No Image Found

Detail Scrutiny Report

Mango NAC

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 06-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority MANGO NAC
Inward_No MNAC/BP/0033/W09/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Mango
Taluka 16
Architect Details
Architect Name Premendra Krishna Mitra
License No. MNAC/ENG/0003/2017
Architect Address 18,Road No 1, New Kashidih East, Sakchi, PO-Sakchi, Kalimali, Jamshedpur
Architect EmailID premendra.pk@gmail.com
Architect Mobile No 9431131897
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 2972
North Plot No. - WAKIL AHMAD
South Road Width - 5.50
East Plot No. - G. RAHMAN
West Plot No. - E. LAKRA
Owner's Details
Name RIZWANA KHATOON AND OTHERS
Address 522, ROAD NO. 6, JAWAHAR NAGAR, P.O. AZAD NAGAR,
Email ID firozakhtar106@gmail.com
Mobile No 8340280376
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 501.80
2 Plot area as per Document by Applicant 501.54
3 Physical area measured at site 501.54
4 Area as per Site Visit (Site Visit Report) 501.54
5 Area as per Drawing 501.54

Area of Plot Considered : 501.54

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Residential Bldg/Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 501.54
Deduction from Gross Plot area
- Road Widening Area 5.96
5.96
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 495.58
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 445.66
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 5.96
- Common Plot 49.92
55.89
Balance Plot Area 445.66

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 297.35
Proposed Coverage Area ( 59.96 % ) 297.17
Total Prop. Coverage Area ( 59.96 % ) 297.17
Balance coverage area ( 0.04 % ) 0.18
FAR CHECK
Perm. FAR Area ( 1.80 ) 892.04
Maximum Permissible FAR Area ( 2.50 ) 1238.95
Total Perm. FAR area 1238.95
Residential FAR 885.02
Proposed FAR Area 899.76
Total Proposed FAR Area 899.76
Consumed FAR (Factor) 1.82
Balance FAR Area 339.19
Total Paid Proposed FAR Area 7.72
BUA CHECK
Total Proposed BuiltUp Area 1194.35


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 5.5 5.50
Proposed Road Width as per Master Plan 5.5 -
Road Widening Width 0.3 0.30
Plot size (as per measurement) 501.54 501.54




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 49.56 49.92 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 49.92 0.00 0.00 - 2.24 - 88.78 ROAD WIDENING AREA OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 4 7 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (B) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (B) 10.00 8.79 8.79 8.79 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (B) Second Floor 2.75 - 2.85 OK
First Floor 2.75 - 2.85 OK
Ground Floor 2.75 - 2.85 OK
Basement Floor 2.40 - 2.60 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (B) Terrace Floor 1.00 1.20 1.07 OK


[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (B) Basement Floor - 1.16 - 302.84 - 2.63 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (B) - 302.84
Total - 302.84 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (B) ROAD WIDENING AREA 3.00 5.14 1.80 2.21 1.00 1.05 1.00 1.01 OK


[-] Permissible Use In Basement
Basement Area Status
Permissible Proposed
27.45 10.34 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (B) G + 2 3 - 12 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (B) 1 1 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
297.35 297.17 OK
60% 59.96%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (B) - 297.17
Total Prop. Coverage Area - 297.17
Total Coverage Area 297.35 297.17


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Accessory Use Parking Resi. Stair
A (B) 1 1221.88 27.53 1194.35 9.75 10.34 274.52 885.01 14.74 899.75 899.75 12
Grand Total : 1 1221.88 27.53 1194.35 9.75 10.34 274.52 885.01 14.74 899.75 899.75 12


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (B)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Maximum Permissible FAR Area (Sq.mt.) Total Paid Built Up Area (Sq.mt.)
Basement Floor 302.84 14.74 302.84 14.74 7.71 158.41
Ground Floor 297.17 297.17 297.17 297.17 0.00 0.00
First Floor 297.17 293.92 297.17 293.92 0.00 0.00
Second Floor 297.17 293.92 297.17 293.92 0.00 0.00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00
Total : 1194.35 899.75 1194.35 899.75 7.71 158.41


[-] UnitBUA Table for Building :A (B) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN 1 FLAT 56.80 52.43 6 4
2 FLAT 56.02 51.63 6
3 FLAT 78.45 73.10 8
4 FLAT 79.21 73.82 8
TYPICAL - 1, 2 FLOOR PLAN 5 FLAT 79.21 73.82 8 8
6 FLAT 78.45 73.10 8
7 FLAT 56.02 51.63 6
8 FLAT 56.80 52.43 6
Total: - - 811.44 752.94 84 12


