Detail Scrutiny Report

Jamshedpur NAC

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 24-08-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0081/W1/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSONARI
Taluka16
Architect Details
Architect NameAnoop Kumar
License No.JNAC/ENG/0005/2016
Architect AddressFlat No.- 4503, Cheese Berry, Shara Garden City-Adityapur-II
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3173(N)
North -
South -
East -
West -
Owner's Details
Name SMT. ANIMA SUR, SRI. KALI PRASAD SUR, SMT. PRBHABATI SUR, SRI. GOUTAM SUR, MISS. KAKOLI SUR, SMT. PAPIYA SUR & SMT. PIYALI SUR
AddressSONARY , JAMSHEDPUR
Email IDRAVIM76@GMAIL.COM
Mobile No9199222161
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 213.17
2 Plot area as per Document by Applicant 213.17
3 Physical area measured at site 213.23
4 Area as per Site Visit (Site Visit Report) 213.17
5Area as per Drawing 213.17

Area of Plot Considered : 213.17

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 213.17
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 213.17
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 187.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 25.62
25.62
Balance Plot Area 187.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 149.22
Proposed Coverage Area ( 65.33 % ) 139.26
Total Prop. Coverage Area ( 65.33 % ) 139.26
Balance coverage area ( 4.67 % ) 9.96
FAR CHECK
Perm. FAR Area ( 2.50 ) 532.92
Total Perm. FAR area 532.92
Residential FAR 417.78
Proposed FAR Area 417.78
Total Proposed FAR Area 417.78
Consumed FAR (Factor) 1.96
Balance FAR Area 115.14
BUA CHECK
Total Proposed BuiltUp Area 417.78


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 213.17 213.17




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 10.66 25.62 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 25.62 0.00 0.00 - 1.40 - 89.58 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 15 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI KALI PRASAD SUR OTHERS) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI KALI PRASAD SUR OTHERS) 21.02 9.14 9.14 9.14 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI KALI PRASAD SUR OTHERS) Second Floor 2.75 - 3.05 OK
First Floor 2.75 - 3.05 OK
Ground Floor 2.75 - 3.05 OK
Plinth 0.45 - 0.76 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (SRI KALI PRASAD SUR OTHERS) Terrace Floor 1.00 1.20 1.05 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI KALI PRASAD SUR OTHERS) G + 6 3 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
149.22 139.26 OK
70% 65.33%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (SRI KALI PRASAD SUR OTHERS) - 139.26
Total Prop. Coverage Area - 139.26
Total Coverage Area 149.22 139.26


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A (SRI KALI PRASAD SUR OTHERS) 1 417.78 417.78 417.78 417.78 01
Grand Total : 1 417.78 417.78 417.78 417.78 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI KALI PRASAD SUR OTHERS)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 139.26 139.26 139.26 139.26
First Floor 139.26 139.26 139.26 139.26
Second Floor 139.26 139.26 139.26 139.26
Terrace Floor 0.00 0.00 0.00 0.00
Total : 417.78 417.78 417.78 417.78


[-] UnitBUA Table for Building :A (SRI KALI PRASAD SUR OTHERS) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT SRI KALI PRASAD SUR & OTHERS FLAT 313.25 313.00 6 1
TYPICAL - 1 & 2 FLOOR PLAN SPLIT SRI KALI PRASAD SUR & OTHERS FLAT 0.00 0.00 9 0
Total: - - 313.25 313.00 24 1


[-] Building :A (SRI KALI PRASAD SUR OTHERS)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 139.26 139.26 139.26 139.26 01
First Floor 139.26 139.26 139.26 139.26 00
Second Floor 139.26 139.26 139.26 139.26 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 417.78 417.78 417.78 417.78 01
Total Number of Same Buildings : 1
Total : 417.78 417.78 417.78 417.78 01

[-] Table 4c-2

FARArea
Building FAR Area:417.78
Existing FAR Area :0.00
Perm.
532.92
Prop.
417.78
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI KALI PRASAD SUR OTHERS) 12 MTR WIDE ROAD Access Road 3.00 3.02 1.80 2.03 0.90 0.93 - 0.02 OK







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (SRI KALI PRASAD SUR OTHERS)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI KALI PRASAD SUR OTHERS)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.162 0.250 0.305 0.200 0.152 - 10 - - 0.000 OK
TYPICAL - 1 & 2 FLOOR PLAN STAIRCASE 0.900 1.162 0.250 0.305 0.200 0.152 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.162 - 0.305 - 0.000 - 0 - - 2.439 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.92 - - 0.86 - - 1.07 - - 0.00 OK
RAIN WATER HARVESTING - - 1.96 - - 1.07 - - 1.83 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.96 - - 1.07 - - 1.83 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (SRI KALI PRASAD SUR OTHERS)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1 & 2 FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT SRI KALI PRASAD SUR & OTHERS TOILET 3.62X1.37 2.80 4.96 1.20 1.37 1.20 3.62 0.30 0.00 Failed





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 213.17 OK
Plot Width - 9.33 OK
Plot Depth - 22.84 OK
Access Width - 12.00 OK
Plot Frontage - 9.53 OK
Coverage Area 149.22 139.26 OK
FARArea
Bldg. FAR Area : 417.78
Sanctioned FAR Area :0.00
532.92 417.78 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)