No Image Found

Failed List Report

Mango NAC

Version Number: 1.0.28
Version Date: 30/06/2018
Report Generated On: 13-07-2018

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0019/W10/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3528(N), 3532(N)
NorthPlot No. - 3527
SouthPlot No. - 3531
EastPlot No. - 32
WestRoad Width - 5
Owner's Details
NameSri Hiren Hazam
AddressH. No.-43, Teachers Colony, Mango Jamshedpur
Email IDmamonipramanik68@gmail.com
Mobile No8969197005
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 68.68
2 Plot area as per Document by Applicant 68.68
3 Physical area measured at site 68.45
4 Area as per Site Visit (Site Visit Report) 68.68
5Area as per Drawing 68.45

Area of Plot Considered : 68.45

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Semi-Detached House
Gross Plot Area 68.45
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 68.45
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 58.52
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 9.93
9.93
Balance Plot Area 58.52

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 47.91
Proposed Coverage Area ( 57.55 % ) 39.39
Total Prop. Coverage Area ( 57.55 % ) 39.39
Balance coverage area ( 12.45 % ) 8.52
FAR CHECK
Perm. FAR Area ( 1.80 ) 123.21
Total Perm. FAR area 123.21
Residential FAR 39.39
Proposed FAR Area 39.39
Total Proposed FAR Area 39.39
Consumed FAR (Factor) 0.58
Balance FAR Area 83.82
BUA CHECK
Total Proposed BuiltUp Area 39.39


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 5 5.00
Proposed Road Width as per Master Plan 5 -
Road Widening Width 0.01 -
Plot size (as per measurement) 68.68 68.45





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Building Level (Rooms)