No Image Found   

Failed List Report

Jamshedpur NAC

Version Number: 1.0.64  
Version Date: 16/10/2020 
Report Generated On: 13-12-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0055/W19/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageNILDIH
Taluka16
Layout Sanction NoNIL
Layout Sanction Date10/1/1969
Architect Details
Architect NameL K Suman
License No.JNAC/ENG/0006/2016
Architect Address2nd Floor Basant Talkies complax, sakchi jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Educational
Plot SubUse Secondary-Higher Secondary School
PlotNearbyReligiousStructure NA
Plot/SubPlot NoNil
NorthRoad Width - 18.0
SouthRoad Width - 18
EastSurvey No. - OTHER PLOT
WestRoad Width - 18.0
Owner's Details
NameLITTLE FLOWER SCHOOL
AddressTelco Colony, Jamshedpur
Email IDvenugopal5191@gmail.com
Mobile No8877447744
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 20468.60
2 Plot area as per Document by Applicant 20468.59
3 Physical area measured at site 20468.60
4 Area as per Site Visit (Site Visit Report) 20468.59
5Area as per Drawing 20468.59

Area of Plot Considered : 20468.59

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyEducational
Plot SubUse Secondary-Higher Secondary School
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 20468.59
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 20468.59
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 15983.69
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 4484.90
4484.90
Balance Plot Area 15983.69

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 10234.29
Proposed Coverage Area ( 1.19 % ) 243.13
Existing Building Coverage area ( 26.28 % ) 5378.45
Total Prop. Coverage Area ( 27.46 % ) 5621.58
Balance coverage area ( 22.54 % ) 4612.71
FAR CHECK
Perm. FAR Area ( 2.250 ) 46054.33
Total Perm. FAR area 46054.33
Special FAR 729.38
Proposed FAR Area 729.38
Existing Building FAR Area 13239.00
Total Proposed FAR Area 13968.38
Consumed FAR (Factor) 0.68
Balance FAR Area 32085.95
BUA CHECK
Proposed BuiltUp Area 729.39
Existing Building BUA Area 13239.00
Total Proposed BuiltUp Area 13968.39


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 400 meter and upto 500 meter -
Existing Road Width 18 18.00
Proposed Road Width as per Master Plan 18 -
Road Widening Width 0 -
Plot size (as per measurement) 20468.59 20468.59
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High school, Residential school category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Width The minimum size of plot for High school, Residential school category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Plot Depth The minimum size of plot for High school, Residential school category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
Access Width The minimum width of abutting road for High school, Residential school category shall be 12.20 mt. {As per Rule No. 35.1, Table 7}
Plot Frontage The minimum size of plot for High school, Residential school category shall be 6000.0 sq.mt. {As per Rule No. 35.1, Table 7}
FAR Area (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Consumed FAR (1) For Educational, Institutional and Assembly building above 1000 sq.mt. Plot area, the Floor Area Ratio-FAR shall be 2.25 {As per Rule No. 39.3}
(2) No Rule Define.
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Educational Building, Margin required in Front shall be 9.0 mt., Rear 6.0 mt. and 6.0 mt. shall be provided on both side. {As per Rule No. 38.2.1}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
(2) For Educational Bulding, The height of all rooms shall not be less than 3.3 m measured from the surface of the floor to the lowest point of the ceiling
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)