No Image Found   

Detail Scrutiny Report

Jugsalai Municipality

Version Number: 1.0.68  
Version Date: 16/10/2020 
Report Generated On: 15-12-2023 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJUGSALAI MUNICIPALITY
Inward_NoJMP/BP/0008/W12/2023
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJugsalai
Taluka16
Architect Details
Architect NameNIKHIL SHUKLA
License No.JMP/ARC/0001/2018
Architect AddressHOUSE NO- 125, CHANAKYAPURI COLONY, OLD PURULIA ROAD, NEAR JESU MANGO, JAMSHEDPUR
Architect EmailID nikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1678(O),1322(N)
NorthRoad Width - 6.10
South -
East -
West -
Owner's Details
Name1.NIHAR RANJAN BISWAL, 2.MANAS RANJAN BISWAL
AddressGOUSHALLA NALA ROAD, JUGSALAI, P.O&P.S JUGSALAI JSR
Email IDreet.babli@gmail.com
Mobile No9308954184
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 133.82
2 Plot area as per Document by Applicant 133.82
3 Physical area measured at site 133.82
4 Area as per Site Visit (Site Visit Report) 133.82
5Area as per Drawing 133.70

Area of Plot Considered : 133.70

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 133.70
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 133.70
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 114.72
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 18.98
18.98
Balance Plot Area 114.72

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 80.22
Proposed Coverage Area ( 47.84 % ) 63.96
Total Prop. Coverage Area ( 47.84 % ) 63.96
Balance coverage area ( 12.16 % ) 16.26
FAR CHECK
Perm. FAR Area ( 2.500 ) 334.25
Total Perm. FAR area 334.25
Residential FAR 252.43
Proposed FAR Area 261.05
Total Proposed FAR Area 261.05
Consumed FAR (Factor) 1.95
Balance FAR Area 73.20
BUA CHECK
Total Proposed BuiltUp Area 336.35


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0 -
Plot size (as per measurement) 133.82 133.70
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 13.37 18.98 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 18.98 0.00 0.00 - 1.41 - 85.66 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 5 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
RESIDENTIAL BUILDING (BUILDING) Residential Residential Bldg/Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
RESIDENTIAL BUILDING (BUILDING) 12.15 11.41 11.41 11.41 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RESIDENTIAL BUILDING (BUILDING) Third Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Second Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
First Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Ground Floor 2.75 - 2.85 2.75 - 2.75 2.40 - 2.47 OK
Basement Floor 2.40 - 2.80 2.40 - 2.70 2.10 - 2.42 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RESIDENTIAL BUILDING (BUILDING) Terrace Floor - - 1.07 - - 0.97 - - 0.97 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height of Basement Floor above GL Area Ventilation Area Status
Reqd Perm Prop Perm Prop Reqd Prop
RESIDENTIAL BUILDING (BUILDING) Basement Floor 0.90 1.50 1.21 - 63.96 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
RESIDENTIAL BUILDING (BUILDING) - 63.96
Total - 63.96 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  RESIDENTIAL BUILDING-1 (BUILDING)   6.10 M WIDE MAINROAD Access Road 2.00 3.00 1.50 1.50 0.90 0.90 0.90 0.90 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
RESIDENTIAL BUILDING (BUILDING) G + 4 4 - 8 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
RESIDENTIAL BUILDING (BUILDING) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
80.22 63.96 OK
60% 47.84%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  RESIDENTIAL BUILDING-1 (BUILDING) - 63.96
  Total Prop. Coverage Area - 63.96
  Total Coverage Area 80.22 63.96

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Accessory Use Parking Resi. Stair
RESIDENTIAL BUILDING (BUILDING) 1 336.35 13.08 10.15 52.06 252.43 8.63 261.06 261.06 08
Grand Total : 1 336.35 13.08 10.15 52.06 252.43 8.63 261.06 261.06 08


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
RESIDENTIAL BUILDING (BUILDING)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 63.96 8.63 63.96 8.63
Ground Floor 63.95 61.42 63.95 61.42
First Floor 69.48 63.67 69.48 63.67
Second Floor 69.48 63.67 69.48 63.67
Third Floor 69.48 63.67 69.48 63.67
Terrace Floor 0.00 0.00 0.00 0.00
Total : 336.35 261.06 336.35 261.06


[-] UnitBUA Table for Building :RESIDENTIAL BUILDING (BUILDING)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN 01 FLAT 24.64 24.55 4 2
02 FLAT 23.27 23.16 3
TYPICAL - 1, 2& 3 FLOOR PLAN F1 FLAT 28.57 28.48 4 6
F2 FLAT 24.96 24.85 3
Total: - - 208.52 207.70 28 8


