General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0205/W19/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChas
Taluka17
Architect Details
Architect NameSuresh Prasad Singh
License No.CMC/ENG/0002/2017
Architect Address414, Sector III D,Steel City Bokaro
Architect EmailIDsinghsp.2014@rediffmail.com
Architect Mobile No7856089135
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No5290
NorthRoad Width - 6.00 M WIDE ROAD
SouthCTS No. - AWANTI KANT ROY
EastRoad Width - 3.05 M WIDE ROAD
WestCTS No. - ROAD
Owner's Details
NameVIKASH KUMAR AND RAVI SHANKAR
AddressASHOK VATIKA COLONY CHAS BOKARO
Email IDmbtbuilders16@gmail.com
Mobile No7004455752
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 637.61
2 Plot area as per Document by Applicant 637.61
3 Physical area measured at site 637.61
4 Area as per Site Visit (Site Visit Report) 637.61
5Area as per Drawing 618.70

Area of Plot Considered : 618.70

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 618.70
Deduction from Gross Plot area
- Surrender Free of Cost 16.19
16.19
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 602.52
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 524.01
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 16.19
- Common Plot 78.50
94.69
Balance Plot Area 524.01

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 361.51
Proposed Coverage Area ( 51.88 % ) 312.58
Total Prop. Coverage Area ( 51.88 % ) 312.58
Balance coverage area ( 8.12 % ) 48.93
FAR CHECK
Perm. FAR Area ( 2.50 ) 1546.75
Total Perm. FAR area 1546.75
Residential FAR 1301.61
Proposed FAR Area 1314.48
Total Proposed FAR Area 1314.48
Consumed FAR (Factor) 2.12
Balance FAR Area 232.27
BUA CHECK
Total Proposed BuiltUp Area 1670.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 0.76
Plot size (as per measurement) 637.61 618.70



[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 60.25 78.50 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Access Status
Reqd Prop
Normal Open Space - 16.49 No Access Provided OK
Normal Open Space - 62.01 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 11 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A1 (RESIDENTIAL) Residential Residential Bldg/Apartment Non-Highrise


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A1 (RESIDENTIAL) 14.45 13.35 13.35 13.35 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A1 (RESIDENTIAL) Fourth Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Stilt Floor - - 2.85 2.40 - 2.75 2.10 - 2.40 OK
Plinth - - 0.45 - - 0.35 - - 0.35 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A1 (RESIDENTIAL) Terrace Floor 1.00 1.20 1.00 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A1 (RESIDENTIAL) P + 4 5 - 12 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
361.51 312.58 OK
60% 51.88%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A1-1 (RESIDENTIAL) - 312.58
Total Prop. Coverage Area - 312.58
Total Coverage Area 361.51 312.58

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi. Stair
A1 (RESIDENTIAL) 1 1670.24 13.32 42.72 299.71 1301.62 9.54 1314.49 1314.49 12
Grand Total : 1 1670.24 13.32 42.72 299.71 1301.62 9.54 1314.49 1314.49 12


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A1 (RESIDENTIAL)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Stilt Floor 312.58 12.87 312.58 12.87
First Floor 312.58 309.25 312.58 309.25
Second Floor 348.36 330.79 348.36 330.79
Third Floor 348.36 330.79 348.36 330.79
Fourth Floor 348.36 330.79 348.36 330.79
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1670.24 1314.49 1670.24 1314.49


[-] UnitBUA Table for Building :A1 (RESIDENTIAL) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN FLAT-101 FLAT 99.17 98.92 9 3
FLAT-102 FLAT 101.57 101.11 9
FLAT-103 FLAT 84.61 84.20 9
TYPICAL - 2, 3& 4 FLOOR PLAN FLAT-201,301,401 FLAT 110.47 110.23 9 9
FLAT-202,302,402 FLAT 110.61 110.14 10
FLAT-204,304,404 FLAT 92.74 92.34 9
Total: - - 1226.82 1222.38 111 12


[-] Building :A1 (RESIDENTIAL)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Parking Resi. Stair
Stilt Floor 312.58 0.00 0.00 299.71 0.00 9.54 12.87 12.87 00
First Floor 312.58 3.33 0.00 0.00 309.25 0.00 309.25 309.25 03
Second Floor 348.36 3.33 14.24 0.00 330.79 0.00 330.79 330.79 03
Third Floor 348.36 3.33 14.24 0.00 330.79 0.00 330.79 330.79 03
Fourth Floor 348.36 3.33 14.24 0.00 330.79 0.00 330.79 330.79 03
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1670.24 13.32 42.72 299.71 1301.62 9.54 1314.49 1314.49 12
Total Number of Same Buildings : 1
Total : 1670.24 13.32 42.72 299.71 1301.62 9.54 1314.49 1314.49 12
[-] Table 4c-2

