No Image Found   

Check List Report

Mango Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 19-03-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0002/W08/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillagePardih
Taluka16
Architect Details
Architect NameL K Suman
License No.MNAC/ENG/0008/2016
Architect Address2nd Floor, Basant Talkies Complex, Sankchi, Jamshedpur
Architect EmailIDlksumanoffice@gmail.com
Architect Mobile No9835131161
Plot Details
Plot Use Commercial
Plot SubUse Commercial Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No4234/4277
NorthSurvey No. - OTHER PLOT
SouthSurvey No. - ROAD
EastSurvey No. - OTHER PLOT
WestRoad Width - 19.82
Owner's Details
NameMRS. KHURSHID JAMAL FATMA POA-SYED SARFRAZ AHMAD
AddressPLOT NO.-4234/4277, KHATA NO.-163, ZAKIR NAGAR ROAD NO.-15 E OLD PURULIA ROAD MANGO
Email IDasifmahmood67@gmail.com
Mobile No8051477770
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 619.40
2 Plot area as per Document by Applicant 619.40
3 Physical area measured at site 619.35
4 Area as per Site Visit (Site Visit Report) 619.40
5Area as per Drawing 619.30

Area of Plot Considered : 619.30

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPROPOSED
Plot OccupancyCommercial
Plot SubUse Commercial Bldg
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 619.30
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 619.30
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 555.39
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 63.90
63.90
Balance Plot Area 555.39

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 309.65
Proposed Coverage Area ( 49.87 % ) 308.83
Total Prop. Coverage Area ( 49.87 % ) 308.83
Balance coverage area ( 0.13 % ) 0.82
FAR CHECK
Perm. FAR Area ( 3.00 ) 1857.90
Total Perm. FAR area 1857.90
Commercial FAR 1548.26
Proposed FAR Area 1566.89
Total Proposed FAR Area 1566.89
Consumed FAR (Factor) 2.53
Balance FAR Area 291.01
BUA CHECK
Total Proposed BuiltUp Area 1912.92


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 50 meter and upto 100 meter -
Existing Road Width 19.8 19.80
Proposed Road Width as per Master Plan 19.8 -
Road Widening Width 0 -
Plot size (as per measurement) 619.4 619.30
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK

     Extra Land Area Details
Name Description Unit Reqd Perm Proposed Status
Extra Land Area Details Extra Land Area - - 0.00 OK

     Plot Related Details
Name Description Unit Reqd Perm Proposed Status
PLOT Plot Area Sq.Mt. - - 619.30 OK
Plot Width Mt. - - 14.27 OK
Plot Depth Mt. - - 43.39 OK
Access Width Mt. 6.10 - 19.80 OK
Plot Frontage Mt. - - 14.10 OK
Coverage Area Sq.Mt. - 309.65 308.83 OK
FAR Area Sq.Mt. - 1857.90 1566.89 OK
Consumed FAR Sq.Mt. - 3.00 2.53 OK
Common Plot Checks Common Plot - Total Area Sq.Mt. 30.97 63.90 OK
Common Plot Tree Cover (Plantation) - Minimum Area Sq.Mt. - 63.90 OK
Tree Cover (Plantation) - Coverage Area Sq.Mt. - - OK
Tree Cover (Plantation) - Width Mt. - 2.06 OK
Tree Cover (Plantation) - Angle Degree - 89.61 OK
Tree Cover (Plantation) - Access Mt. - OK
Tree Tree - Nos Of Trees No. 4 9 OK
Car In Area Sq.Mt. - - 125.00 OK
Total Car In Area Sq.Mt. 125.00 - 125.00 OK
TwoWheeler In Area Sq.Mt. - - 68.00 OK
Total TwoWheeler In Area Sq.Mt. 58.00 - 68.00 OK
Other Parking In Area Sq.Mt. - - 201.20 OK
A-1 (KHURSHID JAMAL FATMA) Front Margin... 19.80 M WIDE MAIN ROAD Mt. 7.50 - 8.12 OK
Rear Margin Mt. 4.50 - 4.50 OK
Side1 Margin Mt. 2.00 - 2.01 OK
Side2 Margin Mt. 2.00 - 2.00 OK

