No Image Found   

Check List Report

Jugsalai Municipality

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 13-04-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJUGSALAI MUNICIPALITY
Inward_NoJMP/BP/0004/W04/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJugsalai
Taluka16
Architect Details
Architect NameL K Suman
License No.JMP/ENG/0007/2017
Architect Address2nd Floor, Basant Taklies Complex, sakchi, Jamshedpur.
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No1410, 1412
NorthPlot No. - Kuldeep Hotel
SouthPlot No. - other plot
EastRoad Width - 6.2
WestPlot No. - other plot
Owner's Details
NameSRI VARINDER SINGH AND SMT. JATINDER KAUR
AddressSTATION ROAD JUGSALAI, JAMSHEDPUR
Email IDvarindersingh1290@gmail.com
Mobile No7903042439
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 325.92
2 Plot area as per Document by Applicant 325.81
3 Physical area measured at site 325.81
4 Area as per Site Visit (Site Visit Report) 325.81
5Area as per Drawing 325.66

Area of Plot Considered : 325.66

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPROPOSED B+G+3
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 325.66
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 325.66
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 275.91
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 49.75
49.75
Balance Plot Area 275.91

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 195.40
Proposed Coverage Area ( 52.62 % ) 171.37
Total Prop. Coverage Area ( 52.62 % ) 171.37
Balance coverage area ( 7.38 % ) 24.03
FAR CHECK
Perm. FAR Area ( 2.50 ) 814.15
Total Perm. FAR area 814.15
Residential FAR 644.33
Commercial FAR 137.52
Proposed FAR Area 793.73
Total Proposed FAR Area 793.73
Consumed FAR (Factor) 2.44
Balance FAR Area 20.42
BUA CHECK
Total Proposed BuiltUp Area 1036.30


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.2 6.20
Proposed Road Width as per Master Plan 6.2 -
Road Widening Width 0 -
Plot size (as per measurement) 325.81 325.66
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 325.66 OK
Plot Width Mt. - - 13.37 OK
Plot Depth Mt. - - 24.37 OK
Access Width Mt. 6.10 - 6.20 OK
Plot Frontage Mt. - - 11.55 OK
Coverage Area Sq.Mt. - 195.40 171.37 OK
FAR Area Sq.Mt. - 814.15 793.73 OK
Consumed FAR Sq.Mt. - 2.50 2.44 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 32.57 49.75 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 15.77 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.40 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Cover (Plantation) - Minimum Area Sq.Mt. - 33.98 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.72 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 17 OK
Car In Area Sq.Mt. - - 50.00 OK
Four Stack.Car In Area Sq.Mt. - - 150.00 OK
Total Car In Area Sq.Mt. 150.00 - 200.00 OK
Total Visitor Parking In Area Sq.Mt. 25.00 - 27.00 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 27.00 OK
TwoWheeler In Area Sq.Mt. - - 36.00 OK
Four Stack. TwoWheeler In Area Sq.Mt. - - 48.00 OK
Total TwoWheeler In Area Sq.Mt. 24.00 - 84.00 OK
Other Parking In Area Sq.Mt. - - 99.18 OK
DriveWay PROPOSED B+G+3 - - - DRIVEWAY - Width No. 3.00 - 3.67 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.67 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.00 - 3.20 OK
A-1 (SRI VARINDER SINGH AND SMT JATINDER KAUR) Front Margin... 6.2 M WIDE ROAD Access Road Mt. 3.50 - 4.79 OK
Rear Margin Mt. 2.50 - 2.51 OK
Side1 Margin Mt. 1.00 - 1.36 OK
Side2 Margin Mt. 1.00 - 1.45 OK
A-1 (SRI VARINDER SINGH AND SMT JATINDER KAUR) Basement Front Margin... 6.2 M WIDE ROAD Access Road Mt. 2.00 - 3.93 OK
Basement Rear Margin Mt. 2.00 - 2.00 OK
Basement Side1 Margin Mt. 1.00 - 1.39 OK
Basement Side2 Margin Mt. 1.00 - 1.44 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Height Mt. 14.09 14.00 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Fourth Floor - Height Mt. 2.75 - 2.80 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.78 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.41 OK
Third Floor - Height Mt. 2.75 - 2.80 OK
Third Floor - Clear Height Mt. 2.75 - 2.78 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.41 OK
Second Floor - Height Mt. 2.75 - 2.80 OK
Second Floor - Clear Height Mt. 2.75 - 2.78 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.41 OK
First Floor - Height Mt. 2.75 - 2.80 OK
First Floor - Clear Height Mt. 2.75 - 2.78 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.41 OK
Ground Floor - Height Mt. 2.75 - 2.80 OK
Ground Floor - Clear Height Mt. 2.75 - 2.78 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.41 OK
Basement Floor - Height Mt. 2.40 - 2.80 OK
Basement Floor - Clear Height Mt. 2.40 - 2.78 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.41 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Terrace Floor - Height Mt. - - 0.91 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Basement Floor - Height Below GL Mt. - 2.80 OK
Basement Floor - Area Sq.Mt. - 187.06 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Area Sq.Mt. - 187.06 OK
Status - OK
Total Area Sq.Mt. - 187.06 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) No. of Basement Floor No. 1 1 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) No. of Floors No. G + 4 5 OK
No. of Tenements No. - 21 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.085 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.525 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.477 OK
STAIRCASE - Tread Width Mt. 0.250 0.307 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.085 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.140 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3 & 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.085 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.140 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.98 OK
Width Mt. - - 0.97 OK
Depth Mt. - - 1.00 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.01 OK
Width Mt. - - 1.36 OK
Depth Mt. - - 1.48 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.14 OK
Width Mt. - - 0.19 OK
Depth Mt. - - 0.74 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 7.56 OK
Width Mt. - - 1.96 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.56 OK
Width Mt. - - 1.96 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.56 OK
Width Mt. - - 1.96 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 7.56 OK
Width Mt. - - 1.96 OK
Depth Mt. - - 3.87 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 3.62 OK
Width Mt. - - 1.85 OK
Depth Mt. - - 1.96 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 5.16 OK
Width Mt. - - 1.96 OK
Depth Mt. - - 2.82 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 2.01 OK
Width Mt. - - 1.36 OK
Depth Mt. - - 1.48 OK
Height Mt. - - - OK
Area Sq.Mt. - - 3.08 OK
Width Mt. - - 1.28 OK
Depth Mt. - - 2.42 OK
Height Mt. - - - OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PROPOSED B+G+3 1.76 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Width Mt. - 1.77 OK
1.76 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
1.76 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Slope Ratio - - - OK
3.53 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Width Mt. - 3.53 OK
3.53 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
3.53 mt. long 1.50 mt. High 3.66 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - TERRACE FLOOR PLAN - No. No. - 1 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - GROUND FLOOR PLAN - No. No. - 1 OK
A (SRI VARINDER SINGH AND SMT JATINDER KAUR) - TYPICAL - 1, 2, 3 & 4 FLOOR PLAN - No. No. - 4 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.5 mt., Rear 2.5mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well shall not be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) -
(2) For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)