No Image Found

Check List Report

Mango NAC

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 18-07-2019

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0049/W08/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameMOHAMMAD BELAL NASIR
License No.MNAC/ENG/0007/2016
Architect AddressHOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailIDdreamdesign.jsr.bn@gmail.com
Architect Mobile No9835307058
Plot Details
Plot Use Residential
Plot SubUse Residential Bldg/Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No1074 & 1075
North -
South -
East -
West -
Owner's Details
NameMD NOORUL HASSAN
AddressHASSAN MANZIL, ROAD NO. 04, AZADNAGAR, MANGO, JAMSHEDPUR
Email IDdreamdesign.jsr@gmail.com
Mobile No9234441214
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 670.02
2 Plot area as per Document by Applicant 670.02
3 Physical area measured at site 670.02
4 Area as per Site Visit (Site Visit Report) 670.02
5Area as per Drawing 670.02

Area of Plot Considered : 670.02

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Residential Bldg/Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 670.02
Deduction from Gross Plot area
- Road Widening Area 21.40
21.40
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 648.62
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 580.92
Deductions for Balance Plot Area (from Gross Plot Area)
- Road Widening Area 21.40
- Common Plot 67.70
89.10
Balance Plot Area 580.92

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 389.17
Proposed Coverage Area ( 59.91 % ) 388.62
Total Prop. Coverage Area ( 59.91 % ) 388.62
Balance coverage area ( 0.08 % ) 0.55
FAR CHECK
Perm. FAR Area ( 2.50 ) 1621.55
Total Perm. FAR area 1621.55
Residential FAR 1307.40
Proposed FAR Area 1323.75
Total Proposed FAR Area 1323.75
Consumed FAR (Factor) 2.04
Balance FAR Area 297.80
BUA CHECK
Total Proposed BuiltUp Area 1745.43


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 400 meter and upto 500 meter -
Existing Road Width 6.2 6.20
Proposed Road Width as per Master Plan 6.2 -
Road Widening Width 0 0.65
Plot size (as per measurement) 670.02 670.02
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 648.62 OK
Plot Width Mt. - - 32.89 OK
Plot Depth Mt. - - 19.72 OK
Access Width Mt. - - 6.20 OK
Plot Frontage Mt. - - 32.92 OK
Coverage Area Sq.Mt. - 389.17 388.62 OK
FAR Area Sq.Mt. - 1621.55 1323.75 OK
Consumed FAR Sq.Mt. - 2.50 2.04 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 64.86 67.70 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 67.70 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.53 OK
Tree Cover (Plantation) - Angle Degree - 90.00 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
Car In Area Sq.Mt. - - 176.32 OK
Total Car In Area Sq.Mt. 175.00 - 176.32 OK
Visitor's Car Parking In Area Sq.Mt. - - 25.00 OK
Total Visitor Parking In Area Sq.Mt. 25.00 - 25.00 OK
TwoWheeler In Area Sq.Mt. - - 29.96 OK
Total TwoWheeler In Area Sq.Mt. 28.00 - 29.96 OK
Other Parking In Area Sq.Mt. - - 141.00 OK
A-1(MD NOORUL HASSAN) Front Margin... ROAD WIDENING AREA Mt. 3.00 - 3.01 OK
Rear Margin Mt. 1.80 - 1.82 OK
Side1 Margin Mt. 2.50 - 2.69 OK
Side2 Margin Mt. 2.50 - 2.74 OK
A-1(MD NOORUL HASSAN) BldgLine for 6.2 M MAINROAD Access Road Mt. 0.65 3.66 OK
A-1(MD NOORUL HASSAN) ResvRoad Width Check for... 6.2 M MAINROAD Access Road Mt. 0.65 0.65 OK

Building Related Details
Name Description Unit Reqd Perm Proposed Status
A(MD NOORUL HASSAN) Height Mt. 12.96 12.00 OK
A(MD NOORUL HASSAN) Third Floor - Height Mt. 2.60 - 3.00 OK
Third Floor - Clear Height Mt. 2.60 - 2.87 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.62 OK
Second Floor - Height Mt. 2.60 - 3.00 OK
Second Floor - Clear Height Mt. 2.60 - 2.87 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.62 OK
First Floor - Height Mt. 2.60 - 3.00 OK
First Floor - Clear Height Mt. 2.60 - 2.87 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.62 OK
Ground Floor - Height Mt. 2.60 - 3.00 OK
Ground Floor - Clear Height Mt. 2.60 - 2.87 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.62 OK
Plinth - Height Mt. 0.45 - 0.45 OK
Plinth - Clear Height Mt. - - 0.45 OK
Plinth - Beam Clear Height Mt. - - 0.45 OK
A(MD NOORUL HASSAN) Terrace Floor - Height Mt. 1.00 1.20 1.07 OK
A(MD NOORUL HASSAN) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 14 OK
A(MD NOORUL HASSAN) Number Of Lift(s) No. 1 1 OK
A(MD NOORUL HASSAN) FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL -2 & 3 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL -2 & 3 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.260 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL -2 & 3 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.260 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.260 OK
STAIRCASE - Tread Width Mt. 0.250 0.254 OK
STAIRCASE - Riser Height Mt. 0.200 0.143 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.260 OK
STAIRCASE - Tread Width Mt. - 0.254 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.470 OK
Sewage Treatment Plant Area Sq.Mt. - - 0.87 OK
Width Mt. - - 0.75 OK
Depth Mt. - - 1.18 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.58 OK
Width Mt. - - 2.41 OK
Depth Mt. - - 2.42 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.02 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 4.47 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 1.62 OK
Width Mt. - - 0.90 OK
Depth Mt. - - 1.80 OK
Height Mt. - - - OK
A(MD NOORUL HASSAN) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 15-21 mt. and Plot width 27-33 mt., Margin required in Front shall be 3.0 mt., Rear 1.8 mt. and 2.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Line Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
ResvRoad Width Check The min. width of Road for length of Road Exceeding 300 mt. shall be 7.50 mt. {As per Rule No. 34 Table No. 6}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(5) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height 12.0 mt. or above, upto G+4 floors or if the number of flats is upto 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)