RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0052/W09/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameMUKESH KUMAR
License No.MNAC/ENG/0002/2017
Architect AddressBistupur Jamshedpur
Architect EmailIDsrishtidesigner@rediffmail.com
Architect Mobile No9934333171
Plot Details
Plot Use Residential
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No1595
NorthCTS No. - CHARAN MAJHI
SouthCTS No. - SMT. S. HEMBROM
EastCTS No. - BADAL MAJHI AND ROAD
WestCTS No. - SAGAR MAJHI
Owner's Details
NameALOK KUMAR HEMBROM
AddressKUMRUM BASTI , N.H. 33 , MANGO , JAMSHEDPUR
Email IDsavioanthony123@gmail.com
Mobile No8092024320
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 866.14
2 Plot area as per Document by Applicant 856.79
3 Physical area measured at site 856.79
4 Area as per Site Visit (Site Visit Report) 856.79
5Area as per Drawing 865.79

Area of Plot Considered : 856.79

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse ResiComm Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 856.79
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 856.79
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 765.55
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 91.24
91.24
Balance Plot Area 765.55

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 514.07
Proposed Coverage Area ( 56.28 % ) 482.23
Total Prop. Coverage Area ( 56.28 % ) 482.23
Balance coverage area ( 3.72 % ) 31.84
FAR CHECK
Perm. FAR Area ( 1.50 ) 1285.18
Maximum Permissible FAR Area ( 2.50 ) 2141.97
Total Perm. FAR area 2141.97
Residential FAR 984.70
Commercial FAR 482.23
Proposed FAR Area 1483.53
Total Proposed FAR Area 1483.53
Consumed FAR (Factor) 1.73
Balance FAR Area 658.44
Total Paid Proposed FAR Area 198.35
BUA CHECK
Total Proposed BuiltUp Area 2000.62


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 4.57 -
Road Widening Width 0.2 -
Plot size (as per measurement) 856.79 865.79
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
Total Visitor Parking In Area Sq.Mt. 25.00 - 13.50 Failed
Total TwoWheeler In Area Sq.Mt. 74.00 - 56.00 Failed

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (BUILDING) TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. - 1.20 Failed
TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. - 1.20 Failed
TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. - 1.20 Failed
TYPICAL - 1& 2 FLOOR PLAN - BALCONY - Width Mt. - 1.21 Failed
   
   

[-] Building:A (BUILDING)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 1& 2 FLOOR PLAN

[-] Misc Checks (Table 9a)
Tnmt No. Room Name Area Width Depth Ventilation Status
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
SPLIT FLAT-8 TOILET 1.41X1.90 2.80 2.68 1.20 1.41 1.20 1.90 0.30 0.37 Failed
SPLIT FLAT-5 TOILET 2.16X1.22 2.80 2.64 1.20 1.22 1.20 2.16 0.30 0.37 Failed


   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
(3) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 27-33 mt. and Plot width 27-33 mt., Margin required in Front shall be 4.0 mt., Rear 2.5 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
Balcony (1) No projected balcony shall be allowed, on setback less than 2.0 mt. {As per Rule No. 46.4}
(2) Projected balcony may be allowed on first floor subject to condition that the side and rear setback of the Building is more than 4.5 mt. and 4.5m. clear driveway is available for Fire movement. {As per Rule No. 46.4 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 12.0 mt. or upto G+4 floors, if the number of flats is more than 16, provision of lift will be compulsory. {As per Rule No. 49.1.2}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; Number of riser shall not exceed 14 per flight of stairs. {As per Rule No. 43.5.2.6}
(5) No Rule Defined
(6) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building SUMP TANK
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)