No Image Found   

Detail Scrutiny Report

Jugsalai Municipality

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 17-12-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJUGSALAI MUNICIPALITY
Inward_NoJMP/BP/0007/W05/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJugsalai
Taluka16
Architect Details
Architect NameAnil kumar marandi
License No.JMP/ARC/0008/2017
Architect AddressE/4, MAA DURGA APPARTMENT, KARANDIH CHUAK, JAMSHEDPUR
Architect EmailIDanil.marandi@gmail.com
Architect Mobile No9031583891
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No70
NorthPlot No. - KISHORE SHARMA
SouthPlot No. - MANGOTIA CONSTRUCTION
EastPlot No. - ICE FACTORy
WestRoad Width - 6.70 MTR WIDE MAIN ROAD
Owner's Details
NameBAIDYANATH SHARMA
AddressBORA PATI NEW BAZAR JUGSALAI JAMSHEDPUR
Email IDanil.marandi@gmail.com
Mobile No8603407981
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 250.90
2 Plot area as per Document by Applicant 250.90
3 Physical area measured at site 250.90
4 Area as per Site Visit (Site Visit Report) 250.90
5Area as per Drawing 248.96

Area of Plot Considered : 248.96

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 248.96
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 248.96
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 222.98
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.98
25.98
Balance Plot Area 222.98

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 149.38
Proposed Coverage Area ( 52.73 % ) 131.28
Total Prop. Coverage Area ( 52.73 % ) 131.28
Balance coverage area ( 7.27 % ) 18.10
FAR CHECK
Perm. FAR Area ( 2.500 ) 622.40
Total Perm. FAR area 622.40
Residential FAR 379.58
Proposed FAR Area 379.58
Total Proposed FAR Area 379.58
Consumed FAR (Factor) 1.52
Balance FAR Area 242.82
BUA CHECK
Total Proposed BuiltUp Area 398.59


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 6.7 6.70
Proposed Road Width as per Master Plan 6.7 -
Road Widening Width 0.001 -
Plot size (as per measurement) 250.9 248.96
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 12.45 25.98 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 25.98 0.00 0.00 - 1.76 - 88.03 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 16 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (BAIDYANATH SHARMA) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (BAIDYANATH SHARMA) 13.52 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BAIDYANATH SHARMA) Second Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
First Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Ground Floor 2.75 - 3.00 2.75 - 2.90 2.40 - 2.75 OK
Plinth 0.45 - 0.46 - - 0.46 - - 0.46 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (BAIDYANATH SHARMA) Terrace Floor - - 1.03 - - 1.03 - - 1.03 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (BAIDYANATH SHARMA) G + 4 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
149.38 131.28 OK
60% 52.73%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (BAIDYANATH SHARMA) - 131.28
  Total Prop. Coverage Area - 131.28
  Total Coverage Area 149.38 131.28

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Accessory Use Resi.
A (BAIDYANATH SHARMA) 1 406.33 7.74 398.59 19.00 379.59 379.59 379.59 01
Grand Total : 1 406.33 7.74 398.59 19.00 379.59 379.59 379.59 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (BAIDYANATH SHARMA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 131.28 126.53 131.28 126.53
First Floor 131.28 126.53 131.28 126.53
Second Floor 131.28 126.53 131.28 126.53
Terrace Floor 4.75 0.00 4.75 0.00
Total : 398.59 379.59 398.59 379.59


[-] UnitBUA Table for Building :A (BAIDYANATH SHARMA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 312.84 312.57 7 1
FIRST FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
Total: - - 312.84 312.57 21 1


[-] Building :A (BAIDYANATH SHARMA)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Accessory Use Resi.
Ground Floor 133.86 2.58 131.28 4.75 126.53 126.53 126.53 01
First Floor 133.86 2.58 131.28 4.75 126.53 126.53 126.53 00
Second Floor 133.86 2.58 131.28 4.75 126.53 126.53 126.53 00
Terrace Floor 4.75 0.00 4.75 4.75 0.00 0.00 0.00 00
Total : 406.33 7.74 398.59 19.00 379.59 379.59 379.59 01
Total Number of Same Buildings : 1
Total : 406.33 7.74 398.59 19.00 379.59 379.59 379.59 01
[-] Table 4c-2

  FAR Area
Building FAR Area:379.58
Existing FAR Area :0.00
Perm.
622.40
Prop.
379.58
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (BAIDYANATH SHARMA) 6.70 MTR WIDE ROAD Access Road 3.00 3.47 1.80 1.88 0.90 1.04 0.90 0.95 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (BAIDYANATH SHARMA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (BAIDYANATH SHARMA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.097 - 9 - - 0.000 OK
FIRST FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.097 - 9 - - 0.000 OK
SECOND FLOOR PLAN Staircase -3FL 0.900 0.991 0.250 0.254 0.200 0.097 - 9 - - 0.000 OK
TERRACE FLOOR PLAN Staircase -3FL - 0.991 - 0.254 - 0.000 - 0 - - 2.534 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.94 - - 0.81 - - 1.15 - - 0.00 OK
RAIN WATER HARVESTING - - 2.02 - - 1.41 - - 1.44 - - 0.00 OK
ENT.GATE - - 0.90 - - 0.23 - - 3.92 - - 0.00 OK
Entrance Lobby - 12.00 4.75 - - 1.57 - - 3.02 - - 0.00 OK
Entrance Lobby - 12.00 4.75 - - 1.57 - - 3.02 - - 0.00 OK
Entrance Lobby - 12.00 4.75 - - 1.57 - - 3.02 - - 0.00 OK
Entrance Lobby - 12.00 4.75 - - 1.57 - - 3.02 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.34 - - 1.15 - - 1.16 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (BAIDYANATH SHARMA) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (BAIDYANATH SHARMA)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 248.96 OK
  Plot Width - 11.06 OK
  Plot Depth - 22.50 OK
  Access Width - 6.70 OK
  Plot Frontage - 11.90 OK
  Coverage Area 149.38 131.28 OK
  FAR Area
Bldg. FAR Area : 379.58
Sanctioned FAR Area :0.00
622.40 379.58 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)