmail.com
Mobile No7979902689
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 269.14
2 Plot area as per Document by Applicant 269.14
3 Physical area measured at site 269.14
4 Area as per Site Visit (Site Visit Report) 269.14
5Area as per Drawing 268.55

Area of Plot Considered : 268.55

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 268.55
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 268.55
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 225.25
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 43.30
43.30
Balance Plot Area 225.25

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 161.13
Proposed Coverage Area ( 55.52 % ) 149.11
Total Prop. Coverage Area ( 55.52 % ) 149.11
Balance coverage area ( 4.48 % ) 12.02
FAR CHECK
Perm. FAR Area ( 2.50 ) 671.38
Total Perm. FAR area 671.38
Residential FAR 476.27
Proposed FAR Area 487.52
Total Proposed FAR Area 487.52
Consumed FAR (Factor) 1.82
Balance FAR Area 183.86
BUA CHECK
Total Proposed BuiltUp Area 596.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0.001 -
Plot size (as per measurement) 269.14 268.55
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 13.43 43.30 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 43.30 0.00 0.00 - 3.10 - 78.67 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (NAGENDRA PRASAD) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (NAGENDRA PRASAD) 11.67 11.85 11.85 11.85 Failed


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (NAGENDRA PRASAD) Third Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.74 OK
Second Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.74 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.74 OK
Ground Floor 2.75 - 2.85 2.75 - 2.77 2.40 - 2.64 OK
Plinth 0.45 - 0.55 - - 0.55 - - 0.55 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (NAGENDRA PRASAD) Terrace Floor 1.00 1.20 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (NAGENDRA PRASAD) G + 4 4 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
161.13 149.11 OK
60% 55.52%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (NAGENDRA PRASAD) - 149.11
  Total Prop. Coverage Area - 149.11
  Total Coverage Area 161.13 149.11

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (NAGENDRA PRASAD) 1 596.44 108.91 476.27 11.26 487.53 487.53 01
Grand Total : 1 596.44 108.91 476.27 11.26 487.53 487.53 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (NAGENDRA PRASAD)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 149.11 40.20 149.11 40.20
First Floor 149.11 149.11 149.11 149.11
Second Floor 149.11 149.11 149.11 149.11
Third Floor 149.11 149.11 149.11 149.11
Terrace Floor 0.00 0.00 0.00 0.00
Total : 596.44 487.53 596.44 487.53


[-] UnitBUA Table for Building :A (NAGENDRA PRASAD)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 408.21 408.10 3 1
TYPICAL - 1, 2 & 3 FLOOR PLAN SPLIT A FLAT 0.00 0.00 11 0
Total: - - 408.21 408.10 36 1


[-] Building :A (NAGENDRA PRASAD)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 149.11 108.91 28.94 11.26 40.20 40.20 01
First Floor 149.11 0.00 149.11 0.00 149.11 149.11 00
Second Floor 149.11 0.00 149.11 0.00 149.11 149.11 00
Third Floor 149.11 0.00 149.11 0.00 149.11 149.11 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 596.44 108.91 476.27 11.26 487.53 487.53 01
Total Number of Same Buildings : 1
Total : 596.44 108.91 476.27 11.26 487.53 487.53 01
[-] Table 4c-2

  FAR Area
Building FAR Area:487.52
Existing FAR Area :0.00
Perm.
671.38
Prop.
487.52
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (NAGENDRA PRASAD) 6.10 MTR WIDE MAIN ROAD Access Road 3.00 2.52 1.80 1.59 1.50 1.51 1.50 1.52 Failed






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (NAGENDRA PRASAD)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (NAGENDRA PRASAD)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.112 0.250 0.307 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 1, 2 & 3 FLOOR PLAN STAIRCASE 0.900 1.112 0.250 0.307 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.112 - 0.307 - 0.000 - 0 - - 2.440 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.72 - - 0.81 - - 0.89 - - 0.00 OK
RAIN WATER HARVESTING - - 0.73 - - 0.72 - - 1.01 - - 0.00 OK
ENT.GATE - - 1.10 - - 0.41 - - 2.67 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.66 - - 0.66 - - 0.99 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (NAGENDRA PRASAD)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1, 2 & 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 268.55 OK
  Plot Width - 17.33 OK
  Plot Depth - 15.49 OK
  Access Width - 6.10 OK
  Plot Frontage - 15.95 OK
  Coverage Area 161.13 149.11 OK
  FAR Area
Bldg. FAR Area : 487.52
Sanctioned FAR Area :0.00
671.38 487.52 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)