Check List Report

Chas Municipal Corporation

Version Number: 1.0.70  
Version Date: 16/10/2020 
Report Generated On: 31-05-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictBOKARO
AuthorityCHAS MUNICIPAL CORPORATION
Inward_NoCMC/BP/0054/W06/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBhawanipur
Taluka17
Architect Details
Architect NamePUJA KUMARI
License No.CMC/ENG/0005/2023
Architect AddressVILL-JODHADIH MORE CHAS CHANDANKIYARI ROAD P.O-CHAS
Architect EmailIDpujakumaricivil1997@gmail.com
Architect Mobile No9955585254
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No300
NorthPlot No. - RAMRUDRA HIGH SCHOOL
SouthPlot No. - VENDOR NIJJ
EastRoad Width - NH 32
WestRoad Width - GALI RASTA
Owner's Details
NameMEERA RANI DEVI AND AMIT KUMAR DUBEY
AddressBIJULIA, BOKARO
Email IDayanshraj11018@gmail.com
Mobile No7739155252
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 163.93
2 Plot area as per Document by Applicant 163.93
3 Physical area measured at site 163.93
4 Area as per Site Visit (Site Visit Report) 163.93
5Area as per Drawing 163.92

Area of Plot Considered : 163.92

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 163.92
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 163.92
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 141.22
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 22.70
22.70
Balance Plot Area 141.22

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 98.35
Proposed Coverage Area ( 56.42 % ) 92.48
Total Prop. Coverage Area ( 56.42 % ) 92.48
Balance coverage area ( 3.58 % ) 5.87
FAR CHECK
Perm. FAR Area ( 2.500 ) 409.80
Total Perm. FAR area 409.80
Residential FAR 173.78
Commercial FAR 86.89
Proposed FAR Area 281.90
Total Proposed FAR Area 281.90
Consumed FAR (Factor) 1.72
Balance FAR Area 127.90
BUA CHECK
Total Proposed BuiltUp Area 462.40


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 30 30.00
Proposed Road Width as per Master Plan 30 -
Road Widening Width 0 -
Plot size (as per measurement) 163.93 163.92
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 163.92 OK
Plot Width Mt. - - 10.60 OK
Plot Depth Mt. - - 15.47 OK
Access Width Mt. - - 30.00 OK
Plot Frontage Mt. - - 11.18 OK
Coverage Area Sq.Mt. - 98.35 92.48 OK
FAR Area Sq.Mt. - 409.80 281.90 OK
Consumed FAR Sq.Mt. - 2.50 1.72 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 16.39 22.70 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 22.70 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.51 OK
Tree Cover (Plantation) - Angle Degree - 66.93 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 4 OK
Car In Area Sq.Mt. - - 50.00 OK
Total Car In Area Sq.Mt. 50.00 - 50.00 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
Total Visitor Parking In Area Sq.Mt. 12.50 - 12.50 OK
TwoWheeler In Area Sq.Mt. - - 12.00 OK
Total TwoWheeler In Area Sq.Mt. 12.00 - 12.00 OK
Other Parking In Area Sq.Mt. - - 78.32 OK
DriveWay A (MIXED BUILDING) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.65 OK
A-1 (MIXED BUILDING) Front Margin... 30.0 M ROAD Mt. 3.00 - 3.00 OK
Rear Margin Mt. 1.80 - 1.80 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. 0.90 - 0.90 OK
A-1 (MIXED BUILDING) Basement Front Margin... 30.0 M ROAD Mt. 2.00 - 3.00 OK
Basement Rear Margin Mt. 1.80 - 1.80 OK
Basement Side1 Margin Mt. 0.90 - 0.90 OK
Basement Side2 Margin Mt. 0.90 - 0.90 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MIXED BUILDING) Height Mt. 48.00 12.00 OK
A (MIXED BUILDING) Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.77 OK
Basement Floor - Height Mt. 2.40 - 2.80 OK
Basement Floor - Clear Height Mt. 2.40 - 2.70 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.57 OK
A (MIXED BUILDING) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (MIXED BUILDING) Basement Floor - Height of Basement Floor above GL Mt. - - 1.20 OK
Basement Floor - Area Sq.Mt. - 92.48 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
A (MIXED BUILDING) Area Sq.Mt. - 92.48 OK
Status - OK
Total Area Sq.Mt. - 92.48 OK
A (MIXED BUILDING) No. of Basement Floor No. 1 1 OK
A (MIXED BUILDING) No. of Floors No. - 4 OK
No. of Tenements No. - 3 OK
A (MIXED BUILDING) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (MIXED BUILDING) BASEMENT FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
BASEMENT FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 2& 3 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2& 3 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2& 3 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.136 OK
STAIRCASE - Riser No. On Flight No. - 11 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
SUMP TANK Area Sq.Mt. - - 0.38 OK
Width Mt. - - 0.59 OK
Depth Mt. - - 0.65 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.38 OK
Width Mt. - - 0.59 OK
Depth Mt. - - 0.65 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.70 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 3.10 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 2.36 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 2.36 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 2.36 OK
Width Mt. - - 1.00 OK
Depth Mt. - - 2.36 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.38 OK
Width Mt. - - 0.59 OK
Depth Mt. - - 0.65 OK
Height Mt. - - - OK
A (MIXED BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
PLOT 3.81 mt. long 1.50 mt. High 3.78 mt. Wide Natural Slope - Width Mt. - 1.24 OK
3.81 mt. long 1.50 mt. High 3.78 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
3.81 mt. long 1.50 mt. High 3.78 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (MIXED BUILDING) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For Chas Municipal Corporation, Max. 2.5 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height -,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.14x4.25 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.38x6.26 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Dining/kitchen4.50x6.44 Area for Kitchen-dinning shall be Mini. 7.5 sq.mt. having side mini. 2.1 mt. {Rule No. 42.3.2}
Toilet1.50x2.06 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}