No Image Found   

Failed List Report

Jamshedpur NAC

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 10-02-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0106/W11/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSitaramdera
Taluka16
Architect Details
Architect NameAjit Kumar Dhar
License No.JNAC/DFTMN/0009/2017
Architect Address36-A, New Sitaramdera, Jamshedpur,
Architect EmailIDajit06dhar.@gmail.com
Architect Mobile No9431301017
Plot Details
Plot Use Residential
Plot SubUse Semidetached
PlotNearbyReligiousStructure NA
Plot/SubPlot No272
NorthPlot No. - 273
SouthPlot No. - 271
EastRoad Width - 9.0
WestRoad Width - 4.50
Owner's Details
NameSRI MAHENDRA
AddressH.NO. - 272, BHALUBASA AREA, JAMSHEDPUR
Email IDajit06dhar@gmail.com
Mobile No7301125484
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 70.61
2 Plot area as per Document by Applicant 70.61
3 Physical area measured at site 70.61
4 Area as per Site Visit (Site Visit Report) 70.50
5Area as per Drawing 70.03

Area of Plot Considered : 70.03

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Semidetached
Building StructureNon-Highrise
Building TypeSingle Semi-Detached House
Gross Plot Area 70.03
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 70.03
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 56.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 13.48
13.48
Balance Plot Area 56.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 49.02
Proposed Coverage Area ( 60.02 % ) 42.03
Total Prop. Coverage Area ( 60.02 % ) 42.03
Balance coverage area ( 9.98 % ) 6.99
FAR CHECK
Perm. FAR Area ( 2.50 ) 175.07
Total Perm. FAR area 175.07
Residential FAR 84.06
Proposed FAR Area 93.19
Total Proposed FAR Area 93.19
Consumed FAR (Factor) 1.33
Balance FAR Area 81.88
BUA CHECK
Total Proposed BuiltUp Area 126.09


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 70.5 70.03
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For Row house, Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 8.55 mt. {As per Chapter VII}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Building Level (Rooms)