-
No Image Found   

Detail Scrutiny Report

Mango Municipal Corporation

Version Number: 1.0.61  
Version Date: 16/10/2020 
Report Generated On: 18-01-2022 
 
[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0066/W10/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameAnoop Kumar
License No.MNAC/ENG/0006/2016
Architect AddressFLAT NO- 4503, CHEESE BERRY BLOCK, SAHARA GARDEN CITY ADITYAPUR-2, JAMSHEDPUR , JHARKHAND
Architect EmailIDanoop7117@gmail.com
Architect Mobile No9431117509
Plot Details
Plot Use Residential
Plot SubUse Bungalow/ Dwelling / Non Apartment
PlotNearbyReligiousStructure NA
Plot/SubPlot No205
NorthPlot No. - SMT. SUNAYNA DUBEY
SouthPlot No. - BIPIN DUBEY
EastPlot No. - ONE DURNA
WestRoad Width - 12.10 MTR DIMNA MANGO MAIN ROAD
Owner's Details
NameRAJ KUMAR MENGOTIA
AddressDimna Road Mango, Jamshedpur
Email IDravim76@gmail.com
Mobile No9431113581
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 129.49
2 Plot area as per Document by Applicant 129.49
3 Physical area measured at site 129.49
4 Area as per Site Visit (Site Visit Report) 129.49
5Area as per Drawing 128.44

Area of Plot Considered : 128.44

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyResidential
Plot SubUse Bungalow/ Dwelling / Non Apartment
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 128.44
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 128.44
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 110.06
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 18.38
18.38
Balance Plot Area 110.06

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 70.00 % ) 89.91
Proposed Coverage Area ( 65.03 % ) 83.53
Total Prop. Coverage Area ( 65.03 % ) 83.53
Balance coverage area ( 4.97 % ) 6.38
FAR CHECK
Perm. FAR Area ( 2.50 ) 321.10
Total Perm. FAR area 321.10
Residential FAR 250.60
Proposed FAR Area 261.23
Total Proposed FAR Area 261.23
Consumed FAR (Factor) 2.03
Balance FAR Area 59.87
BUA CHECK
Total Proposed BuiltUp Area 335.33


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 12.1 12.10
Proposed Road Width as per Master Plan 12.1 -
Road Widening Width 0 -
Plot size (as per measurement) 129.49 128.44
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK


[-] Plot Level Checking (Table 3)
   
[-] Common Plot Checks (Table 3b)
Name Total Area Status
Reqd Prop
Common Plot 6.42 18.38 OK


[-] Common Plot Checks (Table 3b)
Name Minimum Area Coverage Area Width Angle Access Status
Reqd Prop Perm Prop Reqd Prop Reqd Prop
Tree Cover (Plantation) - 18.38 0.00 0.00 - 1.14 - 90.00 No Access Provided OK


   
   
[-] Tree Details (Table 3g)
Name Nos Of Trees Status
Reqd Prop
Tree 2 8 OK
   
   
   
   
   


[-] Building Details (Table 4)
   
[-] Building USE/SUBUSE Details Building USE/SUBUSE Details
Building Name Building Use Building SubUse Building Structure
A (RAJ KUMAR MENGOTIA) Residential Bungalow/ Dwelling / Non Apartment Non-Highrise
   
   
   
[-] Height Details (4a)



[-] Total Height (Table 4a-1)
Building Height Height (From GL) Height (From Street LVL) Status
Perm Prop
A (RAJ KUMAR MENGOTIA) 21.24 9.20 9.20 9.20 OK


   
   
[-] Floor Height Check (Table 4a-2)
Building Name Floor Name Height Clear Height Beam Clear Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
A (RAJ KUMAR MENGOTIA) Second Floor 2.75 - 3.07 2.75 - 2.97 2.40 - 2.88 OK
First Floor 2.75 - 3.07 2.75 - 2.97 2.40 - 2.88 OK
Ground Floor 2.75 - 3.07 2.75 - 2.97 2.40 - 2.88 OK
Basement Floor 2.40 - 3.07 2.40 - 2.97 2.10 - 2.88 OK


[-] Parapet Height Check (Table 4a-2.1)
Building Name Floor Name Height Status
Reqd Perm Prop
A (RAJ KUMAR MENGOTIA) Terrace Floor - - 1.06 OK
   
   
[-] Basement Floor Check (Table 4a-3)
Building Name Floor Name Height Below GL Area Ventilation Area (Sq.mt.) Status
Perm Prop Perm Prop Reqd Prop
A (RAJ KUMAR MENGOTIA) Basement Floor - 3.07 - 84.74 - 0.00 OK


