-
No Image Found

Detail Scrutiny Report

Mango NAC

Version Number: 1.0.30
Version Date: 30/06/2018
Report Generated On: 14-12-2018

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority MANGO NAC
Inward_No MNAC/BP/0043/W10/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Mango
Taluka 16
Architect Details
Architect Name NIKHIL SHUKLA
License No. MNAC/ARC/0002/2018
Architect Address HOUSE NO- 125, CHANAKYAPURI COLONY, OLD PURULIA ROAD, NEAR JESU MANGO, JAMSHEDPUR
Architect EmailID nikhil.archi@gmail.com
Architect Mobile No 9234459150
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 3697
North -
South -
East -
West -
Owner's Details
Name MR. PAWAN KUMAR CHOUHAN
Address SHANTI NAGAR , SANJY PATH DIMNA ROAD MANGO, JAMSHEDPUR
Email ID nikhil.archi@gmail.com
Mobile No 9304593268
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 133.66
2 Plot area as per Document by Applicant 133.66
3 Physical area measured at site 133.66
4 Area as per Site Visit (Site Visit Report) 133.66
5 Area as per Drawing 133.63

Area of Plot Considered : 133.63

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 133.63
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 133.63
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 118.62
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 15.02
15.02
Balance Plot Area 118.62

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 93.54
Proposed Coverage Area ( 68.46 % ) 91.48
Total Prop. Coverage Area ( 68.46 % ) 91.48
Balance coverage area ( 1.54 % ) 2.06
FAR CHECK
Perm. FAR Area ( 1.50 ) 200.45
Total Perm. FAR area 200.45
Residential FAR 182.96
Proposed FAR Area 193.20
Total Proposed FAR Area 193.20
Consumed FAR (Factor) 1.45
Balance FAR Area 7.25
BUA CHECK
Total Proposed BuiltUp Area 274.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 4.57 4.57
Proposed Road Width as per Master Plan 4.57 -
Road Widening Width 0 -
Plot size (as per measurement) 133.66 133.63




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 6.68 15.02 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 15.02 0.00 0.00 - 1.17 - 90.00 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 10 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (MR PAWAN KUMAR CHOUHAN) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (MR PAWAN KUMAR CHOUHAN) 8.87 8.40 8.40 8.40 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A (MR PAWAN KUMAR CHOUHAN) Second Floor 2.75 - 2.80 OK
First Floor 2.75 - 2.80 OK
Ground Floor 2.75 - 2.80 OK
Plinth 0.45 - 0.71 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (MR PAWAN KUMAR CHOUHAN) Terrace Floor 1.00 1.20 1.07 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (MR PAWAN KUMAR CHOUHAN) G + 2 3 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
93.54 91.48 OK
70% 68.46%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (MR PAWAN KUMAR CHOUHAN) - 91.48
Total Prop. Coverage Area - 91.48
Total Coverage Area 93.54 91.48


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
A (MR PAWAN KUMAR CHOUHAN) 1 274.44 81.25 182.96 10.23 193.19 193.19 01
Grand Total : 1 274.44 81.25 182.96 10.23 193.19 193.19 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (MR PAWAN KUMAR CHOUHAN)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 91.48 10.23 91.48 10.23
First Floor 91.48 91.48 91.48 91.48
Second Floor 91.48 91.48 91.48 91.48
Terrace Floor 0.00 0.00 0.00 0.00
Total : 274.44 193.19 274.44 193.19


[-] UnitBUA Table for Building :A (MR PAWAN KUMAR CHOUHAN) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
FIRST FLOOR PLAN SPLIT A FLAT 144.31 143.96 7 1
SECOND FLOOR PLAN SPLIT A FLAT 0.00 0.00 7 0
Total: - - 144.31 143.96 14 1


[-] Building :A (MR PAWAN KUMAR CHOUHAN)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Parking Resi. Stair
Ground Floor 91.48 81.25 0.00 10.23 10.23 10.23 00
First Floor 91.48 0.00 91.48 0.00 91.48 91.48 01
Second Floor 91.48 0.00 91.48 0.00 91.48 91.48 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 274.44 81.25 182.96 10.23 193.19 193.19 01
Total Number of Same Buildings : 1
Total : 274.44 81.25 182.96 10.23 193.19 193.19 01

[-] Table 4c-2

FARArea
Building FAR Area : 193.20
Existing FAR Area : 0.00
Perm.
200.45
Prop.
193.20
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (MR PAWAN KUMAR CHOUHAN) 4.57 MTR WIDE ROAD Access Road 2.00 2.01 1.50 1.50 0.90 0.91 - 0.00 OK







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A (MR PAWAN KUMAR CHOUHAN)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (MR PAWAN KUMAR CHOUHAN)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.900 1.066 0.250 0.279 0.200 0.140 - 2 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.900 1.066 0.250 0.279 0.200 0.140 - 2 - - 0.000 OK
SECOND FLOOR PLAN STAIRCASE 0.900 1.066 0.250 0.279 0.200 0.140 - 2 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.066 - 0.279 - 0.000 - 0 - - 2.590 OK


[-] Arch Projection Checks (Table 8c - a)

[-] For Building :A (MR PAWAN KUMAR CHOUHAN)
Floor Name Arch Proj Name Width Depth Area Status
Perm Prop Perm Prop Perm Prop
FIRST FLOOR PLAN CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 0.91 - 0.42 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
SECOND FLOOR PLAN CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 0.91 - 0.42 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.52 - 0.70 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK
CHHAJJA 0.75 0.46 - 1.83 - 0.84 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.93 - - 0.65 - - 1.42 - - 0.00 OK
RAIN WATER HARVESTING - - 3.38 - - 1.42 - - 2.38 - - 0.00 OK
SOLAR HEATING SYSTEM - - 2.55 - - 1.42 - - 1.79 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A (MR PAWAN KUMAR CHOUHAN)


[-] Floor:GROUND FLOOR PLAN



No Room Found.


[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:SECOND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 133.63 OK
Plot Width - 9.14 OK
Plot Depth - 14.62 OK
Access Width - 4.57 OK
Plot Frontage - 9.14 OK
Coverage Area 93.54 91.48 OK
FARArea
Bldg. FAR Area : 193.20
Sanctioned FAR Area : 0.00
200.45 193.20 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 3.60 (12 ft.) to 4.80 mt., the Floor Area Ratio-FAR shall be 1.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 10-15 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.0 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 3.6-4.8 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 10.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 3.6-4.8 mt. only G+2 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Arch Projection (1) No need to check
(2) Chhajja,Cornice or Weather shed of upto 0.75m width shall be permitted. {As per Rule No. 46.1}
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)