No Image Found

Check List Report

Mango NAC

Version Number: 1.0.17
Version Date: 16/10/2017
Report Generated On: 08-11-2017

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0010/W09/2017
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageDimna
Taluka16
Architect Details
Architect NameMUKESH KUMAR
License No.MNAC/ENG/0002/2017
Architect AddressBistupur Jamshedpur
Architect EmailIDsrishtidesigner@rediffmail.com
Architect Mobile No9934333171
Plot Details
Plot Use Residential
Plot SubUse Boarding
PlotNearbyReligiousStructure NA
Plot/SubPlot No1917,1918
NorthRoad Width - 6.10
SouthPlot No. - AMAR CHOUDHARY, 1942,1939
EastPlot No. - AMAR CHOUDHARY, 1919,1930
WestPlot No. - DHIREN CHOUDHARY, 1915,1916
Owner's Details
NameSri. RAJENDRA PRASAD
AddressGURUDWARA ROAD, MANGO, P.O & P.S. - MANGO, TOWN - JAMSHEDPUR, DIST.- EAST SINGHBHUM
Email IDshivatransport242@gmail.com
Mobile No9939678901
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 802.97
2 Plot area as per Document by Applicant 802.51
3 Physical area measured at site 802.97
4 Area as per Site Visit (Site Visit Report) 802.51
5Area as per Drawing 802.51

Area of Plot Considered : 802.51

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Boarding
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 802.51
Deduction from Gross Plot area
- Surrender Free of Cost 12.16
12.16
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 790.35
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 708.88
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 12.16
- Common Plot 81.47
93.63
Balance Plot Area 708.88

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 474.21
Proposed Coverage Area ( 48.86 % ) 386.18
Total Prop. Coverage Area ( 48.86 % ) 386.18
Balance coverage area ( 11.14 % ) 88.03
FAR CHECK
Perm. FAR Area ( 2.50 ) 2006.26
Total Perm. FAR area 2006.26
Residential FAR 1543.72
Proposed FAR Area 1555.76
Total Proposed FAR Area 1555.76
Consumed FAR (Factor) 1.94
Balance FAR Area 450.50
BUA CHECK
Total Proposed BuiltUp Area 1946.20


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 6.3 6.30
Proposed Road Width as per Master Plan 6.3 -
Road Widening Width 0.001 -
Plot size (as per measurement) 802.51 802.51


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 790.35 OK
Plot Width Sq.Mt. - - 19.78 OK
Plot Depth Sq.Mt. - - 39.96 OK
Access Width Sq.Mt. 6.10 - 6.30 OK
Plot Frontage Sq.Mt. - - 20.26 OK
Coverage Area Sq.Mt. - 474.21 386.18 OK
FAR Area Sq.Mt. - 2006.26 1555.76 OK
Consumed FAR Sq.Mt. - 2.50 1.94 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 39.52 81.47 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 81.47 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 4.28 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
Car In Area Sq.Mt. 200.00 - 200.00 OK
Visitor's Car Parking In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. 32.00 - 32.00 OK
Other Parking In Area Sq.Mt. - - 157.07 OK
A-1 (BUILDIG) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 5.00 - 5.90 OK
Rear Margin Mt. 4.50 - 4.88 OK
Side1 Margin Mt. 2.00 - 2.01 OK
Side2 Margin Mt. 2.00 - 2.00 OK
A-1 (BUILDIG) BldgLine for 6.30M WIDE ROAD Mt. 0.60 6.50 OK
A-1 (BUILDIG) ResvRoad Width Check for... 6.30M WIDE ROAD Mt. 0.60 0.60 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDIG) Height Mt. 15.95 14.15 OK
A (BUILDIG) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Height Mt. 2.75 - 2.75 OK
Plinth - Height Mt. - - 0.15 OK
A (BUILDIG) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A (BUILDIG) No. of Floors No. P + 4 5 OK
No. of Tenements No. - 16 OK
A (BUILDIG) TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Passage Name - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Width Mt. 1.00 2.44 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Length Mt. - 4.76 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Passage Name - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Width Mt. 1.00 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Length Mt. - 6.97 OK
A (BUILDIG) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.153 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.142 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.219 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.591 OK
Toilet Area Sq.Mt. - 5.00 4.57 OK
Width Mt. - - 2.14 OK
Depth Mt. - - 2.14 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.42 OK
Width Mt. - - 1.79 OK
Depth Mt. - - 1.91 OK
Height Mt. - - - OK
SUMP TANK Area Sq.Mt. - - 3.17 OK
Width Mt. - - 1.33 OK
Depth Mt. - - 2.38 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 2.35 OK
Width Mt. - - 1.73 OK
Depth Mt. - - 1.73 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.35 OK
Width Mt. - - 0.12 OK
Depth Mt. - - 3.05 OK
Height Mt. - - - OK
A (BUILDIG) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
A (BUILDIG) TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.52 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.22 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.56 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.22 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.56 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.52 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.22 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.56 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.52 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.83 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.84 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.22 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.56 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Width Mt. 0.75 0.46 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Depth Mt. - 1.52 OK
TYPICAL - 1, 2, 3& 4 FLOOR PLAN - CHHAJJA - Area Sq.Mt. - 0.70 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 15-21 mt., Margin required in Front shall be 5.0 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only Stilt + 4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)