No Image Found

Check List Report

Jamshedpur NAC

Version Number: 1.0.17
Version Date: 16/10/2017
Report Generated On: 13-11-2017

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0043/W2/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKADMA
Taluka16
Architect Details
Architect NameLAWRENCE FRANCIS
License No.JNAC/ARC/0003/2016
Architect AddressH. NO. 114, ROAD NO. 4, SONARI WEST LAYOUT
Architect EmailIDlawrencekunj@gmail.com
Architect Mobile No8294163462
Plot Details
Plot Use Assembly
Plot SubUse Auditorium
PlotNearbyReligiousStructure NA
Plot/SubPlot No1397(P),1402,1403
NorthRoad Width - 17
SouthRoad Width - 18
EastRoad Width - 18
WestPlot No. - D.B.M.S KADMA GIRLS HIGH SCHOOL
Owner's Details
NameMS TATA STEEL LIMITED JAMSHEDPUR
AddressJUSCO SCHOOL KADMA, NEW PLOT NO.- 1397(P),1402,1403, WARD NO.- 2, KHATA NO.-1217, JAMSHEDPUR, DIST- EAST SINGHBHUM JHARKHAND
Email IDamit.singh1206@gmail.com
Mobile No7763807105
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 14006.20
2 Plot area as per Document by Applicant 14006.20
3 Physical area measured at site 14006.20
4 Area as per Site Visit (Site Visit Report) 14006.20
5Area as per Drawing 3662.99

Area of Plot Considered : 3662.99

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyAssembly
Plot SubUse Auditorium
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 3662.99
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 3662.99
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 3280.20
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 382.79
382.79
Balance Plot Area 3280.20

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1831.49
Proposed Coverage Area ( 21.95 % ) 804.15
Total Prop. Coverage Area ( 21.95 % ) 804.15
Balance coverage area ( 28.05 % ) 1027.34
FAR CHECK
Perm. FAR Area ( 2.25 ) 8241.72
Total Perm. FAR area 8241.72
Special FAR 804.15
Proposed FAR Area 804.15
Total Proposed FAR Area 804.15
Consumed FAR (Factor) 0.22
Balance FAR Area 7437.57
BUA CHECK
Total Proposed BuiltUp Area 804.15


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road -
Existing Road Width 17 17.00
Proposed Road Width as per Master Plan 17 -
Road Widening Width 0.001 -
Plot size (as per measurement) 14006.2 3662.99


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 1000.00 - 3662.99 OK
Plot Width Sq.Mt. - - 66.67 OK
Plot Depth Sq.Mt. - - 54.94 OK
Access Width Sq.Mt. 12.20 - 17.00 OK
Plot Frontage Sq.Mt. - - 62.28 OK
Coverage Area Sq.Mt. - 1831.49 804.15 OK
FAR Area Sq.Mt. - 8241.72 804.15 OK
Consumed FAR Sq.Mt. - 2.25 0.22 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 366.30 382.79 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 382.79 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 8.76 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 8 14 OK
Car In Area Sq.Mt. 250.00 - 412.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 62.50 OK
TwoWheeler In Area Sq.Mt. 126.00 - 130.00 OK
Other Parking In Area Sq.Mt. - - 585.03 OK
A-1 (JUSCO AUDITORIUM) Front Margin... 17.00 mt. Wide MainRoad Mt. 12.00 - 12.01 OK
Rear Margin Mt. 6.00 - 6.20 OK
Side1 Margin Mt. 6.00 - 13.19 OK
Side2 Margin Mt. 6.00 - 15.37 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (JUSCO AUDITORIUM) Height Mt. 30.00 6.15 OK
A (JUSCO AUDITORIUM) Ground Floor - Height Mt. 2.75 - 6.15 OK
A (JUSCO AUDITORIUM) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (JUSCO AUDITORIUM) No. of Floors No. - 1 OK
No. of Tenements No. - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 12.34 OK
Width Mt. - - 3.43 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
Area Sq.Mt. - - 12.34 OK
Width Mt. - - 3.43 OK
Depth Mt. - - 3.60 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.15 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 5.00 OK
Height Mt. - - - OK
GUARD ROOM Area Sq.Mt. - 10.00 8.28 OK
Width Mt. - - 2.45 OK
Depth Mt. - - 3.38 OK
Height Mt. - - - OK
A (JUSCO AUDITORIUM) Rain Water Harvesting - No No. 1 - 2 OK
Entrance Gate - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High rise building (building with a height of 16.40 meters and above) shall be 1000.0 sq.mt.{As per Rule No. 35.1, Note 4}
Plot Width The minimum size of plot for High rise building (building with a height of 16.40 meters and above) shall be 1000.0 sq.mt.{As per Rule No. 35.1, Note 4}
Plot Depth The minimum size of plot for High rise building (building with a height of 16.40 meters and above) shall be 1000.0 sq.mt.{As per Rule No. 35.1, Note 4}
Access Width The minimum width of abutting road for Place of congregation, Community Hall category shall be 12.20 mt.{As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for High rise building (building with a height of 16.40 meters and above) shall be 1000.0 sq.mt.{As per Rule No. 35.1, Note 4}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Assembly Building, Margin required in Front shall be 12.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.3}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(5) No need to check distance from Building GUARD ROOM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)