No Image Found   

Check List Report

Jugsalai Municipality

Version Number: 1.0.73  
Version Date: 16/10/2020 
Report Generated On: 19-09-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJUGSALAI MUNICIPALITY
Inward_NoJMP/BP/0008/W12/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageJugsalai
Taluka16
Architect Details
Architect NameANOOP KUMAR
License No.JMP/ENG/0001/2020
Architect Address4503, CHEESE BERRY BLOCK , SAHARA GARDEN CITY ADITYAPUR, JAMSHEDPUR, JHARKHAND -831013
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1325
North -
South -
EastRoad Width - 8.0 MTR WIDE MAIN ROAD
West -
Owner's Details
NameM/S CREATION INFRATECH , PROPRIETOR :- SRI DIVESH DUBEY
AddressGANGOTRI COMPLEX SHOP NO:-7, WARD NO-14, STATION ROAD JUGSALAI, JAMSHEDPUR
Email IDcreationinfratech01@gmail.com
Mobile No9934328435
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 626.24
2 Plot area as per Document by Applicant 626.24
3 Physical area measured at site 626.24
4 Area as per Site Visit (Site Visit Report) 626.24
5Area as per Drawing 627.20

Area of Plot Considered : 626.24

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 626.24
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 626.24
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 542.05
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 84.19
84.19
Balance Plot Area 542.05

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 375.74
Proposed Coverage Area ( 46.53 % ) 291.42
Total Prop. Coverage Area ( 46.53 % ) 291.42
Balance coverage area ( 13.46 % ) 84.32
FAR CHECK
Perm. FAR Area ( 2.500 ) 1565.60
Total Perm. FAR area 1565.60
Residential FAR 1437.66
Proposed FAR Area 1437.66
Total Proposed FAR Area 1437.66
Consumed FAR (Factor) 2.30
Balance FAR Area 127.94
BUA CHECK
Total Proposed BuiltUp Area 1978.99


