-
No Image Found   

Check List Report

Jamshedpur NAC

Version Number: 1.0.73  
Version Date: 16/10/2020 
Report Generated On: 30-09-2024 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityJAMSHEDPUR NAC
Inward_NoJNAC/BP/0097/W3/2024
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageKADMA
Taluka16
Architect Details
Architect NameNIKHIL SHUKLA
License No.JNAC/ARC/0015/2019
Architect AddressHOUSE NO- 125, CHANAKYAPURI, OLD PURULIA ROAD, JESU BHAWAN, MANGO, JAMSHEDPUR
Architect EmailIDnikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No2681
North -
South -
East -
West -
Owner's Details
NameNOORUZZAMAN, SHABNAM PERWEEN, SHAMSHER ALI, NIKHAT PERWEEN, FARHAT PERWEEN, ARSHAD ALI, GHAZALA PERWEEN, SAIF ALI, AKHTARUZZAMAN, MAHMOODUZZAMAN, WAHIDUZZAMAN, FAHMIDA PERWEEN, KHALIQUZZAMAN, RAISUZZAMAN, LAIQUZZAMAN
AddressRANIKUDAR EXTENSION AREA, JAMSHEDPUR
Email IDnikhil.archi@gmail.com
Mobile No7903331315
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 80.03
2 Plot area as per Document by Applicant 80.03
3 Physical area measured at site 80.03
4 Area as per Site Visit (Site Visit Report) 80.03
5Area as per Drawing 80.03

Area of Plot Considered : 80.03

[-] Table 2b
Proposal Detail :
Unit
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 80.03
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 80.03
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 69.78
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 10.24
10.24
Balance Plot Area 69.78

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 56.02
Proposed Coverage Area ( 54.80 % ) 43.85
Total Prop. Coverage Area ( 54.8 % ) 43.85
Balance coverage area ( 15.21 % ) 12.17
FAR CHECK
Perm. FAR Area ( 2.500 ) 200.07
Total Perm. FAR area 200.07
Residential FAR 100.11
Proposed FAR Area 100.11
Total Proposed FAR Area 100.11
Consumed FAR (Factor) 1.25
Balance FAR Area 99.96
BUA CHECK
Total Proposed BuiltUp Area 131.55


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 80.03 80.03
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 80.03 OK
Plot Width Mt. - - 6.40 OK
Plot Depth Mt. - - 12.50 OK
Access Width Mt. - - 12.00 OK
Plot Frontage Mt. - - 6.40 OK
Coverage Area Sq.Mt. - 56.02 43.85 OK
FAR Area Sq.Mt. - 200.07 100.11 OK
Consumed FAR Sq.Mt. - 2.50 1.25 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 4.00 10.24 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 10.24 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.49 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 2 8 OK
A-1 (NOORUZZAMAN AND OTHERS) Front Margin... 12.00 mt. Wide MainRoad Mt. 2.00 - 2.31 OK
Rear Margin Mt. 1.50 - 1.50 OK
Side1 Margin Mt. 0.90 - 1.36 OK
Side2 Margin Mt. - - 0.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (NOORUZZAMAN AND OTHERS) Height Mt. 20.31 9.00 OK
A (NOORUZZAMAN AND OTHERS) Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.89 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.89 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.89 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
A (NOORUZZAMAN AND OTHERS) Terrace Floor - Height Mt. - - 1.00 OK
Terrace Floor - Clear Height Mt. - - 1.00 OK
Terrace Floor - Beam Clear Height Mt. - - 1.00 OK
A (NOORUZZAMAN AND OTHERS) No. of Floors No. G + 6 3 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.000 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.000 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.500 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 1.38 OK
Width Mt. - - 0.96 OK
Depth Mt. - - 1.45 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.54 OK
Width Mt. - - 0.12 OK
Depth Mt. - - 4.70 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.74 OK
Width Mt. - - 0.79 OK
Depth Mt. - - 2.19 OK
Height Mt. - - - OK
A (NOORUZZAMAN AND OTHERS) Rain Water Harvesting - No No. 1 - 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For JAMSHEDPUR NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height (1) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(2) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
(3) Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)
Kitchen3.28x1.80 Area for Kitchen shall be Mini. 5.0 sq.mt. having side mini. 1.8 mt. {Rule No. 42.3.2}