No Image Found   

Failed List Report

Jamshedpur NAC

Version Number: 1.0.62  
Version Date: 16/10/2020 
Report Generated On: 02-08-2022 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0083/W3/2022
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentAddition or Alteration
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBisthupur
Taluka16
Layout Sanction Date31/5/2017
Architect Details
Architect NameSUDIPTO MUKHERJEE
License No.JNAC/ENG/0013/2019
Architect AddressHo. No. 1A, CLASSIC APARTMENT, NEW BARADWARI, P.O. SAKCHI, JAMSHEDPUR, EAST SINGHBHUM
Architect EmailIDsudipto_mukherg@yahoo.co.in
Architect Mobile No9431348519
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot NoHO. NO. NIL, CONTRACTORS AREA
North -
South -
East -
West -
Owner's Details
NameSri SURAJIT KUMAR SARKAR AND OTHERS
AddressHo. No. NIL, CONTRACTORS AREA, BISTUPUR, JAMSHEDPUR
Email IDman27jsr@gmail.com
Mobile No9304117685
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1645.22
2 Plot area as per Document by Applicant 1645.22
3 Physical area measured at site 1645.22
4 Area as per Site Visit (Site Visit Report) 1645.22
5Area as per Drawing 1645.14

Area of Plot Considered : 1645.14

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseResi+Comm
Lower Plot Use
Lower Plot Sub Use
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 1645.14
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1645.14
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 1464.94
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 180.21
180.21
Balance Plot Area 1464.94

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 822.57
Proposed Coverage Area ( 43.46 % ) 715.05
Total Prop. Coverage Area ( 43.46 % ) 715.05
Balance coverage area ( 6.54 % ) 107.52
FAR CHECK
Perm. FAR Area ( 2.50 ) 4112.85
Total Perm. FAR area 4112.85
Residential FAR 3470.93
Commercial FAR 603.01
Proposed FAR Area 4100.35
Total Proposed FAR Area 4100.35
Consumed FAR (Factor) 2.49
Balance FAR Area 12.50
BUA CHECK
Total Proposed BuiltUp Area 6508.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 400 meter and upto 500 meter -
Existing Road Width 11.5 11.50
Proposed Road Width as per Master Plan 11.5 -
Road Widening Width 0 -
Plot size (as per measurement) 1645.22 1645.14
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
DriveWay Rule (1) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 4.25 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For Plor area upto 2000 sq.mt., the minimum width or driveways should not be less than 3.60 mt. {As per Rule No. 41.2 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Margin Rule For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
PWork to PWork Margin Reqd Building to Building margin shall be 6 mt. or 1.5 times side setback required for the taller block whichever is high {As per Rule No. 38.1}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 2 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
VShaft For Building upto 18.0 mt. Ht.,Size of Ventilation shaft shall be 4.0 sq.mt. with mini 1.5 mt. width {As per clause-8.2.5(b), Part-3 of National Building Code of India}
Balcony Projected balcony may be allowed with a width of 1.2 mt. where the setback is more than 4.5 mt. and 4.5 mt. respectively clear driveway is available for the Fire tender movement {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, above G+4 floors or if the number of flats is 16 or more, Mini. 1 Lift shall be required For every 16 flats or part thereof. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) For parking spaces in basements and upper storey of parking floors, if car parking is more then 40 two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved and 5.4m width if one ramp is required shall be provided
(2) -
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.0 M. DEPTH
(5) No need to check distance from Building ENT.GATE
(6) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(7) No need to check distance from Building GUARD ROOM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)