-
No Image Found   

Detail Scrutiny Report

Chas Municipal Corporation

Version Number: 1.0.53  
Version Date: 16/10/2020 
Report Generated On: 19-01-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0164/W02/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChas
Taluka17
Architect Details
Architect NameMOHAMMED AZIZULLAH
License No.CMC/ARC/0006/2018
Architect AddressSABA ASSOCIATES, PLOT NO:F/14, CITY CENTER, SECTOR-4, BOKARO STEEL CITY
Architect EmailIDar.mdazizullah@gmail.com
Architect Mobile No8792249657
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No594,595,601
NorthRoad Width - 5.48
SouthPlot No. - mihir jha
EastPlot No. - 601
WestRoad Width - 6.10
Owner's Details
NameSHREE NARAYAN CONSTRUCTION ON BEHALF RAMESH KUMAR SINGH
AddressSHOP N-S/1,JAGIDESH PALACE, NAUVATOLI, NEAR PAHARI MANDIR, RANCHI,JHARKHAND
Email IDrameshkumarsingh133@gmail.com
Mobile No7979892519
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 485.62
2 Plot area as per Document by Applicant 485.62
3 Physical area measured at site 485.62
4 Area as per Site Visit (Site Visit Report) 455.95
5Area as per Drawing 454.43

Area of Plot Considered : 454.43

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 454.43
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 454.43
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 406.12
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 48.31
48.31
Balance Plot Area 406.12

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 272.66
Proposed Coverage Area ( 59.83 % ) 271.87
Total Prop. Coverage Area ( 59.83 % ) 271.87
Balance coverage area ( 0.17 % ) 0.79
FAR CHECK
Perm. FAR Area ( 2.50 ) 1136.07
Total Perm. FAR area 1136.07
Residential FAR 1106.99
Proposed FAR Area 1118.85
Total Proposed FAR Area 1118.85
Consumed FAR (Factor) 2.46
Balance FAR Area 17.22
BUA CHECK
Total Proposed BuiltUp Area 1402.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 455.95 454.43
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 45.44 48.31 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 48.31 0.00 0.00 - 3.01 - 89.95 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 11 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI NARAYAN) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI NARAYAN) 12.44 12.00 12.00 12.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI NARAYAN) Third Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.88 OK
Second Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.88 OK
First Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.88 OK
Ground Floor 2.75 - 3.00 2.75 - 2.88 2.40 - 2.88 OK
Basement Floor 2.40 - 3.00 2.40 - 2.88 2.10 - 2.88 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI NARAYAN) Terrace Floor 1.00 1.20 1.06 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (SRI NARAYAN) Basement Floor - 3.00 - 277.55 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (SRI NARAYAN) - 277.55
Total - 277.55 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (SRI NARAYAN)   6.10MTR WIDE ROAD 3.00 3.29 2.25 2.53 1.50 1.86 1.50 1.73 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI NARAYAN) G + 4 4 - 4 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (SRI NARAYAN) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
272.66 271.87 OK
60% 59.83%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRI NARAYAN) - 271.87
  Total Prop. Coverage Area - 271.87
  Total Coverage Area 272.66 271.87

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Balcony Parking Resi. Stair
A (SRI NARAYAN) 1 1415.26 12.66 1402.60 14.58 7.10 222.06 1107.00 11.86 1118.86 1118.86 04
Grand Total : 1 1415.26 12.66 1402.60 14.58 7.10 222.06 1107.00 11.86 1118.86 1118.86 04


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI NARAYAN)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 277.55 11.86 277.55 11.86
Ground Floor 271.87 271.87 271.87 271.87
First Floor 279.66 276.01 279.66 276.01
Second Floor 286.76 279.56 286.76 279.56
Third Floor 286.76 279.56 286.76 279.56
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1402.60 1118.86 1402.60 1118.86


[-] UnitBUA Table for Building :A (SRI NARAYAN)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN 2 FLAT 268.23 268.18 21 1
FIRST FLOOR PLAN 2A FLAT 276.01 275.96 21 1
TYPICAL - 2& 3 FLOOR PLAN 3A FLAT 283.11 275.96 21 2
Total: - - 1110.45 1096.05 84 4


