-
No Image Found   

Check List Report

Chas Municipal Corporation

Version Number: 1.0.65  
Version Date: 16/10/2020 
Report Generated On: 16-02-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0032/W04/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageChas
Taluka17
Architect Details
Architect NameAMRIT KUMAR MAHATO
License No.CMC/DFTMN/0004/2019
Architect AddressVILLAGE+P.O.+PS.- PINDRAJORA DIST- BOKARO
Architect EmailIDamritcmc2019@gmail.com
Architect Mobile No9955117070
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1420
NorthCTS No. - MANJEET KAUR
SouthCTS No. - RAJESH JHA
EastCTS No. - UMRAWATI DEVI
WestRoad Width - ROAD
Owner's Details
Name1.ANNPURNA SHARMA 2.ANJANI KUMAR SHAHI
AddressCHIAR CHAS BOKARO
Email IDakmahto70@gmail.com
Mobile No7717799432
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 185.81
2 Plot area as per Document by Applicant 185.81
3 Physical area measured at site 185.81
4 Area as per Site Visit (Site Visit Report) 185.81
5Area as per Drawing 185.78

Area of Plot Considered : 185.78

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 185.78
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 185.78
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 160.05
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.73
25.73
Balance Plot Area 160.05

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 130.05
Proposed Coverage Area ( 44.02 % ) 81.79
Total Prop. Coverage Area ( 44.02 % ) 81.79
Balance coverage area ( 25.98 % ) 48.26
FAR CHECK
Perm. FAR Area ( 2.000 ) 371.56
Total Perm. FAR area 371.56
Residential FAR 166.09
Proposed FAR Area 166.09
Total Proposed FAR Area 166.09
Consumed FAR (Factor) 0.89
Balance FAR Area 205.47
BUA CHECK
Total Proposed BuiltUp Area 166.09


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 185.81 185.78
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 185.78 OK
Plot Width Mt. - - 12.18 OK
Plot Depth Mt. - - 15.25 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 12.18 OK
Coverage Area Sq.Mt. - 130.05 81.79 OK
FAR Area Sq.Mt. - 371.56 166.09 OK
Consumed FAR Sq.Mt. - 2.00 0.89 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 9.29 25.73 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 11.74 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.00 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 13.99 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.26 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 8 OK
A-1 (PRO BUILDING) Front Margin... 6.10 M ROAD Mt. 2.50 - 2.59 OK
Rear Margin Mt. 1.50 - 1.53 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. 0.90 - 2.75 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (PRO BUILDING) Height Mt. 11.74 6.10 OK
A (PRO BUILDING) First Floor - Height Mt. 2.75 - 3.05 OK
First Floor - Clear Height Mt. 2.75 - 2.95 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 3.05 OK
Ground Floor - Clear Height Mt. 2.75 - 2.95 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.75 OK
Plinth - Height Mt. 0.45 - 0.46 OK
Plinth - Clear Height Mt. - - 0.46 OK
Plinth - Beam Clear Height Mt. - - 0.46 OK
A (PRO BUILDING) Terrace Floor - Height Mt. - - 1.06 OK
Terrace Floor - Clear Height Mt. - - 1.06 OK
Terrace Floor - Beam Clear Height Mt. - - 1.06 OK
A (PRO BUILDING) No. of Floors No. G + 4 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN Internal Staircase - Flight Width Mt. - 1.000 OK
Internal Staircase - Tread Width Mt. - 0.250 OK
Internal Staircase - Riser Height Mt. - 0.152 OK
Internal Staircase - Riser No. On Flight No. 14 14 OK
Internal Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Internal Staircase - Flight Width Mt. - 1.000 OK
Internal Staircase - Tread Width Mt. - 0.250 OK
Internal Staircase - Riser Height Mt. - 0.152 OK
Internal Staircase - Riser No. On Flight No. 14 14 OK
Internal Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase - Flight Width Mt. - 1.000 OK
Staircase - Tread Width Mt. - 0.250 OK
Staircase - Riser Height Mt. - - OK
Staircase - Riser No. On Flight No. - - OK
Staircase - Cabin Ht. Mt. 2.100 - 2.439 OK
SUMP TANK Area Sq.Mt. - - 0.69 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 0.94 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.69 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 0.94 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.31 OK
Width Mt. - - 0.42 OK
Depth Mt. - - 3.12 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.69 OK
Width Mt. - - 0.74 OK
Depth Mt. - - 0.94 OK
Height Mt. - - - OK
A (PRO BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In New Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For new area, on Road width 6.1-7.5 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For new area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 16}
StairCase (1) No Rule Defined
(2) ; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)