Failed List Report

Mango NAC

Version Number: 1.0.31
Version Date: 30/06/2018
Report Generated On: 03-01-2019

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority MANGO NAC
Inward_No MNAC/BP/0035/W09/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Dimna
Taluka 16
Architect Details
Architect Name RAJESH KUMAR
License No. MNAC/STU/0019/2017
Architect Address SONARI MANBODH MOHALLA H.NO-827B/BLOCK,POST-KAGALNAGAR,PIN-831011
Architect EmailID rajesh.821@rediffmail.com
Architect Mobile No 9102825085
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1233
North Road Width - 18.0 M
South Plot No. - 1235
East Plot No. - 1233(PART)
West Plot No. - 1233(PART)
Owner's Details
Name RANJEET SAH
Address H.NO.- 21/A, RAMNAGAR ROAD NO.6. MANGO
Email ID rajesh.821@rediffmail.com
Mobile No 9234698660
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 334.57
2 Plot area as per Document by Applicant 326.32
3 Physical area measured at site 326.32
4 Area as per Site Visit (Site Visit Report) 326.32
5 Area as per Drawing 325.46

Area of Plot Considered : 325.46

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Commercial
Plot SubUse Shop
Building Structure Non-Highrise
Building Type Single Semi-Detached House
Gross Plot Area 325.46
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 325.46
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 246.28
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 79.19
79.19
Balance Plot Area 246.28

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 162.73
Proposed Coverage Area ( 49.79 % ) 162.06
Total Prop. Coverage Area ( 49.79 % ) 162.06
Balance coverage area ( 0.21 % ) 0.67
FAR CHECK
Perm. FAR Area ( 2.50 ) 813.65
Total Perm. FAR area 813.65
Commercial FAR 486.18
Proposed FAR Area 502.99
Total Proposed FAR Area 502.99
Consumed FAR (Factor) 1.55
Balance FAR Area 310.66
BUA CHECK
Total Proposed BuiltUp Area 648.24


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 18 18.00
Proposed Road Width as per Master Plan 18 -
Road Widening Width 0.9 -
Plot size (as per measurement) 326.32 325.46





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 27-33 mt. and Plot width upto 10 mt., Margin required in Front shall be 6.5 mt., Rear 4.0 mt. and Atleast 1.5 mt. shall be provided at one side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building SUMP TANK
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)