Report Generated On: 01-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District BOKARO
Authority CHAS MUNICIPAL CORPORATION
Inward_No CMC/BP/0125/W07/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Chas
Taluka 17
Architect Details
Architect Name Trilochan Kumar Trivedi
License No. CMC/SUP/0003/2017
Architect Address DSP Colony, Near Chas Municipal Ccorporation, Post-Chas, Dist Bokaro
Architect EmailID tktrivedi1@rediffmail.com
Architect Mobile No 9955080822
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 3289
North Plot No. - 3280
South CTS No. - G/1 MARK LAND
East Plot No. - 3268
West Plot No. - 4.57 M ROAD
Owner's Details
Name PARWATI DEVI
Address SHIV SHAKTI NAGAR CHAS BOKARO
Email ID parwatidevi121258@gmail.com
Mobile No 9800003539
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 242.89
2 Plot area as per Document by Applicant 242.89
3 Physical area measured at site 242.89
4 Area as per Site Visit (Site Visit Report) 242.89
5 Area as per Drawing 242.29

Area of Plot Considered : 242.29

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 242.29
Deduction from Gross Plot area
- Road Widening Area 22.77
22.77
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 219.52
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 194.82
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 22.77
- Common Plot 24.70
47.47
Balance Plot Area 194.82

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 153.66
Proposed Coverage Area ( 43.52 % ) 95.53
Total Prop. Coverage Area ( 43.52 % ) 95.53
Balance coverage area ( 26.48 % ) 58.13
FAR CHECK
Perm. FAR Area ( 1.20 ) 263.42
Total Perm. FAR area 263.42
Residential FAR 95.53
Proposed FAR Area 95.53
Total Proposed FAR Area 95.53
Consumed FAR (Factor) 0.44
Balance FAR Area 167.89
BUA CHECK
Total Proposed BuiltUp Area 95.53


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 3 3.00
Proposed Road Width as per Master Plan 3 -
Road Widening Width 0 1.51
Plot size (as per measurement) 242.89 242.29





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth less than 3.60 mt., the Floor Area Ratio-FAR shall be 1.2 {As per Rule No.39, Table 15, Note i}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road upto 50 mt. shall be 3.6 mt. {As per Rule No. 34 Table No. 6}
Building Level
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width upto 3.6 mt. only G+1 floors shall be allowed {As per Rule No. 39.1 Note 1}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Garbage Pit
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)