No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 17-03-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0007/W08/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaNew Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect Namesm shahreyar
License No.MNAC/ARC/0026/2017
Architect AddressAL-TAUHID APARTMENT,GROUND FLOOR,NERA ROAD NO-13,OLD PURULIA ROAD(E),ZAKIRNAGAR,AZADNAGAR,MANGO
Architect EmailIDadiction.arch@gmail.com
Architect Mobile No7004876409
Plot Details
Plot Use Commercial
Plot SubUse Shop
PlotNearbyReligiousStructure NA
Plot/SubPlot No3280 and 3252
NorthRoad Width - 3.10
SouthPlot No. - nij
EastRoad Width - 11.15
WestPlot No. - nij
Owner's Details
Namemd israil and md shabuddin and others
Addressold purulia road no 12 zakirnagar mango
Email IDimperial.archi@gmail.com
Mobile No8240512041
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 728.67
2 Plot area as per Document by Applicant 728.67
3 Physical area measured at site 728.67
4 Area as per Site Visit (Site Visit Report) 728.67
5Area as per Drawing 728.67

Area of Plot Considered : 728.67

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse Shop
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 728.67
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 728.67
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 653.61
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 75.06
75.06
Balance Plot Area 653.61

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 364.33
Proposed Coverage Area ( 23.74 % ) 172.95
Total Prop. Coverage Area ( 23.74 % ) 172.95
Balance coverage area ( 26.26 % ) 191.38
FAR CHECK
Perm. FAR Area ( 2.50 ) 1821.67
Total Perm. FAR area 1821.67
Commercial FAR 1221.24
Proposed FAR Area 1234.02
Total Proposed FAR Area 1234.02
Consumed FAR (Factor) 1.69
Balance FAR Area 587.65
BUA CHECK
Total Proposed BuiltUp Area 1696.96