[-] Basement Floor Area Check
Building Name Area Status
Perm Prop
A (RAJ KUMAR MENGOTIA) - 84.74
Total - 84.74 OK

1 [-] Basement Margin Check
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
  A-1 (RAJ KUMAR MENGOTIA)   12.10 MTR WIDE MAIN ROAD Access Road 2.50 3.09 1.50 1.53 0.90 0.92 - 0.00 OK

    >
   
   
[-] Floor Number Check (Table 4a-4)
Building Name No. of Floors No. of Tenements Status
Perm Prop Perm Prop
A (RAJ KUMAR MENGOTIA) G + 6 3 - 1 OK


[-] Basement Floor Number Check
Building Name No. of Basement Floor Status
Perm Prop
A (RAJ KUMAR MENGOTIA) 1 1 OK
 
   
    [-] Coverage Check (Table 4b)
Permissible Proposed Status
89.91 83.53 OK
70% 65.03%

[-] Individual Coverage Check
Coverage Area Perm. Prop.
  A-1 (RAJ KUMAR MENGOTIA) - 83.53
  Total Prop. Coverage Area - 83.53
  Total Coverage Area 89.91 83.53

[-] FAR & Tenement Details (Table 4c-1)
Building No. of Same Bldg Gross Built Up Area (Sq.mt.) Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Parking Resi. Stair
A (RAJ KUMAR MENGOTIA) 1 338.93 3.60 335.33 74.11 250.59 10.63 261.22 261.22 01
Grand Total : 1 338.93 3.60 335.33 74.11 250.59 10.63 261.22 261.22 01


[-] Buildingwise Floor FAR Details
Floor Name Building Name Total
A (RAJ KUMAR MENGOTIA)
Proposed Built Up Area (Sq.mt.) Proposed FAR Area (Sq.mt.) Total Proposed Built Up Area (Sq.mt.) Total FAR Area (Sq.mt.)
Basement Floor 84.74 10.63 84.74 10.63
Ground Floor 83.53 83.53 83.53 83.53
First Floor 83.53 83.53 83.53 83.53
Second Floor 83.53 83.53 83.53 83.53
Terrace Floor 0.00 0.00 0.00 0.00
Total : 335.33 261.22 335.33 261.22


[-] UnitBUA Table for Building :A (RAJ KUMAR MENGOTIA)
UnitBUA CALCULATION
FLOOR Name UnitBUA Type UnitBUA Area Carpet Area No. of Rooms No. of Tenement
GROUND FLOOR PLAN SPLIT A FLAT 185.69 185.59 4 1
TYPICAL - 1 & 2 FLOOR PLAN SPLIT A FLAT 0.00 0.00 4 0
Total: - - 185.69 185.59 12 1


[-] Building :A (RAJ KUMAR MENGOTIA)
Floor Name Gross Builtup Area Deductions From Gross BUA(Area in Sq.mt.) Total Built Up Area (Sq.mt.) Deductions (Area in Sq.mt.) Proposed FAR Area (Sq.mt.) Add Area In FAR (Sq.mt.) Total FAR Area (Sq.mt.) Total Consumed Additional FAR Area (Sq.mt.) Tnmt (No.)
Cutout Parking Resi. Stair
Basement Floor 84.74 0.00 84.74 74.11 0.00 10.63 10.63 10.63 00
Ground Floor 84.73 1.20 83.53 0.00 83.53 0.00 83.53 83.53 01
First Floor 84.73 1.20 83.53 0.00 83.53 0.00 83.53 83.53 00
Second Floor 84.73 1.20 83.53 0.00 83.53 0.00 83.53 83.53 00
Terrace Floor 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 00
Total : 338.93 3.60 335.33 74.11 250.59 10.63 261.22 261.22 01
Total Number of Same Buildings : 1
Total : 338.93 3.60 335.33 74.11 250.59 10.63 261.22 261.22 01
[-] Table 4c-2

  FAR Area
Building FAR Area:261.23
Existing FAR Area :0.00
Perm.
321.10
Prop.
261.23
Status
OK




[-] Margin Checks (Table 5)
   
[-] Plot Margin (Table 5a)
Building / Wing Road Name Front Side Rear Side Side1 Side2 Status
Reqd. Prop. Reqd. Prop. Reqd. Prop. Reqd. Prop.
A-1 (RAJ KUMAR MENGOTIA) 12.10 MTR WIDE MAIN ROAD Access Road 2.50 3.09 1.50 1.53 0.90 0.92 - 0.00 OK






[-] Inner Building Details (Table 6)
   

No OTS/Duct/VShaft/Balcony/Passage/Lift/Tenements Found.
   


