-
No Image Found

Detail Scrutiny Report

Mango NAC

Version Number: 1.0.31
Version Date: 30/06/2018
Report Generated On: 22-01-2019

[-] Collapse All


General Details
Region JHARKHAND URBAN LOCAL BODIES
District EAST SINGHBHUM
Authority MANGO NAC
Inward_No MNAC/BP/0048/W09/2018
Application Type General Proposal
Project Type Building Permission
Nature of Development New
Location of Development Area Old Area
City Area/TPScheme No NA
Village Pardih
Taluka 16
Architect Details
Architect Name MOHAMMAD BELAL NASIR
License No. MNAC/ENG/0007/2016
Architect Address HOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailID dreamdesign.jsr.bn@gmail.com
Architect Mobile No 9835307058
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No 1676
North -
South -
East -
West -
Owner's Details
Name RICHA KUMARI
Address RESIDENT OF FLAT NO. A/9 , SAHARA APARTMENT , SANGAM VIHAR, SONARI, JAMSHEDPUR
Email ID richadiwakar@gmail.com
Mobile No 7765804889
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 222.96
2 Plot area as per Document by Applicant 222.96
3 Physical area measured at site 222.96
4 Area as per Site Visit (Site Visit Report) 222.96
5 Area as per Drawing 222.96

Area of Plot Considered : 222.96

[-] Table 2b
Proposal Detail :
Unit Meters
Development Detail :
Plot PLOT
Plot Occupancy Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building Structure Non-Highrise
Building Type Single Detached House
Gross Plot Area 222.96
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 222.96
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 211.12
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 11.84
11.84
Balance Plot Area 211.12

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 156.07
Proposed Coverage Area ( 65.86 % ) 146.83
Total Prop. Coverage Area ( 65.86 % ) 146.83
Balance coverage area ( 4.14 % ) 9.24
FAR CHECK
Perm. FAR Area ( 2.50 ) 557.40
Total Perm. FAR area 557.40
Residential FAR 306.30
Proposed FAR Area 306.30
Total Proposed FAR Area 306.30
Consumed FAR (Factor) 1.37
Balance FAR Area 251.10
BUA CHECK
Total Proposed BuiltUp Area 306.31


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.1 6.10
Proposed Road Width as per Master Plan 6.1 -
Road Widening Width 0.2 -
Plot size (as per measurement) 222.96 222.96




[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 11.15 11.84 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 11.84 0.00 0.00 - 1.09 - 89.96 No Access Provided OK




[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 6 OK





[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A(RICHA KUMARI) Residential Residential Bldg/Apartment Non-Highrise



[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A(RICHA KUMARI) 11.65 6.00 6.00 6.00 OK




[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Status
Reqd Perm Prop
A(RICHA KUMARI) First Floor 2.60 - 3.00 OK
Ground Floor 2.60 - 3.00 OK
Plinth 0.45 - 0.45 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A(RICHA KUMARI) Terrace Floor 1.00 1.20 1.07 OK


[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A(RICHA KUMARI) G + 4 2 - 1 OK


[-] Coverage Check (Table 4b)
Permissible Proposed Status
156.07 146.83 OK
70% 65.86%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1(RICHA KUMARI) - 146.83
Total Prop. Coverage Area - 146.83
Total Coverage Area 156.07 146.83


[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
A(RICHA KUMARI) 1 306.31 306.31 306.31 306.31 01
Grand Total : 1 306.31 306.31 306.31 306.31 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A(RICHA KUMARI)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Ground Floor 146.83 146.83 146.83 146.83
First Floor 159.48 159.48 159.48 159.48
Terrace Floor 0.00 0.00 0.00 0.00
Total : 306.31 306.31 306.31 306.31


[-] UnitBUA Table for Building :A(RICHA KUMARI) UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT PDCRMSPLTT ABC FLAT 279.75 252.72 8 1
FIRST FLOOR PLAN SPLIT PDCRMSPLTT ABC FLAT 0.00 0.00 16 0
Total: - - 279.75 252.72 24 1


[-] Building :A(RICHA KUMARI)
Floor Name Total Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Resi.
Ground Floor 146.83 146.83 146.83 146.83 01
First Floor 159.48 159.48 159.48 159.48 00
Terrace Floor 0.00 0.00 0.00 0.00 00
Total : 306.31 306.31 306.31 306.31 01
Total Number of Same Buildings : 1
Total : 306.31 306.31 306.31 306.31 01

[-] Table 4c-2

FARArea
Building FAR Area : 306.30
Existing FAR Area : 0.00
Perm.
557.40
Prop.
306.30
Status
OK





[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1(RICHA KUMARI) 6.10 M WIDE MAINROAD Access Road 2.50 2.50 1.50 1.62 0.90 0.91 0.90 0.91 OK







[-] Inner Building Details (Table 6)


No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.



[-] Parking Details (Table 7)


NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Residential Bldg/Apartment, In Building: A(RICHA KUMARI)



[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A(RICHA KUMARI)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
GROUND FLOOR PLAN STAIRCASE 0.750 1.219 0.225 0.267 0.200 0.125 - 6 - - 0.000 OK
FIRST FLOOR PLAN STAIRCASE 0.750 1.219 0.225 0.267 0.200 0.125 - 6 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.267 - 0.000 - 0 2.100 - 2.470 OK



[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.81 - - 0.62 - - 1.31 - - 0.00 OK
RAIN WATER HARVESTING - - 0.88 - - 1.06 - - 1.06 - - 0.00 OK
SOLAR HEATING SYSTEM - - 0.83 - - 0.62 - - 1.34 - - 0.00 OK






[-] Floor Details (Table 9)


[-] Building:A(RICHA KUMARI)


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:FIRST FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.





[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area - 222.96 OK
Plot Width - 12.19 OK
Plot Depth - 18.29 OK
Access Width - 6.10 OK
Plot Frontage - 12.19 OK
Coverage Area 156.07 146.83 OK
FARArea
Bldg. FAR Area : 306.30
Sanctioned FAR Area : 0.00
557.40 306.30 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 10-15 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4) The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(5) The plinth or any part of a building shall be so located with respect to the surrounding ground level that adequate drainage of the site is assured. The height of the plinth (except in case of stilted parking) shall be not less than 0.45 mt. from the surrounding ground level {As per Rule No. 42.10}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of Winding staircase shall be mini. 0.75 mt.,Maximum rise 0.20 mt. & Minimum tread 0.225 mt. & Cabin height 2.1 mt {As per Rule No. 83.18}
(4) ; No Rule Defined
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) -
(6) No need to check distance from Building SOLAR HEATING SYSTEM
Building Level (Rooms)