[-] Building :A (B)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Lift Accessory Use Parking Resi. Stair
Basement Floor 305.47 2.63 302.84 3.25 10.34 274.52 0.00 14.74 14.74 14.74 00
Ground Floor 305.47 8.30 297.17 0.00 0.00 0.00 297.17 0.00 297.17 297.17 04
First Floor 305.47 8.30 297.17 3.25 0.00 0.00 293.92 0.00 293.92 293.92 04
Second Floor 305.47 8.30 297.17 3.25 0.00 0.00 293.92 0.00 293.92 293.92 04
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 1221.88 27.53 1194.35 9.75 10.34 274.52 885.01 14.74 899.75 899.75 12
Total Number of Same Buildings : 1
Total : 1221.88 27.53 1194.35 9.75 10.34 274.52 885.01 14.74 899.75 899.75 12

[-] Table 4c-2

FARArea
Building FAR Area : 899.76
Existing FAR Area : 0.00
Perm.
1238.95
Prop.
899.76
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (B) ROAD WIDENING AREA 3.00 5.14 1.80 2.21 1.00 1.05 1.00 1.01 OK







[-] Inner Building Details (Table 6)


[-] Passage Details

[-] For Building :A (B)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 1.79 mt. Wide Passage 7.35 1.00 1.79 - 4.11 OK
TYPICAL - 1, 2 FLOOR PLAN 1.79 mt. Wide Passage 7.35 1.00 1.79 - 4.11 OK



[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (B) 8.79 - 1 OK

[-] Lift Check Table

[-] For Building :A (B)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
BASEMENT FLOOR PLAN Lift 1.70 1.71 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 2.55 1.90 6.04 OK
GROUND FLOOR PLAN Lift 1.70 1.71 1.90 1.90 OK
TYPICAL - 1, 2 FLOOR PLAN Lift 1.70 1.71 1.90 1.90 OK




[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car Visitors Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (B) Residential Residential Bldg/Apartment > 0 1 12.00 1.00 12 - - - - - - -
> 0 1 12.00 - - - - - - 1 12 -
> 0 1 12.00 - - - 1 2 - - - -
Total : - - - - 12 12 - 2 2 - 12 12

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 12 150.00 OK
Total Car 12 150.00 12 150.00 OK
Visitor's Car Parking 2 25.00 2 25.00 OK
TwoWheeler 12 24.00 12 24.00 OK
Other Parking - - - 140.15 OK
Total 199.00 339.15 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (B)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.372 0.250 0.305 0.200 0.000 - 0 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.372 - 0.305 - 0.000 - 0 - - 2.476 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.372 0.250 0.305 0.200 0.143 - 10 - - 0.000 OK
TYPICAL - 1, 2 FLOOR PLAN STAIRCASE 0.900 1.372 0.250 0.305 0.200 0.143 - 10 - - 0.000 OK



[-] Ramp Checks(Table 8b)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
5.93 mt. long 1.16 mt. High 3.85 mt. Wide Natural Slope - 3.85 - 1.16 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (B) BASEMENT FLOOR PLAN 1 1 OK
TERRACE FLOOR PLAN - 1 OK
GROUND FLOOR PLAN - 1 OK
TYPICAL - 1, 2 FLOOR PLAN - 2 OK


[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (B)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
BASEMENT FLOOR PLAN CHHAJJA 0.75 0.46 - 2.40 - 1.10 OK
TERRACE FLOOR PLAN CHHAJJA 0.75 0.46 - 2.40 - 1.10 OK
GROUND FLOOR PLAN CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 2.72 - 1.25 OK
CHHAJJA 0.75 0.46 - 2.72 - 1.25 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
TYPICAL - 1, 2 FLOOR PLAN CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK
CHHAJJA 0.75 0.46 - 2.72 - 1.25 OK
CHHAJJA 0.75 0.46 - 2.72 - 1.25 OK
CHHAJJA 0.75 0.46 - 1.50 - 0.69 OK
CHHAJJA 0.75 0.46 - 1.80 - 0.83 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 1.72 - - 1.09 - - 1.59 - - 0.00 OK
EFFLUENT TREATMENT PLANT - - 2.76 - - 1.66 - - 1.66 - - 0.00 OK
ENT.GATE - - 0.28 - - 0.07 - - 3.85 - - 0.00 OK
Generator Room - - 10.34 - - 2.06 - - 5.02 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (B) Rain Water Harvesting 1 - 1 OK
Entrance Gate 1 - 1 OK




[-] Floor Details (Table 9)


[-] Building:A (B)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1, 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 495.58 OK
Plot Width - 20.13 OK
Plot Depth - 24.61 OK
Access Width - 5.50 OK
Plot Frontage - 19.87 OK
Coverage Area 297.35 297.17 OK
FARArea
Bldg. FAR Area : 899.76
Sanctioned FAR Area : 0.00
1238.95 899.76 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 4.80 (16 ft.) to 6.10 mt., the Floor Area Ratio-FAR shall be 1.8 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 21-27 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 4.8-6.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 4.8-6.1 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt., for every 16 flats or upto G+4 floors, No Lift is reqd. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
(2) -
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) -
(4) No need to check distance from Building EFFLUENT TREATMENT PLANT
(5) No need to check distance from Building ENT.GATE
(6) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(7) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)