No Image Found   

Detail Scrutiny Report

Chas Municipal Corporation

Version Number: 1.0.55  
Version Date: 16/10/2020 
Report Generated On: 24-06-2021 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0122/W07/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhawanipur
Taluka17
Architect Details
Architect NameSuresh Prasad Singh
License No.CMC/ENG/0002/2017
Architect Address414, Sector III D,Steel City Bokaro
Architect EmailIDsinghsp.2014@rediffmail.com
Architect Mobile No7970758220
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No223,231
NorthPlot No. - MAINA DEVI
SouthPlot No. - 223,231
EastRoad Width - NH 32
WestPlot No. - 221
Owner's Details
NameRAMAYAN RAM
AddressSOLAGIDIH BHAWANIPUR CHAS
Email IDanil256773@gmail.com
Mobile No8580334119
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 473.00
2 Plot area as per Document by Applicant 473.00
3 Physical area measured at site 473.00
4 Area as per Site Visit (Site Visit Report) 473.00
5Area as per Drawing 473.33

Area of Plot Considered : 473.00

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 473.00
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 473.00
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 410.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 62.45
62.45
Balance Plot Area 410.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 283.80
Proposed Coverage Area ( 42.99 % ) 203.34
Total Prop. Coverage Area ( 42.99 % ) 203.34
Balance coverage area ( 17.01 % ) 80.46
FAR CHECK
Perm. FAR Area ( 2.50 ) 1182.50
Total Perm. FAR area 1182.50
Residential FAR 181.41
Commercial FAR 560.97
Proposed FAR Area 753.54
Total Proposed FAR Area 753.54
Consumed FAR (Factor) 1.59
Balance FAR Area 428.96
BUA CHECK
Total Proposed BuiltUp Area 1080.21


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 15 60.00
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 473 473.33

[-] Road width Details Checks
No Rule Status
1 For Existing Road Width, value as per site visit and value as per drawing should be same. Failed
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 47.30 62.45 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 62.45 0.00 0.00 - 4.76 - 72.72 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 11 OK
   
   
   
    [-] Building Miscellanies Checks

Building Sr. No. Remarks Required/Permissible Proposed Status
A (RAMAYAN RAM) 1 RAMP should not intersect/outside the Plot at Basement Floor Plan in A (RAMAYAN RAM) Building. 0 0 Failed
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RAMAYAN RAM) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RAMAYAN RAM) 96.50 11.50 11.50 11.50 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RAMAYAN RAM) Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.40 OK
Basement Floor 2.40 - 2.85 2.40 - 2.75 2.10 - 2.40 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RAMAYAN RAM) Terrace Floor - - 1.00 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (RAMAYAN RAM) Basement Floor - 1.55 - 266.85 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (RAMAYAN RAM) - 266.85
Total - 266.85 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (RAMAYAN RAM)   60.0 M ROAD 2.00 3.15 2.00 3.67 0.90 0.90 0.90 1.88 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RAMAYAN RAM) - 4 - 5 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (RAMAYAN RAM) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
283.80 203.34 OK
60% 42.99%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RAMAYAN RAM) - 203.34
  Total Prop. Coverage Area - 203.34
  Total Coverage Area 283.80 203.34

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Lift Lobby Accessory Use Parking Resi. Commercial Stair
A (RAMAYAN RAM) 1 1080.21 17.25 40.26 17.54 251.61 181.41 560.97 11.16 753.55 753.55 05
Grand Total : 1 1080.21 17.25 40.26 17.54 251.61 181.41 560.97 11.16 753.55 753.55 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RAMAYAN RAM)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 266.85 11.16 266.85 11.16
Ground Floor 203.34 203.34 203.34 203.34
First Floor 203.34 178.82 203.34 178.82
Second Floor 203.34 178.82 203.34 178.82
Third Floor 203.34 181.41 203.34 181.41
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1080.21 753.55 1080.21 753.55


[-] UnitBUA Table for Building :A (RAMAYAN RAM)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHOP-1 SHOP 148.87 147.95 2 1
THIRD FLOOR PLAN UNIT NO- 1 FLAT 81.62 81.19 7 2
UNIT NO- 2 FLAT 75.63 75.44 8
TYPICAL - 1& 2 FLOOR PLAN SHOP-1 SHOP 148.87 147.95 2 2
Total: - - 603.86 600.48 21 5


