Failed List Report

Jamshedpur NAC

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 07-01-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0137/W2/2021
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageULIYAN
Taluka16
Architect Details
Architect NameSUDIPTO MUKHERJEE
License No.JNAC/ENG/0013/2019
Architect AddressHo. No. 1A, CLASSIC APARTMENT, NEW BARADWARI, P.O. SAKCHI, JAMSHEDPUR, EAST SINGHBHUM
Architect EmailIDsudipto_mukherg@yahoo.co.in
Architect Mobile No9431348519
Plot Details
Plot Use Residential
Plot SubUse Row House
PlotNearbyReligiousStructure NA
Plot/SubPlot NoDUPLEX No. 129, PLOT No. 1211 (O), 26 (N)
North -
South -
East -
West -
Owner's Details
NameJAISHREE SINHA AND HIRA LAL SINHA
AddressDUPLEX No. 129, VIJAYA HERITAGE, KADMA, JAMSHEDPUR
Email IDbhadanisuraj@yahoo.in
Mobile No9470155965
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 198.36
2 Plot area as per Document by Applicant 198.36
3 Physical area measured at site 198.36
4 Area as per Site Visit (Site Visit Report) 198.36
5Area as per Drawing 197.61

Area of Plot Considered : 197.61

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Row House
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 197.61
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 197.61
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 184.45
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 13.15
13.15
Balance Plot Area 184.45

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 138.33
Proposed Coverage Area ( 51.55 % ) 101.86
Total Prop. Coverage Area ( 51.55 % ) 101.86
Balance coverage area ( 18.46 % ) 36.47
FAR CHECK
Perm. FAR Area ( 2.50 ) 494.02
Total Perm. FAR area 494.02
Residential FAR 305.59
Proposed FAR Area 305.59
Total Proposed FAR Area 305.59
Consumed FAR (Factor) 1.55
Balance FAR Area 188.43
BUA CHECK
Total Proposed BuiltUp Area 305.58


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.25 6.25
Proposed Road Width as per Master Plan 0 -
Road Widening Width 0 -
Plot size (as per measurement) 198.36 197.61
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage The minimum size of plot for Row House shall be 50.0 sq.mt.{As per Chapter VII and Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For Row house, Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 8.55 mt. {As per Chapter VII}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING 1.80 DIA & 3.6 M DEPTH
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)