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 250 meter and upto 300 meter -
Existing Road Width 11.1 11.10
Proposed Road Width as per Master Plan 11.1 -
Road Widening Width 0 -
Plot size (as per measurement) 728.67 728.67
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 728.67 OK
Plot Width Mt. - - 34.43 OK
Plot Depth Mt. - - 21.16 OK
Access Width Mt. 6.10 - 11.10 OK
Plot Frontage Mt. - - 34.85 OK
Coverage Area Sq.Mt. - 364.33 172.95 OK
FAR Area Sq.Mt. - 1821.67 1234.02 OK
Consumed FAR Sq.Mt. - 2.50 1.69 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 36.43 75.06 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 75.06 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 3.46 OK
Tree Cover (Plantation) - Angle Degree - 89.84 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 8 OK
Car In Area Sq.Mt. - - 162.50 OK
Total Car In Area Sq.Mt. 162.50 - 162.50 OK
TwoWheeler In Area Sq.Mt. - - 54.00 OK
Two Stack. TwoWheeler In Area Sq.Mt. - - 30.00 OK
Total TwoWheeler In Area Sq.Mt. 78.00 - 84.00 OK
Other Parking In Area Sq.Mt. - - 222.75 OK
A-1 (COMMERCIAL) Front Margin... 11.1 METER WIDE ROAD Mt. 6.00 - 6.50 OK
Rear Margin Mt. 4.00 - 4.50 OK
Side1 Margin Mt. 4.00 - 4.50 OK
Side2 Margin Mt. 4.00 - 4.50 OK
A-1 (COMMERCIAL) Basement Front Margin... 11.1 METER WIDE ROAD Mt. 3.00 - 3.00 OK
Basement Rear Margin Mt. 3.00 - 3.00 OK
Basement Side1 Margin Mt. 3.00 - 3.00 OK
Basement Side2 Margin Mt. 3.00 - 3.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (COMMERCIAL) Height Mt. 23.10 14.25 OK
A (COMMERCIAL) Fourth Floor - Height Mt. 2.75 - 2.85 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.75 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Third Floor - Height Mt. 2.75 - 2.85 OK
Third Floor - Clear Height Mt. 2.75 - 2.75 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Second Floor - Height Mt. 2.75 - 2.85 OK
Second Floor - Clear Height Mt. 2.75 - 2.75 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
First Floor - Height Mt. 2.75 - 2.85 OK
First Floor - Clear Height Mt. 2.75 - 2.75 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Ground Floor - Height Mt. 2.75 - 2.85 OK
Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
Basement Floor - Height Mt. 2.40 - 2.85 OK
Basement Floor - Clear Height Mt. 2.40 - 2.75 OK
Basement Floor - Beam Clear Height Mt. 2.10 - 2.55 OK
A (COMMERCIAL) Terrace Floor - Height Mt. 1.00 1.20 1.01 OK
A (COMMERCIAL) Basement Floor - Height Below GL Mt. - 2.39 OK
Basement Floor - Area Sq.Mt. - 377.77 OK
Basement Floor - Ventilation Area (Sq.mt.) Sq.Mt. - - OK
A (COMMERCIAL) Area Sq.Mt. - 377.77 OK
Status - OK
Total Area Sq.Mt. - 377.77 OK
A (COMMERCIAL) No. of Basement Floor No. 1 1 OK
A (COMMERCIAL) No. of Floors No. G + 6 5 OK
No. of Tenements No. - 9 OK
A (COMMERCIAL) TYPICAL - 1- 4 FLOOR PLAN - Passage Name - OK
TYPICAL - 1- 4 FLOOR PLAN - Width Mt. 1.00 3.05 OK
TYPICAL - 1- 4 FLOOR PLAN - Length Mt. - 6.39 OK
TYPICAL - 1- 4 FLOOR PLAN - Passage Name - OK
TYPICAL - 1- 4 FLOOR PLAN - Width Mt. 1.00 3.73 OK
TYPICAL - 1- 4 FLOOR PLAN - Length Mt. - 9.23 OK
A (COMMERCIAL) Number Of Lift(s) No. 1 1 OK
A (COMMERCIAL) BASEMENT FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 1.90 OK
BASEMENT FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.50 OK
TYPICAL - 1- 4 FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 1.90 OK
TYPICAL - 1- 4 FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.50 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 2.83 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 3.89 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 13 Persons - Width Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - PASSENGER LIFT for 13 Persons - Depth Mt. 2.50 2.50 OK
BASEMENT FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.524 OK
STAIRCASE - Tread Width Mt. 0.250 0.305 OK
STAIRCASE - Riser Height Mt. 0.200 - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 1- 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.524 OK
STAIRCASE - Tread Width Mt. 0.250 0.305 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.524 OK
STAIRCASE - Tread Width Mt. - 0.305 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.473 OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.524 OK
STAIRCASE - Tread Width Mt. 0.250 0.305 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 6 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
Toilet Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
Area Sq.Mt. - 5.00 3.34 OK
Width Mt. - - 1.37 OK
Depth Mt. - - 2.44 OK
Height Mt. - - - OK
RAIN WATER HARVESTING Area Sq.Mt. - - 0.05 OK
Width Mt. - - 0.08 OK
Depth Mt. - - 0.66 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 0.13 OK
Width Mt. - - 0.07 OK
Depth Mt. - - 1.85 OK
Height Mt. - - - OK
Entrance Lobby Area Sq.Mt. - 12.00 11.60 OK
Width Mt. - - 3.95 OK
Depth Mt. - - 6.39 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 0.05 OK
Width Mt. - - 0.08 OK
Depth Mt. - - 0.66 OK
Height Mt. - - - OK
Generator Room Area Sq.Mt. - - 3.80 OK
Width Mt. - - 1.78 OK
Depth Mt. - - 2.13 OK
Height Mt. - - - OK
A (COMMERCIAL) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 1 OK
PLOT 10.50 mt. long 1.50 mt. High 3.83 mt. Wide Natural Slope - Width Mt. - 3.60 OK
10.50 mt. long 1.50 mt. High 3.83 mt. Wide Natural Slope - Depth Mt. - 1.50 OK
10.50 mt. long 1.50 mt. High 3.83 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (COMMERCIAL) - BASEMENT FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In New Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In New Area, for Non-Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 21-27 mt. and Plot width 33-39 mt., Margin required in Front shall be 6.0 mt., Rear 4.0 mt. and 4.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For new area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 16}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For new area location,on Road width 9.1-12.2 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 16 and modified as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) -
(4) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(5) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) Entrance Lobby of maximum size of 12 sq.m. shall be taken Free from FAR
(7) No need to check distance from Building Entrance Lobby
(8) -
(9) No need to check distance from Building SOLAR HEATING SYSTEM
(10) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(11) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)