No Image Found   

Failed List Report

Adityapur Municipal Corporation

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 21-07-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityADITYAPUR MUNICIPAL CORPORATION
Inward_NoAMC/BP/0081/W18/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageADITYAPUR BAZAR
Taluka16
Architect Details
Architect NameANOOP KUMAR
License No.AMC/ENG/0024/2016
Architect AddressFLAT NO :- 204, HEAVEN PALACE, BEHIND M.P. TOWER, NEAR BANK OF BARODA, ADITYAPUR , JAMSHEDPUR, JHARKHAND
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No5, 6, 7a, 7b ,8
North -
SouthRoad Width - 6 MTR WIDE SIDE ROAD
East -
WestRoad Width - 15.10 MTR WIDE MAIN ROAD
Owner's Details
NameMR RAMESH KUMAR KEDIA
AddressBARA GAMHARIA , P.O & P.S- ADITYAPUR, JAMSHEDPUR
Email IDravim76@gmail.com
Mobile No7903326403
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 2855.03
2 Plot area as per Document by Applicant 2855.03
3 Physical area measured at site 2855.03
4 Area as per Site Visit (Site Visit Report) 2855.03
5Area as per Drawing 2847.80

Area of Plot Considered : 2847.80

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 2847.80
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 2847.80
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2513.35
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 334.45
334.45
Balance Plot Area 2513.35

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1423.90
Proposed Coverage Area ( 38.44 % ) 1094.79
Total Prop. Coverage Area ( 38.44 % ) 1094.79
Balance coverage area ( 11.56 % ) 329.11
FAR CHECK
Perm. FAR Area ( 2.50 ) 7119.50
Total Perm. FAR area 7119.50
Commercial FAR 6573.69
Proposed FAR Area 6600.35
Total Proposed FAR Area 6600.35
Consumed FAR (Factor) 2.32
Balance FAR Area 519.15
BUA CHECK
Total Proposed BuiltUp Area 12392.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 15.1 15.10
Proposed Road Width as per Master Plan 15.1 -
Road Widening Width 0.01 -
Plot size (as per measurement) 2855.03 2847.80
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Adityapur Nagar Parishad, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For Adityapur Nagar Parishad, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area above 2000 sq.mt., The minimum width or driveways should not be less than 4.50 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 23.10-30.0 mt.,Margin required in Front shall be 8.0 mt., Rear 5.0 mt. and 5.0 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(5) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(6) The lift shall have a minimum width 1.8 mt. and minimum depth 3.0 mt.{As per clause no 4 and page no. 14 NBC }
(7) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(8) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(9) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
(5) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp (1) For parking spaces in basements and upper storey of parking floors,if car parking is more then 40, two ramp of minimum of 3.30m width if it is strait and 3.6m width if it is curved at any point, or one ramp of minimum 5.4 m width and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided. For height more than 2.4m,slope shall not exceed 1:20. {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) ; No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is more then 500sq.mt.,atleast two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved or one ramp of minimum 5.4m width shall be provided
Plot / Building Level
Accessory Use (1) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(2) No need to check distance from Building TRANSFORMER
(3) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(4) No need to check distance from Building Toilet
(5) -
(6) No need to check distance from Building Sewage Treatment Plant
(7) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(8) No need to check distance from Building RAIN WATER HARVESTING
(9) No need to check distance from Building ENT.GATE
(10) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(11) No need to check distance from Building GUARD ROOM
(12) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(13) No need to check distance from Building Entrance Lobby
(14) -
(15) No need to check distance from Building SOLAR HEATING SYSTEM
(16) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(17) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)