Topic |
Rule |
Plot Level |
Plot Area |
The minimum size of plot for Petrol Pump/Filling station, Only for filling station category shall be 500.0 sq.mt. with size of 30 mt. x 20 mt.haaving Mini. 30 mt. frontage {As per Chapter VII 66.3}
|
Plot Width |
The minimum size of plot for Petrol Pump/Filling station, Only for filling station category shall be 500.0 sq.mt. with size of 30 mt. x 20 mt.haaving Mini. 30 mt. frontage {As per Chapter VII 66.3}
|
Plot Depth |
The minimum size of plot for Petrol Pump/Filling station, Only for filling station category shall be 500.0 sq.mt. with size of 30 mt. x 20 mt.haaving Mini. 30 mt. frontage {As per Chapter VII 66.3}
|
Access Width |
The minimum width of abutting road for Petrol Pump/Filling station, shall be 30.0 mt. {As per Chapter VII 66.3}
|
Plot Frontage |
The minimum size of plot for Petrol Pump/Filling station, Only for filling station category shall be 500.0 sq.mt. with size of 30 mt. x 20 mt.haaving Mini. 30 mt. frontage {As per Chapter VII 66.3}
|
FAR Area |
(1)
For Petrol Pump with or without Service Station, the Floor Area Ratio-FAR shall be 1.0 {As per Chapter VII 66.6}
(2)
For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Consumed FAR |
(1)
For Petrol Pump with or without Service Station, the Floor Area Ratio-FAR shall be 1.0 {As per Chapter VII 66.6}
(2)
For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
(3)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4)
;
|
Tree Number |
Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Malls and Multiplex, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.5}
|
Building Level |
Building Height |
For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2)
The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Floor Number |
For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
|
Plot / Building Level |
Accessory Use |
(1)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2)
No need to check distance from Building RAIN WATER HARVESTING
|
Accessory Use Number |
Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
|
Building Level (Rooms) |