No Image Found   

Detail Scrutiny Report

Adityapur Municipal Corporation

Version Number: 1.0.46  
Version Date: 22/06/2020 
Report Generated On: 27-07-2020 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityADITYAPUR MUNICIPAL CORPORATION
Inward_NoAMC/BP/0017/W05/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDINDLI
Taluka16
Architect Details
Architect NameAbhishek Tewari
License No.AMC/ARC/0026/2016
Architect AddressPratiksha 23, Fortune City, Near Nit Adityapur 2, Jamshedpur, P.O. Industrial Area, Adityapur
Architect EmailIDabhitewari1984@gmail.com
Architect Mobile No8603677734
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1112,1113,1137
NorthPlot No. - 1173,1174
SouthRoad Width - 7.55
EastPlot No. - 1137,1114
WestRoad Width - 4
Owner's Details
NameJAGAVANTI ENTERPRISES PVT LTD REP BY DIRECTOR SHRI RITESH KUMAR SHUKLA
Address502,3RD FLOOR ,MAHAVEER TRADE CENTER, NEW TEACHER ,TRAINING MORE, BARA GAMHARAIA,GAMHARIA,DIST-SERAIKELA KHARSAWAN
Email IDrkshuklajsr@gmail.com
Mobile No9431112675
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1943.19
2 Plot area as per Document by Applicant 1943.19
3 Physical area measured at site 1943.19
4 Area as per Site Visit (Site Visit Report) 1943.19
5Area as per Drawing 1943.19

Area of Plot Considered : 1943.19

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeNA
Gross Plot Area 1943.19
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1943.19
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1123.42
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 819.77
819.77
Balance Plot Area 1123.42

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 971.59
Proposed Coverage Area ( 29.91 % ) 581.27
Total Prop. Coverage Area ( 29.91 % ) 581.27
Balance coverage area ( 20.09 % ) 390.32
FAR CHECK
Perm. FAR Area ( 2.50 ) 4857.97
Total Perm. FAR area 4857.97
Residential FAR 2798.98
Proposed FAR Area 2820.55
Total Proposed FAR Area 2820.55
Consumed FAR (Factor) 1.45
Balance FAR Area 2037.42
BUA CHECK
Total Proposed BuiltUp Area 3542.88


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 7.55 7.55
Proposed Road Width as per Master Plan 7.55 -
Road Widening Width 0.001 -
Plot size (as per measurement) 1943.19 1943.19
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 194.32 819.77 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Normal Open Space - 213.36 0.00 0.00 - 7.65 - 87.64 No Access Provided OK
Tree Cover (Plantation) - 606.40 0.00 0.00 - 22.91 - 87.73 4m wide MAINROAD Access Road OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 46 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SHD) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SHD) 17.38 14.90 15.18 14.90 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SHD) Fourth Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.65 OK
Basement Floor 2.40 - 2.50 2.40 - 2.40 2.10 - 2.30 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SHD) Terrace Floor 1.00 1.20 1.05 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (SHD) Basement Floor - 0.37 - 583.93 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (SHD) - 583.93
Total - 583.93 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (SHD)   7.55m wide MAINROAD 3.00 6.05 3.00 35.36 2.00 2.73 2.00 2.52 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SHD) G + 5 5 - 30 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (SHD) 2 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
971.59 581.27 OK
50% 29.91%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SHD) - 581.27
  Total Prop. Coverage Area - 581.27
  Total Coverage Area 971.59 581.27

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Void Parking Resi. Stair
A (SHD) 1 3542.88 35.15 17.68 114.15 555.33 2799.00 21.56 2820.56 2820.56 30
Grand Total : 1 3542.88 35.15 17.68 114.15 555.33 2799.00 21.56 2820.56 2820.56 30


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SHD)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 583.93 21.56 583.93 21.56
Ground Floor 581.27 558.44 581.27 558.44
First Floor 594.42 560.14 594.42 560.14
Second Floor 594.42 560.14 594.42 560.14
Third Floor 594.42 560.14 594.42 560.14
Fourth Floor 594.42 560.14 594.42 560.14
Terrace Floor 0.00 0.00 0.00 0.00
Total : 3542.88 2820.56 3542.88 2820.56


[-] UnitBUA Table for Building :A (SHD)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN FLAT-G1 FLAT 93.43 93.05 10 6
FLAT-G2 FLAT 68.15 67.61 6
FLAT-G3 FLAT 68.39 68.24 6
FLAT-G4 FLAT 66.73 66.43 6
FLAT-G5 FLAT 91.58 91.18 9
FLAT-G6 FLAT 64.23 63.89 7
TYPICAL - 1, 2, 3, 4 FLOOR PLAN FLAT-T1 FLAT 93.43 92.58 10 24
FLAT-T2 FLAT 68.15 67.84 6
FLAT-T3 FLAT 68.39 68.20 6
FLAT-T4 FLAT 66.73 66.39 6
FLAT-T5 FLAT 89.59 89.20 9
FLAT-T6 FLAT 61.86 61.53 7
Total: - - 2245.09 2233.39 220 30


[-] Building :A (SHD)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Void Parking Resi. Stair
Basement Floor 583.93 7.03 0.00 0.00 555.33 0.00 21.56 21.56 21.56 00
Ground Floor 581.27 0.00 0.00 22.83 0.00 558.44 0.00 558.44 558.44 06
First Floor 594.42 7.03 4.42 22.83 0.00 560.14 0.00 560.14 560.14 06
Second Floor 594.42 7.03 4.42 22.83 0.00 560.14 0.00 560.14 560.14 06
Third Floor 594.42 7.03 4.42 22.83 0.00 560.14 0.00 560.14 560.14 06
Fourth Floor 594.42 7.03 4.42 22.83 0.00 560.14 0.00 560.14 560.14 06
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 3542.88 35.15 17.68 114.15 555.33 2799.00 21.56 2820.56 2820.56 30
Total Number of Same Buildings : 1
Total : 3542.88 35.15 17.68 114.15 555.33 2799.00 21.56 2820.56 2820.56 30
[-] Table 4c-2