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 8 8.00
Proposed Road Width as per Master Plan 8 -
Road Widening Width 0 -
Plot size (as per measurement) 626.24 627.20
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 626.24 OK
Plot Width Mt. - - 30.36 OK
Plot Depth Mt. - - 20.66 OK
Access Width Mt. 6.10 - 8.00 OK
Plot Frontage Mt. - - 31.62 OK
Coverage Area Sq.Mt. - 375.74 291.42 OK
FAR Area Sq.Mt. - 1565.60 1437.66 OK
Consumed FAR Sq.Mt. - 2.50 2.30 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 62.62 84.19 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 84.19 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.06 OK
Tree Cover (Plantation) - Angle Degree - 78.44 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 18 OK
Car In Area Sq.Mt. - - 75.00 OK
Two Stack.Car In Area Sq.Mt. - - 75.00 OK
Total Car In Area Sq.Mt. 312.50 - 150.00 Failed
Total Visitor Parking In Area Sq.Mt. 37.50 - 40.50 OK
Parallel Visitor's Car Parking In Area Sq.Mt. - - 40.50 OK
TwoWheeler In Area Sq.Mt. - - 54.00 OK
Total TwoWheeler In Area Sq.Mt. 50.00 - 54.00 OK
Other Parking In Area Sq.Mt. - - 185.94 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.00 - 3.67 OK
PLOT - - - DRIVEWAY - Width No. 3.00 - 3.70 OK
PLOT - - - DRIVEWAY - Width No. 3.00 - 3.70 OK
PLOT - - - DRIVEWAY - Width No. 3.00 - 3.59 OK
A (PRAVESH ENCLAVE) - BASEMENT FLOOR PLAN - DRIVEWAY - Width No. 3.60 - 3.33 Failed
A-1 (PRAVESH ENCLAVE) Front Margin... 8.0 MTR WIDE MAIN ROAD Mt. 3.00 - 3.72 OK
Rear Margin Mt. 2.00 - 3.11 OK
Side1 Margin Mt. 3.00 - 3.08 OK
Side2 Margin Mt. 3.00 - 3.17 OK
A-1 (PRAVESH ENCLAVE) Basement Front Margin... 8.0 MTR WIDE MAIN ROAD Mt. 2.00 - 3.72 OK
Basement Rear Margin Mt. 2.00 - 2.95 OK
Basement Side1 Margin Mt. 2.00 - 3.03 OK
Basement Side2 Margin Mt. 2.00 - 3.17 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (PRAVESH ENCLAVE) Height Mt. 15.72 14.25 OK
A (PRAVESH ENCLAVE) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.77 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.77 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.77 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.77 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.77 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.61 OK
Basement Floor - Height Mt. 2.40 - 2.85 OK
Basement Floor - Clear Height Mt. 2.40 - 2.77 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.61 OK
A (PRAVESH ENCLAVE) Terrace Floor - Height Mt. - - 1.07 OK
Terrace Floor - Clear Height Mt. - - 1.07 OK
Terrace Floor - Beam Clear Height Mt. - - 1.07 OK
A (PRAVESH ENCLAVE) Basement Floor - Height of Basement Floor above GL Mt. 0.90 1.50 1.00 OK
Basement Floor - Area Sq.Mt. - 319.55 OK
Basement Floor - Ventilation Area Sq.Mt. - - OK
A (PRAVESH ENCLAVE) Area Sq.Mt. - 319.55 OK
Status - OK
Total Area Sq.Mt. - 319.55 OK
A (PRAVESH ENCLAVE) No. of Basement Floor No. 1 1 OK
A (PRAVESH ENCLAVE) No. of Floors No. G + 5 5 OK
No. of Tenements No. - 25 OK
A (PRAVESH ENCLAVE) TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - BALCONY - Width Mt. 1.20 0.90 OK
A (PRAVESH ENCLAVE) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 13 OK
A (PRAVESH ENCLAVE) GROUND FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.45 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.98 OK
BASEMENT FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.45 OK
BASEMENT FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.98 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.45 OK
FIRST FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.98 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 2.45 OK
TYPICAL - 2, 3 & 4 FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.98 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.15 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 2.68 OK
GROUND FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 0.958 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.227 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 0.958 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.227 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TYPICAL - 2, 3 & 4 FLOOR PLAN Fire Escape Staircase - Flight Width Mt. 0.900 0.958 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
Fire Escape Staircase - Flight Width Mt. 0.900 1.227 OK
Fire Escape Staircase - Tread Width Mt. 0.250 0.268 OK
Fire Escape Staircase - Riser Height Mt. 0.200 0.142 OK
Fire Escape Staircase - Riser No. On Flight No. 16 10 OK
Fire Escape Staircase - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Fire Escape Staircase - Flight Width Mt. - 0.958 OK
Fire Escape Staircase - Tread Width Mt. - 0.268 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.500 OK
Fire Escape Staircase - Flight Width Mt. - 1.227 OK
Fire Escape Staircase - Tread Width Mt. - 0.268 OK
Fire Escape Staircase - Riser Height Mt. - - OK
Fire Escape Staircase - Riser No. On Flight No. 16 - OK
Fire Escape Staircase - Cabin Ht. Mt. - - 2.500 OK
Toilet Area Sq.Mt. - 5.00 2.11 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 1.72 OK
Height Mt. - - - OK
SewageTreatmentPlant Area Sq.Mt. - - 2.11 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 1.72 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.49 OK
Width Mt. - - 0.87 OK
Depth Mt. - - 1.71 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.93 OK
Width Mt. - - 0.45 OK
Depth Mt. - - 2.06 OK
Height Mt. - - - OK
GUARDROOM Area Sq.Mt. - 10.00 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 8.66 OK
Width Mt. - - 2.45 OK
Depth Mt. - - 3.53 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.66 OK
Width Mt. - - 2.45 OK
Depth Mt. - - 3.53 OK
Height Mt. - - - OK
Area Sq.Mt. - 12.00 8.66 OK
Width Mt. - - 2.45 OK
Depth Mt. - - 3.53 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 3.35 OK
Width Mt. - - 1.31 OK
Depth Mt. - - 2.56 OK
Height Mt. - - - OK
A (PRAVESH ENCLAVE) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 2.00 mt. long 0.45 mt. High 3.62 mt. Wide Natural Slope - Width Mt. - 2.00 OK
2.00 mt. long 0.45 mt. High 3.62 mt. Wide Natural Slope - Depth Mt. - 0.45 OK
2.00 mt. long 0.45 mt. High 3.62 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (PRAVESH ENCLAVE) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JUGSALAI MUNICIPALITY, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) The minimum width of the drive way meant exclusively for 2 wheelers should be 3.0 mt {As per Rule No. 41.2}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 2.0 mt. and 3.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height The minimum height of the ceiling of upper basement shall be 0.90m. and the maximum, 1.5 m. above the average surrounding ground level {As per Rule No. 48},
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony Projected balcony may be allowed with a widt of 1.2 mt. where the setback is more than 2.5 mt. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(2) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(3) No Rule Defined
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SewageTreatmentPlant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARDROOM
(10) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(11) No need to check distance from Building Entrance Lobby
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)
Bed Room3.03x3.26 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.07x4.64 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.28x3.07 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.38x3.08 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room3.76x4.79 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Bed Room4.29x2.80 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Kitchen1.99x2.99 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen2.46x2.26 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen2.80x2.04 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Kitchen2.91x1.96 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Living/dining0.73x1.26 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Living/dining2.57x1.34 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Living/dining2.57x2.38 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Living/dining2.91x2.61 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Living/dining3.76x2.38 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Toilet2.06x1.69 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.27x1.57 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.30x1.73 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.45x1.23 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.46x1.23 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}
Toilet2.46x1.38 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}