[-] Building :A (SRI NARAYAN)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Balcony Parking Resi. Stair
Basement Floor 277.55 0.00 277.55 3.63 0.00 222.06 0.00 11.86 11.86 11.86 00
Ground Floor 280.87 9.00 271.87 0.00 0.00 0.00 271.87 0.00 271.87 271.87 01
First Floor 280.88 1.22 279.66 3.65 0.00 0.00 276.01 0.00 276.01 276.01 01
Second Floor 287.98 1.22 286.76 3.65 3.55 0.00 279.56 0.00 279.56 279.56 01
Third Floor 287.98 1.22 286.76 3.65 3.55 0.00 279.56 0.00 279.56 279.56 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1415.26 12.66 1402.60 14.58 7.10 222.06 1107.00 11.86 1118.86 1118.86 04
Total Number of Same Buildings : 1
Total : 1415.26 12.66 1402.60 14.58 7.10 222.06 1107.00 11.86 1118.86 1118.86 04
[-] Table 4c-2

  FAR Area
Building FAR Area:1118.85
Existing FAR Area :0.00
Perm.
1136.07
Prop.
1118.85
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI NARAYAN) 6.10MTR WIDE ROAD 3.00 3.29 2.25 2.31 1.50 1.86 1.50 1.73 OK






[-] Inner Building Details (Table 6)
   
   
[-] Balcony Details (Table 6c)

[-] For Building:A (SRI NARAYAN)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 2& 3 FLOOR PLAN BALCONY 1.20 0.90 OK
BALCONY 1.20 0.90 OK



For PWork At Layout : 

No Balcony Found.

   
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (SRI NARAYAN) 12.00 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (SRI NARAYAN)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
GROUND FLOOR PLAN Lift 1.70 1.80 1.90 2.03 OK
BASEMENT FLOOR PLAN Lift 1.70 1.80 1.90 2.02 OK
FIRST FLOOR PLAN Lift 1.70 1.80 1.90 2.03 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.80 1.90 2.03 OK
TYPICAL - 2& 3 FLOOR PLAN Lift 1.70 1.80 1.90 2.03 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (SRI NARAYAN) Residential Residential Bldg/Apartment > 0 1 4.00 1.00 4 - - - - - - -
> 0 1 4.00 - - - - - - 1 4 -
> 0 1 4.00 - - - 1 1 - - - -
Total : - - - - 4 8 - 1 0 - 4 4

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 8 100.00 OK
Total Car 4 50.00 8 100.00 OK
Total Visitor Parking 1 12.50 0 0.00 FAILED
TwoWheeler - - 4 8.00 OK
Total TwoWheeler 4 8.00 4 8.00 OK
Other Parking - - - 114.06 OK
Total 70.50 230.06 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Required Floor Level TW Parking Driveway of 3.00 mt. distance is not Provided at BASEMENT FLOOR PLAN In A (SRI NARAYAN).
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI NARAYAN)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.200 - 0.250 - 0.000 - 0 - - 2.525 OK
TYPICAL - 2& 3 FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
10.00 mt. long 1.50 mt. High 4.00 mt. Wide Natural Slope - 4.00 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SRI NARAYAN) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.85 - - 1.04 - - 2.75 - - 0.00 OK
RAIN WATER HARVESTING - - 3.20 - - 1.08 - - 2.96 - - 0.00 OK
ENT.GATE - - 3.88 - - 0.51 - - 7.62 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.97 - - 1.16 - - 2.57 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI NARAYAN) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRI NARAYAN)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 2& 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 454.43 OK
  Plot Width - 18.44 OK
  Plot Depth - 24.64 OK
  Access Width - 6.10 OK
  Plot Frontage - 18.29 OK
  Coverage Area 272.66 271.87 OK
  FAR Area
Bldg. FAR Area : 1118.85
Sanctioned FAR Area :0.00
1136.07 1118.85 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Floor Parking DriveWay Check The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)