No Image Found

Detail Scrutiny Report

Mango NAC

Version Number: 1.0.37
Version Date: 29/04/2019
Report Generated On: 18-07-2019
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO NAC
Inward_NoMNAC/BP/0011/W08/2019
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameGAURI SHANKAR SAHU
License No.MNAC/ENG/0025/2017
Architect AddressS-1, BLOCK-13, KRISHNA APARTMENT, ALOK VIHAR , GHORA BANDHA, TELCO, JAMSHEDPUR
Architect EmailIDgssahu7@gmail.com
Architect Mobile No7209935036
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No3114
NorthSurvey No. - other plot
SouthSurvey No. - other plot
EastSurvey No. - other plot
WestRoad Width - 18.3
Owner's Details
NameM JAWED AKHTAR
AddressZakir Nagar , Manzar Kazim Chowk, Old Purulia Road Mango
Email IDkm333411@gmail.com
Mobile No9304875452
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 1171.00
2 Plot area as per Document by Applicant 1001.00
3 Physical area measured at site 1001.00
4 Area as per Site Visit (Site Visit Report) 1001.00
5Area as per Drawing 1000.26

Area of Plot Considered : 1000.26

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 1000.26
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 1000.26
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 898.65
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 101.61
101.61
Balance Plot Area 898.65

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 500.13
Proposed Coverage Area ( 38.21 % ) 382.24
Total Prop. Coverage Area ( 38.21 % ) 382.24
Balance coverage area ( 11.79 % ) 117.89
FAR CHECK
Perm. FAR Area ( 2.50 ) 2500.65
Total Perm. FAR area 2500.65
Commercial FAR 2335.10
Proposed FAR Area 2355.29
Total Proposed FAR Area 2355.29
Consumed FAR (Factor) 2.35
Balance FAR Area 145.36
BUA CHECK
Total Proposed BuiltUp Area 2876.89


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 1000 meter -
Existing Road Width 15 15.00
Proposed Road Width as per Master Plan 15 -
Road Widening Width 0 -
Plot size (as per measurement) 1001 1000.26
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)

[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 100.03 101.61 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 101.61 0.00 0.00 - 4.50 - 90.00 No Access Provided OK



[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 8 8 OK


[-] Building Details (Table 4)

[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (M JAWED AKHTAR) Commercial Commercial Bldg Multistoried


[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (M JAWED AKHTAR) 29.01 19.10 19.10 19.10 OK



[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (M JAWED AKHTAR) Fifth Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
Fourth Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
Third Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
Second Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
First Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
Ground Floor 2.75 - 3.00 2.75 - 2.89 2.40 - 2.62 OK
Parking Floor - - 2.52 2.40 - 2.41 2.10 - 2.14 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (M JAWED AKHTAR) Terrace Floor 1.00 1.20 1.11 OK

[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (M JAWED AKHTAR) - 7 - 8 OK

[-] Coverage Check (Table 4b)
Permissible Proposed Status
500.13 382.24 OK
50% 38.21%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
A-1 (M JAWED AKHTAR) - 382.24
Total Prop. Coverage Area - 382.24
Total Coverage Area 500.13 382.24

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Ramp Parking Commercial Stair
A (M JAWED AKHTAR) 1 2876.89 41.04 76.04 2.28 49.33 352.93 2335.10 20.19 2355.27 2355.27 08
Grand Total : 1 2876.89 41.04 76.04 2.28 49.33 352.93 2335.10 20.19 2355.27 2355.27 08


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (M JAWED AKHTAR)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Parking Floor 431.57 20.19 431.57 20.19
Ground Floor 382.24 382.24 382.24 382.24
First Floor 382.20 375.36 382.20 375.36
Second Floor 420.22 394.37 420.22 394.37
Third Floor 420.22 394.37 420.22 394.37
Fourth Floor 420.22 394.37 420.22 394.37
Fifth Floor 420.22 394.37 420.22 394.37
Terrace Floor 0.00 0.00 0.00 0.00
Total : 2876.89 2355.27 2876.89 2355.27