  FAR Area
Building FAR Area:2820.55
Existing FAR Area :0.00
Perm.
4857.97
Prop.
2820.55
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SHD) 7.55m wide MAINROAD 6.00 6.05 5.00 35.36 2.00 2.73 2.00 2.52 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SHD)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 1, 2, 3, 4 FLOOR PLAN BALCONY 1.20 1.20 OK
BALCONY 1.20 1.20 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Passage Details

[-] For Building :A (SHD)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 1.53 mt. Wide Passage 34.67 1.00 1.53 - 21.85 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN 1.53 mt. Wide Passage 34.47 1.00 1.64 - 21.73 OK

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (SHD) 14.90 - 2 OK

[-] Lift Check Table

[-] For Building :A (SHD)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.79 1.90 1.96 OK
Lift 1.70 1.79 1.90 1.96 OK
GROUND FLOOR PLAN Lift 1.70 1.79 1.90 1.96 OK
Lift 1.70 1.79 1.90 1.96 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN Lift 1.70 1.79 1.90 1.96 OK
Lift 1.70 1.79 1.90 1.96 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.79 1.90 1.96 OK
Lift Machine Room 1.70 1.79 1.90 1.96 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SHD) Residential Residential Bldg/Apartment > 0 1 30.00 1.00 30 - - - - - - -
> 0 1 30.00 - - - - - - 1 30 -
> 0 1 30.00 - - - 1 3 - - - -
Total : - - - - 30 30 - 3 3 - 30 30

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 30 375.00 OK
Total Car 30 375.00 30 375.00 OK
Visitor's Car Parking - - 3 37.50 OK
Total Visitor Parking 3 37.50 3 37.50 OK
TwoWheeler - - 30 60.00 OK
Total TwoWheeler 30 60.00 30 60.00 OK
Other Parking - - - 199.33 OK
Total 472.50 769.33 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SHD)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.178 - 8 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.158 - 9 - - 0.000 OK
TYPICAL - 1, 2, 3, 4 FLOOR PLAN STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.178 - 8 - - 0.000 OK
STAIRCASE 0.900 1.220 0.250 0.267 0.200 0.158 - 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.220 - 0.267 - 0.000 - 0 - - 3.381 OK
STAIRCASE - 1.220 - 0.267 - 0.000 - 0 - - 3.381 OK

In A-1 (SHD) Bldg in , STAIRCASE shall not be permitted in less than 3.mt. marginal open space

In A-1 (SHD) Bldg in , STAIRCASE shall not be permitted in less than 3.mt. marginal open space

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
5.10 mt. long .66 mt. High 3.00 mt. Wide Natural Slope - 3.60 - 0.66 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SHD) BASEMENT FLOOR PLAN 1 1 OK

   
   
[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (SHD)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TYPICAL - 1, 2, 3, 4 FLOOR PLAN C.B. 0.60 0.56 - 1.53 - 0.85 OK
C.B. 0.60 0.56 - 1.56 - 0.87 OK
C.B. 0.60 0.56 - 1.75 - 0.98 OK
C.B. 0.60 0.56 - 1.64 - 0.92 OK
C.B. 0.60 0.59 - 1.53 - 0.90 OK
C.B. 0.60 0.59 - 1.30 - 0.76 OK
C.B. 0.60 0.56 - 1.53 - 0.85 OK
C.B. 0.60 0.59 - 2.94 - 1.73 OK
C.B. 0.60 0.56 - 1.45 - 0.81 OK
C.B. 0.60 0.54 - 1.64 - 0.88 OK
   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 3.10 - - 1.32 - - 2.35 - - 0.00 OK
Sewage Treatment Plant - - 0.98 - - 0.74 - - 1.32 - - 0.00 OK
RAIN WATER HARVESTING - - 3.10 - - 1.32 - - 2.35 - - 0.00 OK
Overhead WaterTank - - 17.83 - - 3.05 - - 5.84 - - 0.00 OK
Overhead WaterTank - - 12.79 - - 2.93 - - 4.37 - - 0.00 OK
ENT.GATE - - 1.21 - - 0.58 - - 2.48 - - 0.00 OK
ENT.GATE - - 1.47 - - 0.56 - - 2.64 - - 0.00 OK
SOLAR HEATING SYSTEM - - 3.10 - - 1.32 - - 2.35 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SHD) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 2 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SHD)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1, 2, 3, 4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 1943.19 OK
  Plot Width - 19.29 OK
  Plot Depth - 100.75 OK
  Access Width 6.10 7.55 OK
  Plot Frontage - 16.01 OK
  Coverage Area 971.59 581.27 OK
  FAR Area
Bldg. FAR Area : 2820.55
Sanctioned FAR Area :0.00
4857.97 2820.55 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Adityapur Nagar Parishad, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 45 mt. or above and Plot width 15-21 mt., Margin required in Front shall be 6.0 mt., Rear 5.0 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed on first floor subject to condition that the side and rear setback of the Building is more than 4.5 mt. and 4.5m. clear driveway is available for Fire movement. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) -
(8) No need to check distance from Building Overhead WaterTank
(9) No need to check distance from Building ENT.GATE
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)