General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0012/W4/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageBisthupur
Taluka16
Architect Details
Architect NameAmarjeet Balmuchu
License No.JNAC/ARC/0008/2018
Architect Address2E, Elllora Apartment, Chandra Jyoti Nagar, Sonari
Architect EmailIDabalmuchu@gmail.com
Architect Mobile No7544000809
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot NoH.NO. 8A
North -
SouthRoad Width - 12.0 MTR WIDE MAIN ROAD
East -
West -
Owner's Details
NameSRI GURVINDER SINGH
AddressHOLDING NO:-8A, RAMDAS BHATTA, WEST AREA BISTUPUR, JAMSHEDPUR
Email IDbmanpreet86@gmail.com
Mobile No9199104106
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 74.27
2 Plot area as per Document by Applicant 74.27
3 Physical area measured at site 74.27
4 Area as per Site Visit (Site Visit Report) 74.27
5Area as per Drawing 74.15

Area of Plot Considered : 74.15

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 74.15
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 74.15
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 60.47
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 13.68
13.68
Balance Plot Area 60.47

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 51.90
Proposed Coverage Area ( 59.02 % ) 43.76
Total Prop. Coverage Area ( 59.02 % ) 43.76
Balance coverage area ( 10.98 % ) 8.14
FAR CHECK
Perm. FAR Area ( 2.500 ) 185.38
Total Perm. FAR area 185.38
Residential FAR 87.52
Proposed FAR Area 96.69
Total Proposed FAR Area 96.69
Consumed FAR (Factor) 1.30
Balance FAR Area 88.69
BUA CHECK
Total Proposed BuiltUp Area 131.28


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 74.27 74.15
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 3.71 13.68 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 13.68 0.00 0.00 - 2.49 - 89.91 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 7 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (SRI GURVINDER SINGH) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (SRI GURVINDER SINGH) 20.00 9.00 9.00 9.00 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI GURVINDER SINGH) Second Floor 2.75 - 3.00 2.75 - 2.91 2.40 - 2.81 OK
First Floor 2.75 - 3.00 2.75 - 2.91 2.40 - 2.81 OK
Ground Floor 2.75 - 3.00 2.75 - 2.91 2.40 - 2.81 OK
Plinth 0.45 - 0.54 - - 0.54 - - 0.54 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (SRI GURVINDER SINGH) Terrace Floor - - 1.02 - - 0.93 - - 0.93 OK
   
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (SRI GURVINDER SINGH) G + 6 3 - 1 OK

 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
51.90 43.76 OK
70% 59.02%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (SRI GURVINDER SINGH) - 43.76
  Total Prop. Coverage Area - 43.76
  Total Coverage Area 51.90 43.76

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (SRI GURVINDER SINGH) 1 131.28 34.59 87.52 9.17 96.69 96.69 01
Grand Total : 1 131.28 34.59 87.52 9.17 96.69 96.69 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (SRI GURVINDER SINGH)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 43.76 9.17 43.76 9.17
First Floor 43.76 43.76 43.76 43.76
Second Floor 43.76 43.76 43.76 43.76
Terrace Floor 0.00 0.00 0.00 0.00
Total : 131.28 96.69 131.28 96.69


[-] UnitBUA Table for Building :A (SRI GURVINDER SINGH)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT 56.09 55.77 3 1
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 3 0
Total: - - 56.09 55.77 6 1


[-] Building :A (SRI GURVINDER SINGH)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 43.76 34.59 0.00 9.17 9.17 9.17 00
First Floor 43.76 0.00 43.76 0.00 43.76 43.76 01
Second Floor 43.76 0.00 43.76 0.00 43.76 43.76 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 131.28 34.59 87.52 9.17 96.69 96.69 01
Total Number of Same Buildings : 1
Total : 131.28 34.59 87.52 9.17 96.69 96.69 01
[-] Table 4c-2

  FAR Area
Building FAR Area:96.69
Existing FAR Area :0.00
Perm.
185.38
Prop.
96.69
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (SRI GURVINDER SINGH) 12.0 MTR WIDE MAINROAD 2.00 2.00 1.50 1.50 0.90 1.04 - 0.01 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (SRI GURVINDER SINGH)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (SRI GURVINDER SINGH)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 0.996 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 0.996 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 0.996 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 0.996 - 0.250 - 0.000 - 0 - - 2.800 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
0.75 mt. long 0.15 mt. High 2.68 mt. Wide Natural Slope - 0.75 - 0.15 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (SRI GURVINDER SINGH) GROUND FLOOR PLAN - 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
SewageTreatmentPlant - - 1.08 - - 0.99 - - 1.09 - - 0.00 OK
RAIN WATERHARVESTING - - 0.73 - - 0.74 - - 0.98 - - 0.00 OK
ENT.GATE - - 0.93 - - 0.36 - - 2.60 - - 0.00 OK
SOLARHEATING SYSTEM - - 0.71 - - 0.74 - - 0.96 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (SRI GURVINDER SINGH) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (SRI GURVINDER SINGH)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 74.15 OK
  Plot Width - 6.08 OK
  Plot Depth - 12.20 OK
  Access Width - 12.00 OK
  Plot Frontage - 6.08 OK
  Coverage Area 51.90 43.76 OK
  FAR Area
Bldg. FAR Area : 96.69
Sanctioned FAR Area :0.00
185.38 96.69 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. -
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SewageTreatmentPlant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATERHARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLARHEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Bed Room3.28x2.96 The area of habitable room shall not be less than 9.5 m2, where there is only one room with a minimum width of 2.4 m. Where there are two rooms, one of these shall not be less than 9.5 m2 and the other not less than 7.5 m2, with a minimum width of 2.1 mt.
Hall4.59x3.04 No Rule Defined
Hall4.59x4.20 No Rule Defined
Kitchen3.28x1.80 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}
Toilet1.20x2.96 Area for Toilet shall be Mini. 2.8 sq.mt. having side mini. 1.2 mt. {Rule No. 42.4.2}