[-] Building :A (RAMAYAN RAM)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Lift Lobby Accessory Use Parking Resi. Commercial Stair
Basement Floor 266.85 4.08 0.00 0.00 251.61 0.00 0.00 11.16 11.16 11.16 00
Ground Floor 203.34 0.00 0.00 0.00 0.00 0.00 203.34 0.00 203.34 203.34 01
First Floor 203.34 4.39 20.13 0.00 0.00 0.00 178.82 0.00 178.82 178.82 01
Second Floor 203.34 4.39 20.13 0.00 0.00 0.00 178.82 0.00 178.82 178.82 01
Third Floor 203.34 4.39 0.00 17.54 0.00 181.41 0.00 0.00 181.41 181.41 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1080.21 17.25 40.26 17.54 251.61 181.41 560.97 11.16 753.55 753.55 05
Total Number of Same Buildings : 1
Total : 1080.21 17.25 40.26 17.54 251.61 181.41 560.97 11.16 753.55 753.55 05
[-] Table 4c-2

  FAR Area
Building FAR Area:753.54
Existing FAR Area :0.00
Perm.
1182.50
Prop.
753.54
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RAMAYAN RAM) 60.0 M ROAD 4.00 6.50 3.00 4.00 0.90 2.00 0.90 2.00 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
A (RAMAYAN RAM) 11.50 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :A (RAMAYAN RAM)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.70 1.90 2.40 OK
GROUND FLOOR PLAN Lift Lobby 1.70 3.00 1.90 6.94 OK
Lift 1.70 1.83 1.90 2.40 OK
THIRD FLOOR PLAN Lift 1.70 1.83 1.90 2.40 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.83 1.90 2.40 OK
TYPICAL - 1& 2 FLOOR PLAN Lift Lobby 1.70 3.00 1.90 6.71 OK
Lift 1.70 1.83 1.90 2.40 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (RAMAYAN RAM) Commercial Shop > 0 50 502.28 1 7 - - - - - - -
> 0 50 502.28 - - - - - - 1 21 -
Residential Residential Bldg/Apartment > 0 1 2.00 1.00 2 - - - - - - -
> 0 1 2.00 - - - - - - 1 2 -
> 0 1 2.00 - - - 1 1 - - - -
Total : - - - - 9 12 - 1 1 - 23 24

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 7 87.50 OK
Two Stack.Car - - 5 62.50 OK
Total Car 9 112.50 12 150.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 24 48.00 OK
Total TwoWheeler 23 46.00 24 48.00 OK
Other Parking - - - 145.61 OK
Total 171.00 404.11 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
PLOT - DRIVEWAY 3.00 - 3.00 OK
A (RAMAYAN RAM) BASEMENT FLOOR PLAN DRIVEWAY 3.60 - 3.78 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RAMAYAN RAM)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK
THIRD FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.200 - 0.250 - 0.000 - 0 - - 2.400 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
3.81 mt. long 1.50 mt. High 3.78 mt. Wide Natural Slope - 3.78 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (RAMAYAN RAM) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 1.01 - - 0.99 - - 1.02 - - 0.00 OK
SUMP TANK - - 1.01 - - 0.99 - - 1.02 - - 0.00 OK
RAIN WATER HARVESTING - - 1.01 - - 0.99 - - 1.02 - - 0.00 OK
ENT.GATE - - 0.69 - - 0.23 - - 3.00 - - 0.00 OK
Entrance Lobby - 12.00 7.64 - - 1.84 - - 4.17 - - 0.00 OK
Entrance Lobby - 12.00 5.39 - - 1.20 - - 4.49 - - 0.00 OK
Entrance Lobby - 12.00 4.51 - - 1.84 - - 2.46 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.01 - - 0.99 - - 1.02 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RAMAYAN RAM) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RAMAYAN RAM)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:THIRD FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 473.00 OK
  Plot Width - 14.78 OK
  Plot Depth - 32.04 OK
  Access Width - 60.00 OK
  Plot Frontage - 15.69 OK
  Coverage Area 283.80 203.34 OK
  FAR Area
Bldg. FAR Area : 753.54
Sanctioned FAR Area :0.00
1182.50 753.54 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 27-33 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.0 mt., Rear 3.0 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(9) No need to check distance from Building Entrance Lobby
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)