[-] Parking Details (Table 7)
   

NO PARKING CHECK REQUIRED FOR SINGLE DWELLING UNIT. Bungalow/ Dwelling / Non Apartment, In Building: A (RAJ KUMAR MENGOTIA)
   


[-] Exemption Details (Table 8)
   


Not Required to Check StairCase Number Rule.


[-] Staircase Checks (Table 8a-1)


[-] For Building :A (RAJ KUMAR MENGOTIA)
Floor Name StairCase Name Flight Width Tread Width Riser Height Riser No. On Flight Cabin Ht. Status
Reqd Prop Reqd Prop Perm Prop Perm Prop Reqd Perm Prop
BASEMENT FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.000 - 0 - - 0.000 OK
GROUND FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.153 - 8 - - 0.000 OK
TYPICAL - 1 & 2 FLOOR PLAN STAIRCASE 0.900 1.073 0.250 0.268 0.200 0.153 - 8 - - 0.000 OK
TERRACE FLOOR PLAN STAIRCASE - 1.073 - 0.268 - 0.000 - 0 - - 2.453 OK

   
   
   

[-] Ramp Checks (Table 8b-a)
Ramp Name Width Depth Slope Status
Reqd Prop Reqd Prop Reqd Perm Prop
3.00 mt. long 1.50 mt. High 5.31 mt. Wide Natural Slope - 3.00 - 1.50 - - - OK


[-] Ramp Checks (Table 8b)
Building Name Floor Name No. Status
Reqd Prop
A (RAJ KUMAR MENGOTIA) BASEMENT FLOOR PLAN 1 1 OK

   
   
   
[-] Accessory Use Check (Table 8d)
Accessory Use Name Area Width Depth Height Status
Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop Reqd Perm Prop
Sewage Treatment Plant - - 0.93 - - 0.78 - - 1.20 - - 0.00 OK
RAIN WATER HARVESTING - - 1.76 - - 1.21 - - 1.45 - - 0.00 OK
ENT.GATE - - 0.92 - - 0.34 - - 2.68 - - 0.00 OK
SOLAR HEATING SYSTEM - - 1.39 - - 0.96 - - 1.45 - - 0.00 OK





[-] Accessory Use No. Checks
Building Name Accessory Use Name No Status
Reqd Perm Prop
A (RAJ KUMAR MENGOTIA) Rain Water Harvesting 1 - 1 OK
   
   


[-] Floor Details (Table 9)
   

[-] Building:A (RAJ KUMAR MENGOTIA)


[-] Floor:BASEMENT FLOOR PLAN



No Room Found.


[-] Floor:GROUND FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.

[-] Floor:TYPICAL - 1 & 2 FLOOR PLAN



All Dimensions and Area of all the Rooms on this Floor are as per the Rules.


   


[-] Summary (Table 10)
   
Name Perm./Reqd. Proposed Status
  Plot Area - 128.44 OK
  Plot Width - 6.33 OK
  Plot Depth - 20.28 OK
  Access Width - 12.10 OK
  Plot Frontage - 6.33 OK
  Coverage Area 89.91 83.53 OK
  FAR Area
Bldg. FAR Area : 261.23
Sanctioned FAR Area :0.00
321.10 261.23 OK





[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Width No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Plot Depth No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
Access Width The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
Plot Frontage No rule provided for Min. Plot size for proposed Use or Multistoried Building {Updated as per JBBL, Amendment VIII dated 16/03/2021}
FAR Area (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Residential Building on abutting roadwidth 9.10 (30 ft.) to 12.20 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building upto 10.0 mt. Ht. having Plot Depth 15-21 mt. and Plot width 15-21 mt., Margin required in Front shall be 2.5 mt., Rear 1.5 mt. and Atleast 0.9 mt. shall be provided at one side. {As per Rule No. 36 (Table 8 & 9)}
Basement Margin Rule Basements/cellars may be permitted to be constructed leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 9.10-12.20 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 23.10 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet of suitable height may be constructed to hide installation like water tank and for other such purpose {As per Rule No. 42.5 and Updated as per JBBL, Amendment VIII dated 16/03/2021}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 9.1-12.20 mt. only G+6 floors shall be allowed {As per Rule No. 39.1 Table 15}
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) -
(2) No need to check distance from Building Sewage Treatment Plant
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING
(5) No need to check distance from Building ENT.GATE
(6) -
(7) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number Provision of Rain Water Harvesting shall be mandatory for any use {Updated as per JBBL, Amendment VIII dated 16/03/2021} Rain Water Harvesting
Building Level (Rooms)