-
No Image Found

Failed List Report

Mango NAC

Version Number: 1.0.25
Version Date: 12/04/2018
Report Generated On: 23-04-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0022/W09/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameABHISHEK TEWARI
License No.MNAC/ARC/0012/2017
Architect AddressPRATIKSHA 23 FORTUNE CITY NEAR NIT ADITYAPUR 2 JAMSHEDPUR
Architect EmailIDabhitewari1984@gmail.com
Architect Mobile No8603677734
Plot Details
Plot Use Residential
Plot SubUse Boarding
PlotNearbyReligiousStructure NA
Plot/SubPlot No1061
North -
South -
East -
West -
Owner's Details
NameMRS. MENKA SINGH
AddressPLOT NO.- 1061, KHATA NO.-375, WARD NO.- 9, PARDIH MANGO
Email IDABHITEWARI1984@GMAIL.COM
Mobile No8863013769
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 180.63
2 Plot area as per Document by Applicant 180.63
3 Physical area measured at site 180.63
4 Area as per Site Visit (Site Visit Report) 180.63
5Area as per Drawing 180.63

Area of Plot Considered : 180.63

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Boarding
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 180.63
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 180.63
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 126.09
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 54.54
54.54
Balance Plot Area 126.09

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 126.44
Proposed Coverage Area ( 68.90 % ) 124.46
Total Prop. Coverage Area ( 68.9 % ) 124.46
Balance coverage area ( 1.10 % ) 1.98
FAR CHECK
Perm. FAR Area ( 2.50 ) 451.58
Total Perm. FAR area 451.58
Residential FAR 235.79
Proposed FAR Area 246.58
Total Proposed FAR Area 246.58
Consumed FAR (Factor) 1.37
Balance FAR Area 205.00
BUA CHECK
Total Proposed BuiltUp Area 360.26


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 6.8 6.80
Proposed Road Width as per Master Plan 6.8 -
Road Widening Width 0.1 -
Plot size (as per measurement) 180.63 180.63





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) ; In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
(3) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(4) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 21-27 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building Fire Hydrants
(7) -
(8) No need to check distance from Building Overhead WaterTank
(9) No need to check distance from Building ENT.GATE
(10) -
(11) No need to check distance from Building Under ground water tank
(12) -
(13) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)