[-] Building :RESIDENTIAL BUILDING (BUILDING)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Accessory Use Parking Resi. Stair
Basement Floor 63.96 3.27 0.00 52.06 0.00 8.63 8.63 8.63 00
Ground Floor 63.95 0.00 2.53 0.00 61.42 0.00 61.42 61.42 02
First Floor 69.48 3.27 2.54 0.00 63.67 0.00 63.67 63.67 02
Second Floor 69.48 3.27 2.54 0.00 63.67 0.00 63.67 63.67 02
Third Floor 69.48 3.27 2.54 0.00 63.67 0.00 63.67 63.67 02
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 336.35 13.08 10.15 52.06 252.43 8.63 261.06 261.06 08
Total Number of Same Buildings : 1
Total : 336.35 13.08 10.15 52.06 252.43 8.63 261.06 261.06 08
[-] Table 4c-2

  FAR Area
Building FAR Area:261.05
Existing FAR Area :0.00
Perm.
334.25
Prop.
261.05
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
RESIDENTIAL BUILDING-1 (BUILDING) 6.10 M WIDE MAINROAD Access Road 3.00 3.00 1.50 1.50 0.90 0.90 0.90 0.90 OK






[-] Inner Building Details (Table 6)
   
   
[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Number Of Strature Lift(s) Capacity Of Lift(s) Passanger Status
Prop Reqd Prop Reqd Prop Reqd Prop
RESIDENTIAL BUILDING (BUILDING) 11.41 - 1 - 0 - 6 OK

[-] Lift Check Table

[-] For Building :RESIDENTIAL BUILDING (BUILDING)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.71 1.90 1.91 OK
BASEMENT FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
GROUND FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK
TYPICAL - 1, 2& 3 FLOOR PLAN Lift 1.70 1.71 1.90 1.91 OK

   


[-] Parking Details (Table 7)
   
[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
RESIDENTIAL BUILDING (BUILDING) Residential Residential Bldg/Apartment > 0 1 8.00 1 8 - - - - - - -
> 0 1 8.00 - - - - - - 1 8 -
> 0 1 8.00 - - - 1 1 - - - -
Total : - - - - 8 8 - 1 1 - 8 8

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 2 25.00 OK
Four Stack.Car - - 6 75.00 OK
Total Car 8 100.00 8 100.00 OK
Visitor's Car Parking - - 1 12.50 OK
Total Visitor Parking 1 12.50 1 12.50 OK
TwoWheeler - - 8 16.00 OK
Total TwoWheeler 8 16.00 8 16.00 OK
Other Parking - - - 23.56 OK
Total 128.50 168.06 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules


   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :RESIDENTIAL BUILDING (BUILDING)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE - 1.064 - 0.250 - 0.000 - 0 - - 2.590 OK
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.064 0.250 0.250 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.064 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 1, 2& 3 FLOOR PLAN STAIRCASE 0.900 1.064 0.250 0.250 0.200 0.143 - 10 - - 0.000 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
12.00 mt. long 1.59 mt. High 11.34 mt. Wide Natural Slope - 2.94 - 1.59 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
RESIDENTIAL BUILDING (BUILDING) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SUMP TANK - - 1.37 - - 0.86 - - 1.59 - - 0.00 OK
RAIN WATER HARVESTING - - 0.27 - - 0.58 - - 0.59 - - 0.00 OK
ENT.GATE - - 0.22 - - 0.10 - - 2.25 - - 0.00 OK
Entrance Lobby - 12.00 2.53 - - 0.93 - - 2.74 - - 0.00 OK
Entrance Lobby - 12.00 2.54 - - 0.93 - - 2.75 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
RESIDENTIAL BUILDING (BUILDING) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:RESIDENTIAL BUILDING (BUILDING)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1, 2& 3 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 133.70 OK
  Plot Width - 13.26 OK
  Plot Depth - 10.08 OK
  Access Width - 6.10 OK
  Plot Frontage - 12.97 OK
  Coverage Area 80.22 63.96 OK
  FAR Area
Bldg. FAR Area : 261.05
Sanctioned FAR Area :0.00
334.25 261.05 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) -
(2) The area of lift well shall not be counted for F.A.R calculation)
(3) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.21x3.59 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Foyer2.24x1.06 No Rule Defined
Room3.21x2.99 No Rule Defined
Room3.60x2.74 No Rule Defined
Toilet1.35x2.74 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.13x1.33 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}