FARArea
Building FAR Area:1314.48
Existing FAR Area :0.00
Perm.
1546.75
Prop.
1314.48
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A1-1 (RESIDENTIAL) ROAD WIDENING AREA(SURRENDERED FREE OF COST) 4.00 4.53 3.50 4.07 2.00 2.03 2.00 2.03 OK






[-] Inner Building Details (Table 6)

[-] Balcony Details (Table 6c)

[-] For Building:A1 (RESIDENTIAL)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 2, 3& 4 FLOOR PLAN BALCONY 1.20 0.28 OK
BALCONY 1.20 0.90 OK
BALCONY 0.90 0.82 OK
BALCONY 0.90 0.87 OK
BALCONY 0.90 0.87 OK
BALCONY 0.90 0.87 OK
BALCONY 0.90 0.86 OK
BALCONY 1.20 0.06 OK
BALCONY 0.90 0.85 OK
BALCONY 1.20 0.21 OK
BALCONY 0.90 0.81 OK
BALCONY 0.90 0.49 OK



For PWork At Layout:

No Balcony Found.


[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A1 (RESIDENTIAL) 13.35 1 1 OK

[-] Lift Check Table

[-] For Building :A1 (RESIDENTIAL)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
STILT FLOOR PLAN Lift 1.70 1.73 1.90 1.93 OK
FIRST FLOOR PLAN Lift 1.70 1.73 1.90 1.93 OK
TYPICAL - 2, 3& 4 FLOOR PLAN Lift 1.70 1.73 1.90 1.93 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.73 1.90 3.30 OK



[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A1 (RESIDENTIAL) Residential Residential Bldg/Apartment > 0 1 12.00 1.00 12 - - - - - - -
> 0 1 12.00 - - - - - - 1 12 -
> 0 1 12.00 - - - 1 2 - - - -
Total : - - - - 12 12 - 2 2 - 12 11

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 12 150.00 OK
Total Car 12 150.00 12 150.00 OK
Visitor's Car Parking 2 25.00 2 25.00 OK
TwoWheeler - - 11 26.51 OK
Total TwoWheeler 12 24.00 11 26.51 OK
Other Parking - - - 98.21 OK
Total 199.00 326.23 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A1 (RESIDENTIAL)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
STILT FLOOR PLAN STAIRCASE 0.900 1.143 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.143 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 2, 3& 4 FLOOR PLAN STAIRCASE 0.900 1.143 0.250 0.254 0.200 0.143 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.143 - 0.254 - 0.000 - 0 - - 1.550 OK


[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A1 (RESIDENTIAL)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
TYPICAL - 2, 3& 4 FLOOR PLAN C.B. 0.60 0.60 - 2.74 - 1.64 OK
C.B. 0.60 0.60 - 1.68 - 1.01 OK
C.B. 0.60 0.60 - 1.68 - 1.01 OK
C.B. 0.60 0.60 - 1.68 - 1.01 OK
C.B. 0.60 0.60 - 1.80 - 1.08 OK
C.B. 0.60 0.60 - 2.59 - 1.55 OK

[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 15.11 - - 2.10 - - 7.19 - - 0.00 OK
ENT.GATE - - 3.18 - - 0.52 - - 6.19 - - 0.00 OK
SOLAR HEATING SYSTEM - - 28.65 - - 3.18 - - 9.02 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A1 (RESIDENTIAL) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK


[-] Floor Details (Table 9)


[-] Building:A1 (RESIDENTIAL)


[-] Floor:STILT FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 2, 3& 4 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.




[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 602.52 OK
Plot Width - 18.73 OK
Plot Depth - 32.17 OK
Access Width 6.10 6.10 OK
Plot Frontage - 21.34 OK
Coverage Area 361.51 312.58 OK
FARArea
Bldg. FAR Area : 1314.48
Sanctioned FAR Area :0.00
1546.75 1314.48 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ;
(2) ;
(3) ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width 15-21 mt., Margin required in Front shall be 4.0 mt., Rear 3.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
(4) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
(2) Projected balcony shall be allowed with a width of 0.9 meters where the setback is between 2.0 meters to 2.5 meters {As per Rule No. 46.4}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Cupboard up to 0.60 mt. in width shall be permitted. {As per Rule 6.26.1 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)