     Building Related Details
Name Description Unit Reqd Perm Proposed Status
A (KHURSHID JAMAL FATMA) Height Mt. 37.82 15.00 OK
A (KHURSHID JAMAL FATMA) Fourth Floor - Height Mt. 2.75 - 3.00 OK
Fourth Floor - Clear Height Mt. 2.75 - 2.90 OK
Fourth Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Third Floor - Height Mt. 2.75 - 3.00 OK
Third Floor - Clear Height Mt. 2.75 - 2.90 OK
Third Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Second Floor - Height Mt. 2.75 - 3.00 OK
Second Floor - Clear Height Mt. 2.75 - 2.90 OK
Second Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
First Floor - Height Mt. 2.75 - 3.00 OK
First Floor - Clear Height Mt. 2.75 - 2.90 OK
First Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Ground Floor - Height Mt. 2.75 - 3.00 OK
Ground Floor - Clear Height Mt. 2.75 - 2.90 OK
Ground Floor - Beam Clear Height Mt. 2.40 - 2.70 OK
Lower Ground Floor - Height Mt. 2.75 - 2.85 OK
Lower Ground Floor - Clear Height Mt. 2.75 - 2.75 OK
Lower Ground Floor - Beam Clear Height Mt. 2.40 - 2.55 OK
A (KHURSHID JAMAL FATMA) Terrace Floor - Height Mt. 1.00 1.20 1.10 OK
A (KHURSHID JAMAL FATMA) No. of Floors No. - 6 OK
No. of Tenements No. - 5 OK
A (KHURSHID JAMAL FATMA) Number Of Lift(s) No. 2 2 OK
A (KHURSHID JAMAL FATMA) GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
GROUND FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
GROUND FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
FIRST FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
FIRST FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Width Mt. 1.70 1.70 OK
TYPICAL - 2, 3& 4 FLOOR PLAN - Lift - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
TERRACE FLOOR PLAN - Lift Machine Room - Width Mt. 1.70 1.70 OK
TERRACE FLOOR PLAN - Lift Machine Room - Depth Mt. 1.90 1.90 OK
LOWER GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
GROUND FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.158 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.920 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
FIRST FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.920 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TYPICAL - 2, 3& 4 FLOOR PLAN STAIRCASE - Flight Width Mt. 0.900 1.500 OK
STAIRCASE - Tread Width Mt. 0.250 0.300 OK
STAIRCASE - Riser Height Mt. 0.200 0.125 OK
STAIRCASE - Riser No. On Flight No. - 14 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
STAIRCASE - Flight Width Mt. 0.900 0.920 OK
STAIRCASE - Tread Width Mt. 0.250 0.250 OK
STAIRCASE - Riser Height Mt. 0.200 0.150 OK
STAIRCASE - Riser No. On Flight No. - 10 OK
STAIRCASE - Cabin Ht. Mt. - - - OK
TERRACE FLOOR PLAN STAIRCASE - Flight Width Mt. - 1.500 OK
STAIRCASE - Tread Width Mt. - 0.300 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
STAIRCASE - Flight Width Mt. - 0.920 OK
STAIRCASE - Tread Width Mt. - 0.250 OK
STAIRCASE - Riser Height Mt. - - OK
STAIRCASE - Riser No. On Flight No. - - OK
STAIRCASE - Cabin Ht. Mt. - - 2.400 OK
RAIN WATER HARVESTING Area Sq.Mt. - - 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
ENT.GATE Area Sq.Mt. - - 1.03 OK
Width Mt. - - 0.30 OK
Depth Mt. - - 3.75 OK
Height Mt. - - - OK
Area Sq.Mt. - - 1.20 OK
Width Mt. - - 0.30 OK
Depth Mt. - - 4.00 OK
Height Mt. - - - OK
SOLAR HEATING SYSTEM Area Sq.Mt. - - 4.00 OK
Width Mt. - - 2.00 OK
Depth Mt. - - 2.00 OK
Height Mt. - - - OK
A (KHURSHID JAMAL FATMA) Rain Water Harvesting - No No. 1 - 1 OK
Entrance Gate - No No. 1 - 2 OK
PROPOSED 16.50 mt. long 1.65 mt. High 3.60 mt. Wide Natural Slope - Width Mt. - 4.39 OK
16.50 mt. long 1.65 mt. High 3.60 mt. Wide Natural Slope - Depth Mt. - 1.65 OK
16.50 mt. long 1.65 mt. High 3.60 mt. Wide Natural Slope - Slope Ratio - - - OK
Ramp No. A (KHURSHID JAMAL FATMA) - LOWER GROUND FLOOR PLAN - No. No. 1 1 OK
   
    All Rooms are as per Rule in Room Checking




[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Commercial Building upto 16.4 mt. Ht. having Plot Depth 39-45 mt. and Plot width 10-15 mt., Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 2.0 mt. shall be provided on both side. {As per Rule No. 36 Table 10 & 11}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well shall not be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(2) No need to check distance from Building RAIN WATER HARVESTING
(3) No need to check distance from Building ENT.GATE
(4) -
(5) No need to check distance from Building SOLAR HEATING SYSTEM
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)