Detail Scrutiny Report

Jugsalai Municipality

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 11-03-2024 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJUGSALAI MUNICIPALITY
Inward_NoJMP/BP/0007/W04/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJugsalai
Taluka16
Architect Details
Architect NameNIKHIL SHUKLA
License No.JMP/ARC/0001/2018
Architect AddressHOUSE NO- 125, CHANAKYAPURI COLONY, OLD PURULIA ROAD, NEAR JESU MANGO, JAMSHEDPUR
Architect EmailID nikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No534 a,b,c,d&e (N),535
North -
SouthRoad Width - 7.5
East -
West -
Owner's Details
NameMRS INDERJEET KAUR
AddressR/O WARD N0-6 G0URI SHANKAR ROAD JUGSALAI JSR
Email IDgvndsingh60@gmail.com
Mobile No7717795307
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 510.89
2 Plot area as per Document by Applicant 510.89
3 Physical area measured at site 510.89
4 Area as per Site Visit (Site Visit Report) 510.89
5Area as per Drawing 510.89

Area of Plot Considered : 510.89

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 510.89
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 510.89
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 424.49
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 86.40
86.40
Balance Plot Area 424.49

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 255.45
Proposed Coverage Area ( 39.03 % ) 199.39
Total Prop. Coverage Area ( 39.03 % ) 199.39
Balance coverage area ( 10.97 % ) 56.06
FAR CHECK
Perm. FAR Area ( 2.500 ) 1277.23
Total Perm. FAR area 1277.23
Commercial FAR 871.80
Proposed FAR Area 884.07
Total Proposed FAR Area 884.07
Consumed FAR (Factor) 1.73
Balance FAR Area 393.16
BUA CHECK
Total Proposed BuiltUp Area 1258.16


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 7.5 7.50
Proposed Road Width as per Master Plan 7.5 -
Road Widening Width 0.001 -
Plot size (as per measurement) 510.89 510.89
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 51.09 86.40 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 86.40 0.00 0.00 - 3.97 - 84.72 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
COMMERCIAL (BUILDING) Commercial Commercial Bldg Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
COMMERCIAL (BUILDING) 18.29 14.27 14.27 14.27 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
COMMERCIAL (BUILDING) Fourth Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Basement Floor 2.40 - 2.85 2.40 - 2.75 2.10 - 2.47 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
COMMERCIAL (BUILDING) Terrace Floor - - 1.07 - - 1.07 - - 1.07 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
COMMERCIAL (BUILDING) Basement Floor 0.90 1.50 1.22 - 209.69 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
COMMERCIAL (BUILDING) - 209.69
Total - 209.69 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  COMMERCIAL-1 (BUILDING)   7.5 M WIDE MAINROAD Access Road 2.00 7.05 2.00 4.53 2.00 2.74 2.00 2.27 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
COMMERCIAL (BUILDING) G + 5 5 - 5 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
COMMERCIAL (BUILDING) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
255.45 199.39 OK
50% 39.03%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  COMMERCIAL-1 (BUILDING) - 199.39
  Total Prop. Coverage Area - 199.39
  Total Coverage Area 255.45 199.39

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Void Accessory Use Parking Commercial Stair
COMMERCIAL (BUILDING) 1 1258.16 59.91 32.60 8.41 90.63 182.54 871.80 12.27 884.07 884.07 05
Grand Total : 1 1258.16 59.91 32.60 8.41 90.63 182.54 871.80 12.27 884.07 884.07 05


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
COMMERCIAL (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 209.69 12.27 209.69 12.27
Ground Floor 209.70 187.83 209.70 187.83
First Floor 209.70 189.39 209.70 189.39
Second Floor 209.69 164.86 209.69 164.86
Third Floor 209.69 164.86 209.69 164.86
Fourth Floor 209.69 164.86 209.69 164.86
Terrace Floor 0.00 0.00 0.00 0.00
Total : 1258.16 884.07 1258.16 884.07


[-] UnitBUA Table for Building :COMMERCIAL (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN HOTEL SHOP 162.22 161.45 4 1
FIRST FLOOR PLAN HOTEL SHOP 171.24 170.48 5 1
TYPICAL - 2, 3& 4 FLOOR PLAN HOTEL ROOM OTHER 146.08 144.83 14 3
Total: - - 771.70 766.42 51 5


[-] Building :COMMERCIAL (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
StairCase Lift Void Accessory Use Parking Commercial Stair
Basement Floor 209.69 8.36 6.52 0.00 0.00 182.54 0.00 12.27 12.27 12.27 00
Ground Floor 209.70 10.31 0.00 8.41 3.15 0.00 187.83 0.00 187.83 187.83 01
First Floor 209.70 10.31 6.52 0.00 3.48 0.00 189.39 0.00 189.39 189.39 01
Second Floor 209.69 10.31 6.52 0.00 28.00 0.00 164.86 0.00 164.86 164.86 01
Third Floor 209.69 10.31 6.52 0.00 28.00 0.00 164.86 0.00 164.86 164.86 01
Fourth Floor 209.69 10.31 6.52 0.00 28.00 0.00 164.86 0.00 164.86 164.86 01
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1258.16 59.91 32.60 8.41 90.63 182.54 871.80 12.27 884.07 884.07 05
Total Number of Same Buildings : 1
Total : 1258.16 59.91 32.60 8.41 90.63 182.54 871.80 12.27 884.07 884.07 05
[-] Table 4c-2

