No Image Found

Detail Scrutiny Report

Mango NAC

Version Number: 1.0.36
Version Date: 29/04/2019
Report Generated On: 14-06-2019
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0050/W08/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No803 a
NorthRoad Width - 12
SouthSurvey No. - Road
EastSurvey No. - Md. Quasim
WestSurvey No. - Govind Gorai
Owner's Details
NameRehan Usmani & Ramiz Usman
AddressPardih Mango
Email IDprince.enterprises2005@gmail.com
Mobile No8092551450
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 167.47
2 Plot area as per Document by Applicant 167.25
3 Physical area measured at site 167.25
4 Area as per Site Visit (Site Visit Report) 167.25
5Area as per Drawing 167.16

Area of Plot Considered : 167.16

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 167.16
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 167.16
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 158.48
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 8.68
8.68
Balance Plot Area 158.48

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 117.01
Proposed Coverage Area ( 69.66 % ) 116.44
Total Prop. Coverage Area ( 69.66 % ) 116.44
Balance coverage area ( 0.34 % ) 0.57
FAR CHECK
Perm. FAR Area ( 2.50 ) 417.90
Total Perm. FAR area 417.90
Residential FAR 307.37
Proposed FAR Area 319.59
Total Proposed FAR Area 319.59
Consumed FAR (Factor) 1.91
Balance FAR Area 98.31
BUA CHECK
Total Proposed BuiltUp Area 349.38


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 12 12.00
Proposed Road Width as per Master Plan 12 -
Road Widening Width 0 -
Plot size (as per measurement) 167.25 167.16
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 8.36 8.68 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 8.68 0.00 0.00 - 0.96 - 87.56 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 3 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (REHAN USMANI AND RAMIZ USMANI) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (REHAN USMANI AND RAMIZ USMANI) 20.59 9.00 9.00 9.00 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (REHAN USMANI AND RAMIZ USMANI) Second Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
Ground Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.70 OK
Plinth 0.45 - 0.45 - - 0.45 - - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (REHAN USMANI AND RAMIZ USMANI) Terrace Floor 1.00 1.20 1.10 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (REHAN USMANI AND RAMIZ USMANI) G + 6 3 - 1 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
117.01 116.44 OK
70% 69.66%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (REHAN USMANI AND RAMIZ USMANI) - 116.44
Total Prop. Coverage Area - 116.44
Total Coverage Area 117.01 116.44

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (REHAN USMANI AND RAMIZ USMANI) 1 349.38 29.78 307.37 12.23 319.60 319.60 01
Grand Total : 1 349.38 29.78 307.37 12.23 319.60 319.60 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (REHAN USMANI AND RAMIZ USMANI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 116.44 86.66 116.44 86.66
First Floor 116.47 116.47 116.47 116.47
Second Floor 116.47 116.47 116.47 116.47
Terrace Floor 0.00 0.00 0.00 0.00
Total : 349.38 319.60 349.38 319.60


[-] UnitBUA Table for Building :A (REHAN USMANI AND RAMIZ USMANI)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT UNIT 1 FLAT 307.37 265.02 9 1
TYPICAL - 1& 2 FLOOR PLAN SPLIT UNIT 1 FLAT 0.00 0.00 13 0
Total: - - 307.37 265.02 35 1


[-] Building :A (REHAN USMANI AND RAMIZ USMANI)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 116.44 29.78 74.43 12.23 86.66 86.66 01
First Floor 116.47 0.00 116.47 0.00 116.47 116.47 00
Second Floor 116.47 0.00 116.47 0.00 116.47 116.47 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 349.38 29.78 307.37 12.23 319.60 319.60 01
Total Number of Same Buildings : 1
Total : 349.38 29.78 307.37 12.23 319.60 319.60 01
[-] Table 4c-2

FARArea
Building FAR Area:319.59
Existing FAR Area :0.00
Perm.
417.90
Prop.
319.59
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (REHAN USMANI AND RAMIZ USMANI) 12M WIDE ROAD 2.50 2.59 1.50 1.55 - 0.00 0.90 0.91 OK






[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.


[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (REHAN USMANI AND RAMIZ USMANI)


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (REHAN USMANI AND RAMIZ USMANI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
TERRACE FLOOR PLAN STAIRCASE OVERHEAD - 1.200 - 0.250 - 0.000 - 0 - - 2.400 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK
TYPICAL - 1& 2 FLOOR PLAN STAIRCASE 0.900 1.200 0.250 0.250 0.200 0.150 - 10 - - 0.000 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
RAIN WATER HARVESTING - - 7.73 - - 1.96 - - 3.94 - - 0.00 OK
ENT.GATE - - 0.34 - - 0.15 - - 2.36 - - 0.00 OK




[-] Floor Details (Table 9)


[-] Building:A (REHAN USMANI AND RAMIZ USMANI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.




[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 167.16 OK
Plot Width - 9.15 OK
Plot Depth - 18.28 OK
Access Width - 12.00 OK
Plot Frontage - 9.15 OK
Coverage Area 117.01 116.44 OK
FARArea
Bldg. FAR Area : 319.59
Sanctioned FAR Area :0.00
417.90 319.59 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) No Rule Defined
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
Building Level (Rooms)