Failed List Report

Mango Municipal Corporation

Version Number: 1.0.43  
Version Date: 29/04/2019 
Report Generated On: 20-03-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0040/W09/2018
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentRevision
Revise Case TypeBefore 15th Sept 2004
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Layout Sanction No0060
Layout Sanction Date13/3/2019
Architect Details
Architect NameNALIN GOEL
License No.MNAC/ARC/0001/2018
Architect Address3533 SATMALA VIJAYA HERITAGE PHASE 7, KADMA
Architect EmailIDshivnal@gmail.com
Architect Mobile No9334613681
Plot Details
Plot Use Commercial
Plot SubUse ResiComm Bldg
PlotNearbyReligiousStructure NA
Plot/SubPlot No683
NorthPlot No. - 678
SouthRoad Width - 18.50
EastPlot No. - 682
WestPlot No. - KERALA PUBLIC SCHOOL - 681
Owner's Details
NameAAKASH INDIA PROJECTS AND BUILDERS PVT LTD
AddressPAYAL CINEMA COMPLEX, MANGO, JAMSHEDPUR
Email IDvishalsawa@gmail.com
Mobile No9334800628
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 2417.38
2 Plot area as per Document by Applicant 2417.38
3 Physical area measured at site 2417.38
4 Area as per Site Visit (Site Visit Report) 2417.38
5Area as per Drawing 2444.26

Area of Plot Considered : 2417.38

Plot area provided in drawing shall not be more than Plot area as per Document.
[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyCommercial
Plot SubUse ResiComm Bldg
Building StructureMultistoried
Building TypeSingle Detached House
Gross Plot Area 2417.38
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 2417.38
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 2135.45
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 281.93
281.93
Balance Plot Area 2135.45

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 50.00 % ) 1208.69
Proposed Coverage Area ( 49.94 % ) 1207.26
Total Prop. Coverage Area ( 49.94 % ) 1207.26
Balance coverage area ( 0.06 % ) 1.43
FAR CHECK
Perm. FAR Area ( 3.00 ) 7252.14
Total Perm. FAR area 7252.14
Residential FAR 4394.15
Commercial FAR 2229.92
Proposed FAR Area 6636.66
Total Proposed FAR Area 6636.66
Consumed FAR (Factor) 2.75
Balance FAR Area 615.48
BUA CHECK
Total Proposed BuiltUp Area 8545.00


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Exceeding 100 meter and upto 250 meter -
Existing Road Width 18.5 18.50
Proposed Road Width as per Master Plan 18.5 -
Road Widening Width 0 -
Plot size (as per measurement) 2417.38 2444.26
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Width The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Plot Depth The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage The minimum size of plot for High rise building or Building with a height of 15 meters and above shall be 1000.0 sq.mt.{As per Rule no. 35.1 Note 4}
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 18.30 (60 ft) and above, the Floor Area Ratio-FAR shall be 3.0 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
Common Plot (1) ; In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(2) ;
(3) In case of multi-storied buildings/ Group Housing /Apartment building/ Industrial/ Assembly/ Educational/ Institutional buildings, it is desirable that at least 10% of the land shall be covered by plantation (tree cover) {As per Rule No.33}
(4) ;
Tree Number Mini. 8 Trees shall be required for the Plot area above 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Multistoried Building, having Building Height 19.25-23.10 mt.,Margin required in Front shall be 7.5 mt., Rear 4.5 mt. and 4.5 mt. shall be provided on both side. {As per Rule No. 37 Table 14}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width above 18.30 mt., No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Maximum two basements/cellars may be permitted to be constructed for the plot size above 750 sq.mt. leaving the prescribed set back/open space applicable to the building {As per Rule No. 48}
Floor Number For old area location,on Road width 18.30 mt. and above, No restriction on height and number of floors however it may be regulated by the master plan/development plan/zonal plan {As per Rule No. 39.1 Table 15}
VShaft For Building upto 24.0 mt. Ht.,Size of Ventilation shaft shall be 5.4 sq.mt. with mini 1.8 mt. width {As per clause-8.2.5(b), Part-3 of National Building Code of India}
Balcony For setback more than 2.5 meters projected balcony shall be allowed with a width of 1.2 meters {As per Rule No. 46.4}
Passage No exit doorway shall be less than 1.00 m. in width. {As per Rule No.43.4.2} ;
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Non-Residential Building, Minimum number of lifts to be 2 for all non-residential building above ground + 2 and the minimum capacity shall be 6 persons per floor. {As per Rule No. 49.2.3 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) Width of the Fire Stair case shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. {As per Rule No. 43.5.3.6}
(4) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
(5) No Rule Defined
(6) ; No Rule Defined
(7) No Rule Defined
(8) ; Number of riser shall not exceed 16 per flight of stairs. {As per Rule No. 43.5.3.6}
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. (1) For parking spaces in basements and upper storey of parking floors, if car parking is more then 40 two ramp of minimum of 3.30m width if it is straight and 3.60m width if it is curved and 5.4m width if one ramp is required shall be provided
(2) -
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4) No need to check distance from Building RAIN WATER HARVESTING 3.00 DIA & 3.0 M. DEPTH
(5) Security Cabin of maximum size of 4 sq.m. with minimum width or diameter of 2 mt. shall be taken Free from FAR
(6) No need to check distance from Building Security Cabin
(7) No need to check distance from Building ENT.GATE
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) Provision of toilets for visitors and separate toilets for guards and drivers shall be provided for Multistoried for Commercial and multidwelling units including Apartments Toilet
(3) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)