No Image Found

Check List Report

Jamshedpur NAC

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 23-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority JAMSHEDPUR NAC
Inward_No JNAC/BP/0076/W2/2017
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village SONARI
Taluka 16
Architect Details
Architect Name L K Suman
License No. JNAC/ENG/0006/2016
Architect Address 2nd Floor Basant Talkies complax, sakchi jamshedpur
Architect EmailID lksumanoffice@gmail.com
Architect Mobile No 9835131161
Plot Details
Plot Use Residential
Plot SubUse Individual Row House
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1345-B, B/BLOCK
North Plot No. - ALLEY
South Road Width - 4.87
East Plot No. - 1345-C
West Plot No. - 1345-A
Owner's Details
Name SRI ARVIND KUMAR
Address 1345-B, B/ Block, Sonari, Jamshedpur
Email ID maalakshmi24@rediffmail.com
Mobile No 7250774003
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 67.93
2 Plot area as per Document by Applicant 67.88
3 Physical area measured at site 67.88
4 Area as per Site Visit (Site Visit Report) 67.74
5 Area as per Drawing 67.53

Area of Plot Considered : 67.53

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Individual Row House
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 67.53
Deduction from Gross Plot area
- Extra Land Area 3.84
3.84
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 63.69
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 56.42
Deductions for Balance Plot Area (from Gross Plot Area)
- Extra Land Area 3.84
- Common Plot 7.27
11.11
Balance Plot Area 56.42

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 44.58
Proposed Coverage Area ( 58.77 % ) 37.43
Total Prop. Coverage Area ( 58.77 % ) 37.43
Balance coverage area ( 11.23 % ) 7.15
FAR CHECK
Perm. FAR Area ( 1.50 ) 95.53
Total Perm. FAR area 95.53
Residential FAR 74.87
Proposed FAR Area 86.38
Total Proposed FAR Area 86.38
Consumed FAR (Factor) 1.36
Balance FAR Area 9.15
BUA CHECK
Total Proposed BuiltUp Area 112.29


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 4.65 4.65
Proposed Road Width as per Master Plan 4.65 -
Road Widening Width 0.015 0.72
Plot size (as per measurement) 67.74 67.53


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. 50.00 - 63.69 OK
Plot Width Sq.Mt. - - 5.33 OK
Plot Depth Sq.Mt. - - 11.95 OK
Access Width Sq.Mt. - - 4.65 OK
Plot Frontage Sq.Mt. - - 5.33 OK
Coverage Area Sq.Mt. - 44.58 37.43 OK
FAR Area Sq.Mt. - 95.53 86.38 OK
Consumed FAR Sq.Mt. - 1.50 1.36 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 3.18 7.27 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 7.27 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.41 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 3 OK
A-1 (SRI ARVIND KUMAR) Front Margin... Extra Land Mt. 2.00 - 2.00 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 0.90 OK
Side2 Margin Mt. - - 0.00 OK
A-1 (SRI ARVIND KUMAR) BldgLine for 4.65 m WD ROAD Mt. 0.72 2.72 OK
A-1 (SRI ARVIND KUMAR) ResvRoad Width Check for... 4.65 m WD ROAD Mt. 0.72 0.72 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (SRI ARVIND KUMAR) Height Mt. 9.70 8.25 OK
A (SRI ARVIND KUMAR) Second Floor - Height Mt. 2.75 - 2.75 OK
First Floor - Height Mt. 2.75 - 2.75 OK
Ground Floor - Height Mt. 2.75 - 2.75 OK
A (SRI ARVIND KUMAR) Terrace Floor - Height Mt. 1.00 1.20 1.10 OK
A (SRI ARVIND KUMAR) No. of Floors No. G + 2 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.196 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.196 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.200 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.196 OK
STAIRCASE - Riser No. On Flight No. - 7 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.200 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 1.600 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Plot Width The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Plot Depth The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 100 mt. and upto 300 mt. shall be 6.1 mt. {As per Rule No. 34 Table No. 6 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Building Level (Rooms)