No Image Found

Check List Report

Mango NAC

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 06-11-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority MANGO NAC
Inward_No MNAC/BP/0036/W08/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Mango
Taluka 16
Architect Details
Architect Name Kunal Sinha Mahapatra
License No. MNAC/ENG/0006/2017
Architect Address G/2, D-Block, D-Choudhury Madusudhan complex, Dimna more, Mango, Jamshedpur
Architect EmailID kunal.sinha1977@gmail.com
Architect Mobile No 9903304812
Plot Details
Plot Use Mixed
Plot SubUse Resi+Comm
PlotNearbyReligiousStructure NA
Plot/SubPlot No 883(P)
North Road Width - 7.31
South Plot No. - 884(P)
East Plot No. - 882(P)
West Plot No. - 886(P)
Owner's Details
Name DINESH MENON
Address Duplex No. 62, Vijaya Heritage, 6/7th phase, Kadma, Jamshedpur.
Email ID dinesh.menonjsr@gmail.com
Mobile No 3994611694
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 886.58
2 Plot area as per Document by Applicant 886.58
3 Physical area measured at site 886.58
4 Area as per Site Visit (Site Visit Report) 886.58
5 Area as per Drawing 886.58

Area of Plot Considered : 886.58

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Mixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub Use Resi+Comm
Lower Plot Use
Lower Plot Sub Use
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 886.58
Deduction from Gross Plot area
- Surrender Free of Cost 4.81
4.81
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 881.77
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 789.96
Deductions for Balance Plot Area (from Gross Plot Area)
- Surrender Free of Cost 4.81
- Common Plot 91.81
96.62
Balance Plot Area 789.96

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 529.06
Proposed Coverage Area ( 20.96 % ) 184.78
Total Prop. Coverage Area ( 20.96 % ) 184.78
Balance coverage area ( 39.04 % ) 344.28
FAR CHECK
Perm. FAR Area ( 2.50 ) 2216.45
Total Perm. FAR area 2216.45
Residential FAR 146.82
Commercial FAR 184.78
Proposed FAR Area 331.59
Total Proposed FAR Area 331.59
Consumed FAR (Factor) 0.37
Balance FAR Area 1884.86
BUA CHECK
Total Proposed BuiltUp Area 331.60


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 300 meter and upto 400 meter -
Existing Road Width 7.31 7.31
Proposed Road Width as per Master Plan 7.31 -
Road Widening Width 0 0.30
Plot size (as per measurement) 886.58 886.58


Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 881.77 OK
Plot Width Sq.Mt. - - 22.34 OK
Plot Depth Sq.Mt. - - 39.47 OK
Access Width Sq.Mt. - - 7.31 OK
Plot Frontage Sq.Mt. - - 16.02 OK
Coverage Area Sq.Mt. - 529.06 184.78 OK
FAR Area Sq.Mt. - 2216.45 331.59 OK
Consumed FAR Sq.Mt. - 2.50 0.37 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 88.18 91.81 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 91.81 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.39 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 5 OK
Car In Area Sq.Mt. - - 37.50 OK
Total Car In Area Sq.Mt. 37.50 - 37.50 OK
Visitor's Car Parking In Area Sq.Mt. - - 12.50 OK
TwoWheeler In Area Sq.Mt. 8.00 - 10.00 OK
A-1 (MENONS) Front Margin... ROAD WIDENING AREA(SURRENDERED FREE OF COST) Mt. 4.00 - 4.00 OK
Rear Margin Mt. 4.00 - 15.36 OK
Side1 Margin Mt. 1.50 - 1.50 OK
Side2 Margin Mt. 1.50 - 6.54 OK
A-1 (MENONS) BldgLine for 7.31 M WIDE MAIN ROAD Mt. 0.10 4.30 OK
A-1 (MENONS) ResvRoad Width Check for... 7.31 M WIDE MAIN ROAD Mt. 0.10 0.30 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (MENONS) Height Mt. 15.27 6.60 OK
A (MENONS) First Floor - Height Mt. 2.75 - 3.30 OK
Ground Floor - Height Mt. 2.75 - 3.30 OK
Plinth - Height Mt. 0.45 - 0.45 OK
A (MENONS) Terrace Floor - Height Mt. 1.00 1.20 1.00 OK
A (MENONS) No. of Floors No. G + 4 2 OK
No. of Tenements No. - 1 OK
GROUND FLOOR PLAN Staircase -4FL - Flight Width Mt. 0.750 1.050 OK
Staircase -4FL - Tread Width Mt. 0.225 0.300 OK
Staircase -4FL - Riser Height Mt. 0.200 0.075 OK
Staircase -4FL - Riser No. On Flight No. - 6 OK
Staircase -4FL - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN Staircase -4FL - Flight Width Mt. 0.750 1.050 OK
Staircase -4FL - Tread Width Mt. 0.225 0.300 OK
Staircase -4FL - Riser Height Mt. 0.200 0.075 OK
Staircase -4FL - Riser No. On Flight No. - 6 OK
Staircase -4FL - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN Staircase -4FL - Flight Width Mt. - 1.050 OK
Staircase -4FL - Tread Width Mt. - 0.300 OK
Staircase -4FL - Riser Height Mt. - - OK
Staircase -4FL - Riser No. On Flight No. - - OK
Staircase -4FL - Cabin Ht. Mt. 2.100 - 2.550 OK
RAIN WATER HARVESTING 3.00 DIA & 3.0 M. DEPTH Area Sq.Mt. - - 7.65 OK
Width Mt. - - 3.12 OK
Depth Mt. - - 3.13 OK
Height Mt. - - - OK
A (MENONS) Rain Water Harvesting - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 39-45 mt. and Plot width 21-27 mt., Margin required in Front shall be 4.0 mt., Rear 4.0 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.0 M. DEPTH
Accessory Use Number Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
Building Level (Rooms)