[-] UnitBUA Table for Building :A (M JAWED AKHTAR)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SHOP 3.74X2.90 SHOP 130.96 128.82 8 2
SHOP 3.74X2.90 SHOP 78.35 76.10 6
FIRST FLOOR PLAN SHOP 3.74X2.90 SHOP 117.06 113.82 9 2
SHOP 3.74X2.90 SHOP 92.90 90.34 7
TYPICAL - 2& 3 FLOOR PLAN SHOP 3.74X2.90 SHOP 117.06 113.82 9 4
SHOP 3.74X2.90 SHOP 92.90 90.34 7
Total: - - 1665.94 1619.43 68 8


[-] Building :A (M JAWED AKHTAR)
Floor Name Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Lift Balcony Accessory Use Ramp Parking Commercial Stair
Parking Floor 431.57 6.84 0.00 2.28 49.33 352.93 0.00 20.19 20.19 20.19 00
Ground Floor 382.24 0.00 0.00 0.00 0.00 0.00 382.24 0.00 382.24 382.24 02
First Floor 382.20 6.84 0.00 0.00 0.00 0.00 375.36 0.00 375.36 375.36 02
Second Floor 420.22 6.84 19.01 0.00 0.00 0.00 394.37 0.00 394.37 394.37 02
Third Floor 420.22 6.84 19.01 0.00 0.00 0.00 394.37 0.00 394.37 394.37 02
Fourth Floor 420.22 6.84 19.01 0.00 0.00 0.00 394.37 0.00 394.37 394.37 00
Fifth Floor 420.22 6.84 19.01 0.00 0.00 0.00 394.37 0.00 394.37 394.37 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 2876.89 41.04 76.04 2.28 49.33 352.93 2335.10 20.19 2355.27 2355.27 08
Total Number of Same Buildings : 1
Total : 2876.89 41.04 76.04 2.28 49.33 352.93 2335.10 20.19 2355.27 2355.27 08
[-] Table 4c-2

FARArea
Building FAR Area:2355.29
Existing FAR Area :0.00
Perm.
2500.65
Prop.
2355.29
Status
OK




[-] Margin Checks (Table 5)
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (M JAWED AKHTAR) 15.0 M WIDE OLD PURULIA ROAD 6.50 6.51 4.50 4.50 4.50 5.15 4.50 5.19 OK






[-] Inner Building Details (Table 6)

[-] Balcony Details (Table 6c)

[-] For Building:A (M JAWED AKHTAR)
Floor Name Balcony Name Width Status
Perm Prop
TYPICAL - 4& 5 FLOOR PLAN BALCONY 1.20 1.15 OK
BALCONY 1.20 0.15 OK
TYPICAL - 2& 3 FLOOR PLAN BALCONY 1.20 0.15 OK
BALCONY 1.20 1.15 OK



For PWork At Layout:

No Balcony Found.


[-] Passage Details

[-] For Building :A (M JAWED AKHTAR)
Floor Name Passage Name Area Width Length Status
Prop Reqd Prop Perm Prop
GROUND FLOOR PLAN 1.83M WIDE PASSAGE 131.19 1.00 1.46 - 18.87 OK
FIRST FLOOR PLAN 1.83M WIDE PASSAGE 126.02 1.00 1.46 - 18.87 OK
TYPICAL - 2& 3 FLOOR PLAN 1.83M WIDE PASSAGE 126.02 1.00 1.46 - 18.87 OK


[-] Lift Details (Table 6d)
Building Name Height Number Of Lift(s) Status
Prop Reqd Prop
A (M JAWED AKHTAR) 19.10 2 2 OK

[-] Lift Check Table

[-] For Building :A (M JAWED AKHTAR)
Floor Name Lift Name Width Depth Status
Reqd Prop Reqd Prop
PARKING FLOOR PLAN Lift 1.70 1.80 1.90 1.90 OK
Lift 1.70 1.80 1.90 1.90 OK
GROUND FLOOR PLAN Lift 1.70 1.80 1.90 1.90 OK
Lift 1.70 1.80 1.90 1.90 OK
FIRST FLOOR PLAN Lift 1.70 1.80 1.90 1.90 OK
Lift 1.70 1.80 1.90 1.90 OK
TYPICAL - 4& 5 FLOOR PLAN Lift 1.70 1.80 1.90 1.90 OK
Lift 1.70 1.80 1.90 1.90 OK
TERRACE FLOOR PLAN Lift Machine Room 1.70 1.80 1.90 1.90 OK
Lift Machine Room 1.70 1.80 1.90 1.90 OK
TYPICAL - 2& 3 FLOOR PLAN Lift 1.70 1.80 1.90 1.90 OK
Lift 1.70 1.80 1.90 1.90 OK



