Failed List Report

Jamshedpur NAC

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 14-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority JAMSHEDPUR NAC
Inward_No JNAC/BP/0076/W7/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village SAKCHI
Taluka 16
Architect Details
Architect Name Vineet Sinha
License No. JNAC/ARC/0020/2017
Architect Address F-4, 44 CH AREA, BISTUPUR
Architect EmailID vsinhas@gmail.com
Architect Mobile No 9162776535
Plot Details
Plot Use Educational
Plot SubUse College
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1357, 1358, 1359(P), 1360, 1361, 1362, 1363(P), 1364(P), 1365(P), 1366(P), 1367(P), 1368(P), 1369(P)
North Road Width - 7.5
South Road Width - 12.2
East Road Width - 12.2
West Road Width - 12.2
Owner's Details
Name TATA STEEL LTD.
Address Land office, TATA Steel Ltd, JUSCO main campus, Sakchi, Boulevard Road, Jamshedpur
Email ID arunkrsingh@tatasteel.com
Mobile No 7763807046
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 9983.17
2 Plot area as per Document by Applicant 9976.44
3 Physical area measured at site 9983.17
4 Area as per Site Visit (Site Visit Report) 9976.00
5 Area as per Drawing 9975.62

Area of Plot Considered : 9975.62

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Educational
Plot SubUse College
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 9975.62
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 9975.62
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 8841.43
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 1134.19
1134.19
Balance Plot Area 8841.43

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 4987.81
Proposed Coverage Area ( 24.67 % ) 2461.24
Total Prop. Coverage Area ( 24.67 % ) 2461.24
Balance coverage area ( 25.33 % ) 2526.57
FAR CHECK
Perm. FAR Area ( 2.25 ) 22445.14
Total Perm. FAR area 22445.14
Special FAR 6218.45
Proposed FAR Area 6269.63
Total Proposed FAR Area 6269.63
Consumed FAR (Factor) 0.63
Balance FAR Area 16175.51
BUA CHECK
Total Proposed BuiltUp Area 6286.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 9976 9975.62





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for College category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for College category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for College category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for College category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for College category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Educational Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.1}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(2) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
VShaft For Building upto 12.0 mt. Ht.,Size of Ventilation shaft shall be 2.8 sq.mt. with mini 1.2 mt. width {As per clause-8.2.5(b), Part-3 of National Building Code of India}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, No Lift is reqd for Building upto G+2 floor {As per Rule No. 49.2.2}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(2) No need to check distance from Building TRANSFORMER
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.0 M. DEPTH
(5) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(6) No need to check distance from Building ELECTRIC SUBSTATION
(7) No need to check distance from Building ENT.GATE
(8) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(9) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)