No Image Found   

Check List Report

Jamshedpur NAC

Version Number: 1.0.66  
Version Date: 16/10/2020 
Report Generated On: 12-08-2023 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0096/W1/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageSONARI
Taluka16
Architect Details
Architect NameSAPNA JAISWAL
License No.JNAC/ARC/0011/2019
Architect Address1421, Saraswati , Vijaya Shatabdi, Sonari Jamshedpur
Architect EmailIDsapna.jaiswal@tatasteel.com
Architect Mobile No7542029384
Plot Details
Plot Use Public Utility
Plot SubUse Sub-Station
PlotNearbyReligiousStructure NA
Plot/SubPlot No4587 (P)
NorthPlot No. - 4587(P)
SouthRoad Width - 12.20
EastRoad Width - 4
WestPlot No. - 4587(P)
Owner's Details
NameMS Tata Steel Ltd
AddressTata Steel Utilities & infrastructure Services Ltd, Power services, Northern Town, Sakchi Boulevard Road, Bistupur, Jamshedpur
Email IDmalay_panda@tatasteel.com
Mobile No9234557944
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 364.22
2 Plot area as per Document by Applicant 362.49
3 Physical area measured at site 362.49
4 Area as per Site Visit (Site Visit Report) 362.49
5Area as per Drawing 362.49

Area of Plot Considered : 362.49

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyPublic Utility
Plot SubUse Sub-Station
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 362.49
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 362.49
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 338.69
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 23.80
23.80
Balance Plot Area 338.69

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 217.49
Proposed Coverage Area ( 26.81 % ) 97.17
Total Prop. Coverage Area ( 26.81 % ) 97.17
Balance coverage area ( 33.19 % ) 120.32
FAR CHECK
Perm. FAR Area ( 2.500 ) 906.22
Total Perm. FAR area 906.22
Special FAR 153.27
Proposed FAR Area 153.27
Total Proposed FAR Area 153.27
Consumed FAR (Factor) 0.42
Balance FAR Area 752.95
BUA CHECK
Total Proposed BuiltUp Area 153.26


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 12.2 12.20
Proposed Road Width as per Master Plan 12.2 -
Road Widening Width 0 -
Plot size (as per measurement) 362.49 362.49
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 362.49 OK
Plot Width Mt. - - 16.20 OK
Plot Depth Mt. - - 22.38 OK
Access Width Mt. 9.00 - 12.20 OK
Plot Frontage Mt. - - 19.90 OK
Coverage Area Sq.Mt. - 217.49 97.17 OK
FAR Area Sq.Mt. - 906.22 153.27 OK
Consumed FAR Sq.Mt. - 2.50 0.42 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 18.12 23.80 OK
Common Plot Normal Open Space - Minimum Area Sq.Mt. - 23.80 OK
Normal Open Space - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 6 OK
Car In Area Sq.Mt. - - 25.00 OK
Total Car In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 10.00 OK
Total TwoWheeler In Area Sq.Mt. 8.00 - 10.00 OK
DriveWay PLOT - - - DRIVEWAY - Width No. 3.60 - 4.00 OK
SWITCH ROOM-1 (SUBSTATION BLOCK) Front Margin... 12.2M WIDE MAINROAD Access Road Mt. 6.00 - 6.07 OK
Rear Margin Mt. 4.00 - 4.11 OK
Side1 Margin Mt. 2.50 - 2.50 OK
Side2 Margin Mt. 2.50 - 2.50 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
SWITCH ROOM (SUBSTATION BLOCK) Height Mt. 24.37 7.00 OK
SWITCH ROOM (SUBSTATION BLOCK) First Floor - Height Mt. 2.75 - 3.50 OK
First Floor - Clear Height Mt. 2.75 - 3.38 OK
First Floor - Beam Clear Height Mt. 2.40 - 3.20 OK
Ground Floor - Height Mt. 2.75 - 3.50 OK
Ground Floor - Clear Height Mt. 2.75 - 3.40 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 3.20 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
SWITCH ROOM (SUBSTATION BLOCK) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
SWITCH ROOM (SUBSTATION BLOCK) No. of Floors No. - 2 OK
No. of Tenements No. - 2 OK
GROUND FLOOR PLAN Internal Staircase - Flight Width Mt. - 1.200 OK
Internal Staircase - Tread Width Mt. - 0.300 OK
Internal Staircase - Riser Height Mt. - 0.146 OK
Internal Staircase - Riser No. On Flight No. 14 12 OK
Internal Staircase - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Internal Staircase - Flight Width Mt. - 1.200 OK
Internal Staircase - Tread Width Mt. - 0.300 OK
Internal Staircase - Riser Height Mt. - 0.146 OK
Internal Staircase - Riser No. On Flight No. 14 12 OK
Internal Staircase - Cabin Ht. Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 7.93 OK
Width Mt. - - 1.67 OK
Depth Mt. - - 4.75 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.28 OK
Width Mt. - - 0.32 OK
Depth Mt. - - 4.00 OK
Height Mt. - - - OK
SWITCH ROOM (SUBSTATION BLOCK) Rain Water Harvesting - No No. 1 - 1 OK
SWITCH ROOM (SUBSTATION BLOCK) GROUND FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.30 OK
GROUND FLOOR PLAN - CHHAJJA - Depth Mt. - 0.90 OK
GROUND FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.27 OK
GROUND FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.30 OK
GROUND FLOOR PLAN - CHHAJJA - Depth Mt. - 1.20 OK
GROUND FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.36 OK
FIRST FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.30 OK
FIRST FLOOR PLAN - CHHAJJA - Depth Mt. - 1.20 OK
FIRST FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.36 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for Institutional, administrative, assembly, industrial and other Nonresidential and commercial activities shall be 9.0 mt.{As per Rule no. 34.5 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) No Rule Define.
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) No Rule Define.
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot ; ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 6.0 mt., Rear 4.0 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) No rule found for Mini. reqd Floor height
(2) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)