  FAR Area
Building FAR Area:884.07
Existing FAR Area :0.00
Perm.
1277.23
Prop.
884.07
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
COMMERCIAL-1 (BUILDING) 7.5 M WIDE MAINROAD Access Road 7.00 7.04 4.50 4.53 2.50 2.74 2.50 2.27 Failed






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
COMMERCIAL (BUILDING) 14.27 2 2 - 0 12 12 OK

[-] Lift Check Table

[-] For Building :COMMERCIAL (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
Lift 1.70 1.71 1.90 1.91 OK
GROUND FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
Lift 1.70 1.71 1.90 1.91 OK
FIRST FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
Lift 1.70 1.71 1.90 1.91 OK
TYPICAL - 2, 3& 4 FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
Lift 1.70 1.71 1.90 1.91 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.71 1.90 1.91 OK
Lift Machine Room 1.70 1.71 1.90 1.91 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
COMMERCIAL (BUILDING) Commercial Commercial Bldg > 0 200 803.93 1 3 - - - -
> 0 200 803.93 - - - 1 9 -
Total : - - - - 3 4 - 9 13

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 4 50.00 OK
Total Car 3 37.50 4 50.00 OK
TwoWheeler - - 13 26.00 OK
Total TwoWheeler 9 18.00 13 26.00 OK
Other Parking - - - 114.54 OK
Total 55.50 216.54 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

[-] Driveway Parking Checks (Table 7d)
Building/Plot Name Floor Name Driveway Name Width Status
Reqd Perm Prop
COMMERCIAL (BUILDING) BASEMENT FLOOR PLAN DRIVEWAY 3.60 - 5.22 OK
DRIVEWAY - - 3.66 OK

   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :COMMERCIAL (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN Fire Escape Staircase 0.900 1.065 0.250 0.267 0.200 0.000 16 0 - - 0.000 OK
STAIRCASE 0.900 1.069 0.250 0.305 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN Fire Escape Staircase 0.900 1.065 0.250 0.267 0.200 0.143 16 10 - - 0.000 OK
STAIRCASE 0.900 1.069 0.250 0.305 0.200 0.143 - 10 - - 0.000 OK
FIRST FLOOR PLAN Fire Escape Staircase 0.900 1.065 0.250 0.267 0.200 0.143 16 10 - - 0.000 OK
STAIRCASE 0.900 1.069 0.250 0.305 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 2, 3& 4 FLOOR PLAN STAIRCASE 0.900 1.069 0.250 0.305 0.200 0.143 - 10 - - 0.000 OK
Fire Escape Staircase 0.900 1.065 0.250 0.267 0.200 0.143 16 10 - - 0.000 OK
TERRACE FLOOR PLAN Fire Escape Staircase - 1.065 - 0.267 - 0.000 16 0 - - 2.591 OK
STAIRCASE - 1.069 - 0.305 - 0.000 - 0 - - 2.591 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
12.00 mt. long 1.63 mt. High 3.66 mt. Wide Natural Slope - 3.66 - 1.63 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
COMMERCIAL (BUILDING) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 2.65 - - 1.21 - - 2.19 - - 0.00 OK
RAIN WATER HARVESTING - - 0.96 - - 1.11 - - 1.11 - - 0.00 OK
ENT.GATE - - 0.40 - - 0.17 - - 2.40 - - 0.00 OK
Entrance Lobby - 12.00 3.15 - - 1.47 - - 2.14 - - 0.00 OK
Entrance Lobby - 12.00 3.48 - - 1.47 - - 2.37 - - 0.00 OK
Entrance Lobby - 12.00 8.84 - - 1.22 - - 7.24 - - 0.00 OK
Entrance Lobby - 12.00 11.25 - - 1.52 - - 7.39 - - 0.00 OK
Entrance Lobby - 12.00 2.50 - - 1.22 - - 2.05 - - 0.00 OK
Entrance Lobby - 12.00 5.42 - - 1.21 - - 4.50 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.99 - - 0.92 - - 1.07 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
COMMERCIAL (BUILDING) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:COMMERCIAL (BUILDING)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 2, 3& 4 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 510.89 OK
  Plot Width - 15.19 OK
  Plot Depth - 33.63 OK
  Access Width 6.10 7.50 OK
  Plot Frontage - 11.49 OK
  Coverage Area 255.45 199.39 OK
  FAR Area
Bldg. FAR Area : 884.07
Sanctioned FAR Area :0.00
1277.23 884.07 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JUGSALAI MUNICIPALITY, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JUGSALAI MUNICIPALITY, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 15-21 mt., Margin required in Front shall be 7.0 mt., Rear 4.5 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
(5) No Rule Defined
(6) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(7) No Rule Defined
(8) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)