[-] Parking Details (Table 7)

[-] Required Parking(Table 7a)
Building Name Type SubUse Area (Sq.mt.) Units Car TwoWheeler
Reqd. Prop. Reqd./Unit Reqd. Prop. Reqd./Unit Reqd. Prop.
A (M JAWED AKHTAR) Commercial Commercial Bldg > 0 100 1656.63 1 12 - - - -
> 0 100 1656.63 - - - 1 35 -
Total : - - - - 12 6 - 35 36

[-] Parking Check (Table 7b)
Vehicle Type Reqd. Prop. Status
No. Area No. Area
Car - - 6 75.00 OK
Total Car 12 150.00 6 75.00 FAILED
TwoWheeler - - 36 72.00 OK
Total TwoWheeler 35 70.00 36 72.00 OK
Other Parking - - - 304.93 OK
Total 220.00 523.93 OK

Individual Parking Checks (Table 7c)
Dimensions and Area for all Vehicle(s) are as per the Rules

Driveway Parking Checks (Table 7d)
Plot Level Parking Driveway is as per the Rules
Floor Level Parking Driveway is as per the Rules


[-] Exemption Details (Table 8)



Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (M JAWED AKHTAR)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
PARKING FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.140 - 9 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.305 0.200 0.140 - 9 - - 0.000 OK
GROUND FLOOR PLAN Escalator - 0.000 - 0.000 - 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.167 - 9 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.305 0.200 0.167 - 9 - - 0.000 OK
FIRST FLOOR PLAN Escalator - 0.000 - 0.000 - 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.167 - 9 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.305 0.200 0.167 - 9 - - 0.000 OK
TYPICAL - 4& 5 FLOOR PLAN STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.167 - 9 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.219 - 0.305 - 0.000 - 0 - - 2.639 OK
STAIRCASE - 1.067 - 0.254 - 0.000 - 0 - - 2.639 OK
TYPICAL - 2& 3 FLOOR PLAN Escalator - 0.000 - 0.000 - 0.000 - 0 - - 0.000 OK
STAIRCASE 0.900 1.067 0.250 0.254 0.200 0.167 - 9 - - 0.000 OK
STAIRCASE 0.900 1.219 0.250 0.305 0.200 0.167 - 9 - - 0.000 OK


[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
11.51 mt. long 1.42 mt. High 4.5 mt. Wide Ramp 4.50 4.65 1.00 1.42 1.00 : 7.00 - 01 : 09 OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (M JAWED AKHTAR) PARKING FLOOR PLAN 1 1 OK


[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Toilet - 5.00 2.28 - - 1.20 - - 1.90 - - 0.00 OK
RAIN WATER HARVESTING - - 9.00 - - 3.00 - - 3.00 - - 0.00 OK
ENT.GATE - - 1.09 - - 0.24 - - 4.50 - - 0.00 OK
SOLAR HEATING SYSTEM - - 4.00 - - 2.00 - - 2.00 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (M JAWED AKHTAR) Rain Water Harvesting 1 - 1 OK
Toilet 1 - 1 OK
Entrance Gate 1 - 1 OK


[-] Floor Details (Table 9)


[-] Building:A (M JAWED AKHTAR)


[-] Floor:PARKING FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:FIRST FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.

[-] Floor:TYPICAL - 4& 5 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 2& 3 FLOOR PLAN



Not Required to Check Dimensions and Area of all the Rooms on this Floor Rule.




[-] Summary (Table 10)

Name Perm./Reqd. Proposed Status
Plot Area 1000.00 1000.26 OK
Plot Width - 28.60 OK
Plot Depth - 34.97 OK
Access Width 6.10 15.00 OK
Plot Frontage - 33.76 OK
Coverage Area 500.13 382.24 OK
FARArea
Bldg. FAR Area : 2355.29
Sanctioned FAR Area :0.00
2500.65 2355.29 OK





[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Width The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Depth The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Multistoried Building, having Building Height 16.40-19.25 mt.,Margin required in Front shall be 6.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) Stilt floor is of minimum height of 2.4 meter. From floor to ceiling and not less than 2.10 mt. from the soffit of beams
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Balcony For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)