-
No Image Found   

Detail Scrutiny Report

Adityapur Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 31-03-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityADITYAPUR MUNICIPAL CORPORATION
Inward_NoAMC/BP/0069/W10/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBHATIA
Taluka16
Architect Details
Architect NameSATISH KUMAR
License No.AMC/DFTMN/0005/2017
Architect AddressB.B. PLACE , HOLDING NO. - 181 , LANE NO. - 4 , BHUYADIH , JAMSHEDPUR
Architect EmailIDsrishti_designer@hotmail.com
Architect Mobile No9204750591
Plot Details
Plot Use Residential
Plot SubUse Other Residential Building
PlotNearbyReligiousStructure NA
Plot/SubPlot No368 ( OLD) , 1569 PART , 1577 PART ( NEW )
NorthRoad Width - 6.10
SouthCTS No. - MANOJ KUMAR DAS
EastCTS No. - ALLEY
WestCTS No. - M. B. DUTTA
Owner's Details
NameSHRI SHAILENDRA KUMAR LAL
Address1577 BHATIA BASTI , NEAR TITE , ADITYAPUR
Email IDravicollsu@gmail.com
Mobile No9031960144
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 222.60
2 Plot area as per Document by Applicant 222.60
3 Physical area measured at site 222.60
4 Area as per Site Visit (Site Visit Report) 222.60
5Area as per Drawing 222.96

Area of Plot Considered : 222.60

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
Plotplot
Plot OccupancyResidential
Plot SubUse Other Residential Building
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 222.60
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 222.60
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 202.17
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 20.43
20.43
Balance Plot Area 202.17

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 133.56
Proposed Coverage Area ( 58.49 % ) 130.20
Total Prop. Coverage Area ( 58.49 % ) 130.20
Balance coverage area ( 1.51 % ) 3.36
FAR CHECK
Perm. FAR Area ( 2.50 ) 556.50
Total Perm. FAR area 556.50
Residential FAR 380.91
Proposed FAR Area 395.93
Total Proposed FAR Area 395.93
Consumed FAR (Factor) 1.78
Balance FAR Area 160.57
BUA CHECK
Total Proposed BuiltUp Area 520.80


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0.001 -
Plot size (as per measurement) 222.6 222.96
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 11.13 20.43 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 20.43 0.00 0.00 - 1.69 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BUILDING) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BUILDING) 13.11 11.40 11.40 11.40 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BUILDING) Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Plinth 0.45 - 0.15 - - 0.15 - - 0.15 Failed


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (BUILDING) Terrace Floor 1.00 1.20 1.07 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BUILDING) G + 4 4 - 6 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
133.56 130.20 OK
60% 58.49%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BUILDING) - 130.20
  Total Prop. Coverage Area - 130.20
  Total Coverage Area 133.56 130.20

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
A (BUILDING) 1 520.80 9.69 115.18 380.91 11.79 395.93 395.93 06
Grand Total : 1 520.80 9.69 115.18 380.91 11.79 395.93 395.93 06


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 130.20 15.02 130.20 15.02
First Floor 130.20 126.97 130.20 126.97
Second Floor 130.20 126.97 130.20 126.97
Third Floor 130.20 126.97 130.20 126.97
Terrace Floor 0.00 0.00 0.00 0.00
Total : 520.80 395.93 520.80 395.93


[-] UnitBUA Table for Building :A (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
TYPICAL - 1, 2& 3 FLOOR PLAN unit-1 FLAT 52.07 44.73 6 6
unit-2 FLAT 62.12 53.57 7
Total: - - 342.56 294.88 39 6


[-] Building :A (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Parking Resi. Stair
Ground Floor 130.20 0.00 115.18 0.00 11.79 15.02 15.02 00
First Floor 130.20 3.23 0.00 126.97 0.00 126.97 126.97 02
Second Floor 130.20 3.23 0.00 126.97 0.00 126.97 126.97 02
Third Floor 130.20 3.23 0.00 126.97 0.00 126.97 126.97 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 520.80 9.69 115.18 380.91 11.79 395.93 395.93 06
Total Number of Same Buildings : 1
Total : 520.80 9.69 115.18 380.91 11.79 395.93 395.93 06
[-] Table 4c-2

  FAR Area
Building FAR Area:395.93
Existing FAR Area :0.00
Perm.
556.50
Prop.
395.93
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BUILDING) 6.1 m wide road 3.00 3.96 1.80 1.80 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (BUILDING) 11.40 - 1 OK

[-] Lift Check Table

[-] For Building :A (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.70 1.90 1.90 OK
TYPICAL - 1, 2& 3 FLOOR PLAN Lift 1.70 1.70 1.90 1.90 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (BUILDING) Residential Residential Bldg/Apartment > 0 1 6.00 1.00 6 - - - - - - -
> 0 1 6.00 - - - - - - 1 6 -
> 0 1 6.00 - - - 1 1 - - - -
Total : - - - - 6 6 - 1 1 - 6 6

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 3 37.50 OK
Two Stack.Car - - 3 37.50 OK
Total Car 6 75.00 6 75.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 6 12.00 OK
Total TwoWheeler 6 12.00 6 12.00 OK
Other Parking - - - 65.18 OK
Total 99.50 189.18 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.266 0.200 0.143 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.267 - 0.000 - 0 - - 2.591 OK
TYPICAL - 1, 2& 3 FLOOR PLAN STAIRCASE 0.900 1.219 0.250 0.266 0.200 0.143 - 10 - - 0.000 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (BUILDING)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TERRACE FLOOR PLAN CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
TYPICAL - 1, 2& 3 FLOOR PLAN CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 0.20 - - 0.51 - - 0.51 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.20 - - 0.51 - - 0.51 - - 0.00 OK


   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BUILDING)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:TYPICAL - 1, 2& 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 222.60 OK
  Plot Width - 12.19 OK
  Plot Depth - 18.29 OK
  Access Width - 6.10 OK
  Plot Frontage - 12.19 OK
  Coverage Area 133.56 130.20 OK
  FAR Area
Bldg. FAR Area : 395.93
Sanctioned FAR Area :0.00
556.50 395.93 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt., for every 16 flats or upto G+4 floors, No Lift is reqd. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)