-
No Image Found

Check List Report

Jamshedpur NAC

Version Number: 1.0.29
Version Date: 30/06/2018
Report Generated On: 12-10-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0107/W2/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBHATIA
Taluka16
Architect Details
Architect NameMUKESH KUMAR
License No.JNAC/ENG/0003/2017
Architect AddressBistupur Jamshedpur
Architect EmailIDsrishtidesigner@rediffmail.com
Architect Mobile No9934333171
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1474
NorthCTS No. - BHATIA PARK
SouthCTS No. - OTHERS PLOT
EastCTS No. - BHATIA PARK
WestRoad Width - 6.10
Owner's Details
NameCHANDAN MITTAL
AddressH. NO. -13 , RIVER VIEW BANK COLONY , BESIDE BHATIYA PARK , KADMA , P. O. & P. S. - KADMA , JAMSHEDPUR.
Email IDchandanmittal@yahoo.com
Mobile No9234600100
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 408.84
2 Plot area as per Document by Applicant 408.77
3 Physical area measured at site 408.77
4 Area as per Site Visit (Site Visit Report) 394.00
5Area as per Drawing 393.98

Area of Plot Considered : 393.98

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 393.98
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 393.98
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 321.10
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 72.89
72.89
Balance Plot Area 321.10

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 236.39
Proposed Coverage Area ( 40.56 % ) 159.79
Total Prop. Coverage Area ( 40.56 % ) 159.79
Balance coverage area ( 19.44 % ) 76.60
FAR CHECK
Perm. FAR Area ( 2.50 ) 984.95
Total Perm. FAR area 984.95
Residential FAR 626.24
Proposed FAR Area 642.01
Total Proposed FAR Area 642.01
Consumed FAR (Factor) 1.63
Balance FAR Area 342.94
BUA CHECK
Total Proposed BuiltUp Area 798.95


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 394 393.98


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 393.98 OK
Plot Width Sq.Mt. - - 25.00 OK
Plot Depth Sq.Mt. - - 15.76 OK
Access Width Sq.Mt. 6.10 - 6.10 OK
Plot Frontage Sq.Mt. - - 20.51 OK
Coverage Area Sq.Mt. - 236.39 159.79 OK
FAR Area Sq.Mt. - 984.95 642.01 OK
Consumed FAR Sq.Mt. - 2.50 1.63 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 39.40 72.89 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 72.89 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.94 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 11 OK
Car In Area Sq.Mt. - - 50.00 OK
Three Stack.Car In Area Sq.Mt. - - 100.00 OK
Total Car In Area Sq.Mt. 150.00 - 150.00 OK
Visitor's Car Parking In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. 24.00 - 48.00 OK
Other Parking In Area Sq.Mt. - - 84.02 OK
A-1 (BUILDING) Front Margin... 6.10 M WIDE ROAD Mt. 3.00 - 4.75 OK
Rear Margin Mt. 3.00 - 3.01 OK
Side1 Margin Mt. 2.50 - 2.53 OK
Side2 Margin Mt. 2.50 - 2.50 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) Height Mt. 13.90 13.75 OK
A (BUILDING) Fourth Floor - Height Mt. 2.75 - 2.75 OK
Third Floor - Height Mt. 2.75 - 2.75 OK
Second Floor - Height Mt. 2.75 - 2.75 OK
First Floor - Height Mt. 2.75 - 2.75 OK
Parking Floor - Height Mt. - - 2.75 OK
Plinth - Height Mt. - - 0.15 OK
A (BUILDING) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (BUILDING) No. of Floors No. P + 4 5 OK
No. of Tenements No. - 12 OK
A (BUILDING) TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Passage Name - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Width Mt. 1.00 1.07 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Length Mt. - 7.88 OK
A (BUILDING) Number Of Lift(s) No. 1 1 OK
A (BUILDING) PARKING FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
PARKING FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
PARKING FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.137 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.137 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.219 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.591 OK
SUMP TANK Area Sq.Mt. - - 3.35 OK
Width Mt. - - 1.83 OK
Depth Mt. - - 1.83 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.17 OK
Width Mt. - - 1.22 OK
Depth Mt. - - 1.22 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.30 OK
Width Mt. - - 0.34 OK
Depth Mt. - - 3.78 OK
Height Mt. - - - OK
A (BUILDING) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
A (BUILDING) TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.82 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.82 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.37 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.62 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.37 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.62 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.37 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.62 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.13 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.96 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 2.43 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 1.09 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.57 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.71 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.57 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
TERRACE FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TERRACE FLOOR PLAN - CHHAJJA - Depth Mt. - 1.57 OK
TERRACE FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.71 OK
TERRACE FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.45 OK
TERRACE FLOOR PLAN - CHHAJJA - Depth Mt. - 1.57 OK
TERRACE FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 15-21 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 3.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
(4) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)