-
No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.60  
Version Date: 16/10/2020 
Report Generated On: 27-08-2021 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0021/W08/2019/REV1
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentRevision
Revise Case TypeBefore 15th Sept 2004
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameMOHAMMAD BELAL NASIR
License No.MNAC/ENG/0007/2016
Architect AddressHOLDING No: 02, CROSS ROAD No:1/D, AZAD NAGAR, MANGO
Architect EmailIDdreamdesign.jsr.bn@gmail.com
Architect Mobile No9835307058
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No3412
North -
South -
East -
West -
Owner's Details
NameSHABANA PERWEEN
AddressRESIDENT OF HOUSE NO. 61, HAYAT NAGAR, DIMNA BASTI, NEAR LAL BUILDING, PO- MGM, JAMSHEDPUR
Email IDdreamdesign.jsr@gmail.com
Mobile No9631773114
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 300.31
2 Plot area as per Document by Applicant 300.31
3 Physical area measured at site 300.31
4 Area as per Site Visit (Site Visit Report) 300.31
5Area as per Drawing 300.31

Area of Plot Considered : 300.31

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 300.31
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 300.31
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 271.85
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 28.46
28.46
Balance Plot Area 271.85

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 180.19
Proposed Coverage Area ( 59.67 % ) 179.19
Total Prop. Coverage Area ( 59.67 % ) 179.19
Balance coverage area ( 0.33 % ) 1.00
FAR CHECK
Perm. FAR Area ( 2.50 ) 750.78
Total Perm. FAR area 750.78
Residential FAR 730.13
Proposed FAR Area 750.48
Total Proposed FAR Area 750.48
Consumed FAR (Factor) 2.50
Balance FAR Area 0.30
BUA CHECK
Total Proposed BuiltUp Area 919.33


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 6.7 6.70
Proposed Road Width as per Master Plan 6.7 -
Road Widening Width 0 -
Plot size (as per measurement) 300.31 300.31
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 300.31 OK
Plot Width Mt. - - 11.14 OK
Plot Depth Mt. - - 26.96 OK
Access Width Mt. - - 6.70 OK
Plot Frontage Mt. - - 10.85 OK
Coverage Area Sq.Mt. - 180.19 179.19 OK
FAR Area Sq.Mt. - 750.78 750.48 OK
Consumed FAR Sq.Mt. - 2.50 2.50 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 15.02 28.46 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 28.46 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 1.46 OK
Tree Cover (Plantation) - Angle Degree - 87.46 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
A-1(SHABANA PERWEEN) Front Margin... 6.70M WIDEMAINROAD Access Road Mt. 3.00 - 3.82 OK
Rear Margin Mt. 2.25 - 3.04 OK
Side1 Margin Mt. 0.90 - 0.92 OK
Side2 Margin Mt. 0.90 - 1.00 OK
A-1(SHABANA PERWEEN) Basement Front Margin... 6.70M WIDEMAINROAD Access Road Mt. 3.00 - 3.82 OK
Basement Rear Margin Mt. 2.25 - 3.04 OK
Basement Side1 Margin Mt. 0.90 - 0.91 OK
Basement Side2 Margin Mt. 0.90 - 1.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A(SHABANA PERWEEN) Height Mt. 13.87 12.20 OK
A(SHABANA PERWEEN) Third Floor - Height Mt. 2.75 - 2.88 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Second Floor - Height Mt. 2.75 - 2.88 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
First Floor - Height Mt. 2.75 - 2.88 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Ground Floor - Height Mt. 2.75 - 2.88 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.65 OK
Basement Floor - Height Mt. 2.40 - 2.88 OK
Basement Floor - Clear Height Mt. 2.40 - 2.75 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.65 OK
A(SHABANA PERWEEN) Terrace Floor - Height Mt. - - 1.06 OK
A(SHABANA PERWEEN) Basement Floor - Height Below GL Mt. - 1.00 OK
Basement Floor - Area Sq.Mt. - 179.19 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A(SHABANA PERWEEN) Area Sq.Mt. - 179.19 OK
Status - OK
Total Area Sq.Mt. - 179.19 OK
A(SHABANA PERWEEN) No. of Basement Floor No. 1 1 OK
A(SHABANA PERWEEN) No. of Floors No. G + 4 4 OK
No. of Tenements No. - 1 OK
A(SHABANA PERWEEN) Number Of Lift(s) No. - 1 OK
Number Of Strature Lift(s) No. - - OK
Capacity Of Lift(s) Passanger No. - 6 OK
A(SHABANA PERWEEN) FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
TERRACE FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
TERRACE FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
BASEMENT FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.75 OK
BASEMENT FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.91 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
THIRD FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
THIRD FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
SECOND FLOOR PLAN - Lift - Width Mt. 1.70 1.75 OK
SECOND FLOOR PLAN - Lift - Depth Mt. 1.90 1.91 OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.219 OK
STAIRCASE - Tread Width Mt. - 0.267 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.470 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
THIRD FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
SECOND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.219 OK
STAIRCASE - Tread Width Mt. 0.250 0.267 OK
STAIRCASE - Riser Height Mt. 0.200 0.120 OK
STAIRCASE - Riser No. On Flight No. - 8 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Sewage Treatment Plant Area Sq.Mt. - - 0.81 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 1.31 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.88 OK
Width Mt. - - 1.05 OK
Depth Mt. - - 1.06 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.68 OK
Width Mt. - - 0.23 OK
Depth Mt. - - 3.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.83 OK
Width Mt. - - 0.62 OK
Depth Mt. - - 1.34 OK
Height Mt. - - - OK
A(SHABANA PERWEEN) Rain Water Harvesting - No No. 1 - 1 OK
Solar Water Heating System - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 7.00 mt. long 1.00 mt. High 3.60 mt. Wide Natural Slope - Width Mt. - 3.60 OK
7.00 mt. long 1.00 mt. High 3.60 mt. Wide Natural Slope - Depth Mt. - 1.00 OK
7.00 mt. long 1.00 mt. High 3.60 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A(SHABANA PERWEEN) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 6.10 (20 ft.) to 7.5 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 21-27 mt. and Plot width 10-15 mt., Margin required in Front shall be 3.0 mt., Rear 2.25 mt. and 0.9 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 6.10-7.50 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 16.4 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 6.1-7.5 mt. only G+4 floors shall be allowed {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
(2) For Individual residential buildings having more than 150 sq m. plinth area, Provisions of Solar Water Heating System shall be done Solar Water Heating System
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)