General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0121/W02/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageChas
Taluka17
Architect Details
Architect NameDINABANDHU RAJAK
License No.CMC/ENG/0001/2020
Architect AddressVILLAGE-CHIRDA P.O.- GAMARIYA P.S.- CHANDANKIYARI DIST- BOKARO JHARKHAND
Architect EmailIDdinbandhu16690@gmail.com
Architect Mobile No8340603143
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No991
NorthCTS No. - RISHABH PRATAP
SouthCTS No. - SRI MUKESH
EastPlot No. - PART OF PLOT
WestRoad Width - 6.10 MTR WIDE ROAD
Owner's Details
NameRAMESH
AddressSECTOR-3/E QTR NO.- 115 B.S. CITY
Email IDramesh27@licindia.com
Mobile No9431512003
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 344.10
2 Plot area as per Document by Applicant 344.10
3 Physical area measured at site 304.00
4 Area as per Site Visit (Site Visit Report) 304.00
5Area as per Drawing 303.63

Area of Plot Considered : 303.63

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 303.63
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 303.63
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 281.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 22.55
22.55
Balance Plot Area 281.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 182.18
Proposed Coverage Area ( 59.84 % ) 181.69
Total Prop. Coverage Area ( 59.84 % ) 181.69
Balance coverage area ( 0.16 % ) 0.49
FAR CHECK
Perm. FAR Area ( 2.500 ) 759.08
Total Perm. FAR area 759.08
Residential FAR 599.25
Proposed FAR Area 599.25
Total Proposed FAR Area 599.25
Consumed FAR (Factor) 1.97
Balance FAR Area 159.83
BUA CHECK
Total Proposed BuiltUp Area 599.25


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 304 303.63
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 303.63 OK
Plot Width Mt. - - 13.68 OK
Plot Depth Mt. - - 22.20 OK
Access Width Mt. - - 6.10 OK
Plot Frontage Mt. - - 13.56 OK
Coverage Area Sq.Mt. - 182.18 181.69 OK
FAR Area Sq.Mt. - 759.08 599.25 OK
Consumed FAR Sq.Mt. - 2.50 1.97 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 15.18 22.55 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 22.55 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.10 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 4 OK
A-1 (RAMESH) Front Margin... 6.10M ROAD Mt. 3.00 - 4.80 OK
Rear Margin Mt. 1.80 - 1.82 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. 0.90 - 0.95 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (RAMESH) Height Mt. 13.95 9.45 OK
A (RAMESH) Second Floor - Height Mt. 2.75 - 3.15 OK
Second Floor - Clear Height Mt. 2.75 - 3.05 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.91 OK
First Floor - Height Mt. 2.75 - 3.15 OK
First Floor - Clear Height Mt. 2.75 - 3.05 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.91 OK
Ground Floor - Height Mt. 2.75 - 3.15 OK
Ground Floor - Clear Height Mt. 2.75 - 3.05 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.91 OK
Plinth - Height Mt. 0.45 - 0.60 OK
Plinth - Clear Height Mt. - - 0.60 OK
Plinth - Beam Clear Height Mt. - - 0.60 OK
A (RAMESH) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 0.90 OK
Terrace Floor - Beam Clear Height Mt. - - 0.90 OK
A (RAMESH) No. of Floors No. G + 4 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.190 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.131 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.190 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.131 OK
STAIRCASE - Riser No. On Flight No. - 12 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCABIN - Flight Width Mt. - 1.190 OK
STAIRCABIN - Tread Width Mt. - 0.250 OK
STAIRCABIN - Riser Height Mt. - - OK
STAIRCABIN - Riser No. On Flight No. - - OK
STAIRCABIN - Cabin Ht. Mt. - - 2.400 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 5.87 OK
Width Mt. - - 2.11 OK
Depth Mt. - - 2.78 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.19 OK
Width Mt. - - 0.31 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 4.94 OK
Width Mt. - - 0.76 OK
Depth Mt. - - 6.51 OK
Height Mt. - - - OK
A (RAMESH) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bath2.38x1.20 Area for Bathroom shall be Mini. 1.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Bed Room3.65x2.95 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.73x3.75 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.34x3.65 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.36x4.84 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dining2.21x5.26 No Rule Defined
Dining4.26x8.81 No Rule Defined
Drawing Room4.36x3.65 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Drawing Room4.36x6.24 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dress Room2.38x1.20 No Rule Defined
Foyer4.36x2.32 No Rule Defined
Kitchen3.45x3.05 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen4.34x3.05 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Puja2.10x1.50 No Rule Defined
Servant Room2.38x2.40 No Rule Defined
Sitout1.00x3.28 No Rule Defined
Sitout2.74x11.76 No Rule Defined
Toilet2.38x1.20 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.38x2.05 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.38x2.40 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Wc1.51x1.00 No Rule Defined