-
No Image Found   

Failed List Report

Mango Municipal Corporation

Version Number: 1.0.50  
Version Date: 16/10/2020 
Report Generated On: 25-11-2020 
 

[-] Collapse All


General Details
RegionJHARKHAND URBAN LOCAL BODIES
DistrictEAST SINGHBHUM
AuthorityMANGO MUNICIPAL CORPORATION
Inward_NoMNAC/BP/0042/W10/2020
Application TypeGeneral Proposal
Project TypeBuilding Permission
Nature of DevelopmentNew
Location of Development AreaOld Area
City Area/TPScheme NoNA
VillageMango
Taluka16
Architect Details
Architect NameNIKHIL SHUKLA
License No.MNAC/ARC/0002/2018
Architect AddressHOUSE NO- 125, CHANAKYAPURI COLONY, OLD PURULIA ROAD, NEAR JESU MANGO, JAMSHEDPUR
Architect EmailIDnikhil.archi@gmail.com
Architect Mobile No9234459150
Plot Details
Plot Use Mixed
Plot SubUse Mixed
PlotNearbyReligiousStructure NA
Plot/SubPlot No2141 & 2142
NorthPlot No. - PORTION OF PLOT NO- 2141
SouthPlot No. - NIJ
EastPlot No. - PLOT NO- 4362
WestRoad Width - 18.20 MTR WIDE MAIN ROAD
Owner's Details
NameSMT TARABATI GOUR
AddressDIMNA ROAD MANGO, JAMSHEDPUR
Email IDpramodpandit407@gmail.com
Mobile No7463034152
[-] Plot Details (Table 2)

[-] Area From Document (Table 2a)
No. Form Area
1 Deed(Sale Deed, Gift Deed and Lease Deed) or Agreement 499.25
2 Plot area as per Document by Applicant 499.25
3 Physical area measured at site 499.25
4 Area as per Site Visit (Site Visit Report) 499.25
5Area as per Drawing 498.87

Area of Plot Considered : 498.87

[-] Table 2b
Proposal Detail :
UnitMeters
Development Detail :
PlotPLOT
Plot OccupancyMixed
Plot SubUse -
Higher Plot Use
Higher Plot Sub UseMixed
Lower Plot Use
Lower Plot Sub Use
Building StructureNon-Highrise
Building TypeSingle Detached House
Gross Plot Area 498.87
Net Plot Area (Gross Plot Area - Deduction from Gross Plot area) 498.87
Balance Plot Area (Net Plot Area - Recreational/Amenity space) 417.66
Deductions for Balance Plot Area (from Gross Plot Area)
- Common Plot 81.21
81.21
Balance Plot Area 417.66

[-] Table 2c
COVERAGE CHECK
Permissible Coverage area ( 60.00 % ) 299.32
Proposed Coverage Area ( 45.75 % ) 228.24
Total Prop. Coverage Area ( 45.75 % ) 228.24
Balance coverage area ( 14.25 % ) 71.08
FAR CHECK
Perm. FAR Area ( 2.50 ) 1247.18
Total Perm. FAR area 1247.18
Residential FAR 221.34
Commercial FAR 906.07
Proposed FAR Area 1139.34
Total Proposed FAR Area 1139.34
Consumed FAR (Factor) 2.28
Balance FAR Area 107.84
BUA CHECK
Total Proposed BuiltUp Area 1369.44


[-] Site Visit Data Report
Details Values as per Site Visit Values as per Drawing
Lenght of Road Up to 50 meter -
Existing Road Width 18.2 18.20
Proposed Road Width as per Master Plan 18.2 -
Road Widening Width 0 -
Plot size (as per measurement) 499.25 498.87
[-] Extra Land Area Checks
Name Area Status
Reqd Prop
Extra Land - 0.00 OK
   



[-] Rules
Topic Rule
Plot Level
Plot Area No rule provided for Min. Plot size for proposed Use
Plot Width No rule provided for Min. Plot size for proposed Use
Plot Depth No rule provided for Min. Plot size for proposed Use
Access Width The minimum width of abutting road for any Building more than 13.3 mt. ht. shall be 6.1 mt.{As per Rule no. 35.1 Note 4}
Plot Frontage No rule provided for Min. Plot size for proposed Use
FAR Area (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Consumed FAR (1) In Old Area, for Non-Residential Building on abutting roadwidth 12.20 (40 ft.) to 18.30 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2) For MANGO NAC, Max. 3.0 permissible FAR may be permitted for Commercial or Mercantile type Use {As per Annexure III}
Common Plot Area In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
Common Plot (1) In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2) ;
Tree Number 4-8 Trees shall be required for the Plot area above 250.0 and upto 1000.0 sq.mt. (As per Rule No. 20.1.6)
Margin Rule For Non-highrise Residential Building 13.3-16.4 mt. Ht. having Plot Depth 33-39 mt. and Plot width 10-15 mt., Margin required in Front shall be 4.5 mt., Rear 4.0 mt. and 1.0 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9 and updated as per 4th Amendment dated 2nd Jan, 2019}
Basement Margin Rule In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
Building Level
Building Height For old area, on Road width 12.20-18.30 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 30.0 mt. {As per Rule No. 39.1 Table 15}
Floor Height (1) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(2) The height of all rooms for human habitation shall not be less than 2.75 m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab){As per Rule No.42.2.1}
(3) o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
Parapet Height Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
Below GL Floor Height ,
Basement Floor No. Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
Floor Number For old area location,on Road width 12.20-18.30 mt., Maximum Height 30 meter shall be allowed. {As per Rule No. 39.1 Table 15}
Lift Count (1) The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(2) For Residential Building height upto 15.0 mt or upto G+4 floors, No Lift is reqd. {As per Amended 06-06-2019 Rule No. 49.1.1}
Lift (1) The area of lift well shall not be counted for F.A.R calculation)
(2) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(3) The area of lift well at one floor only (not the sum of total area of lift well at every floor) shall be counted for F.A.R calculation)
(4) The lift shall have a minimum width 1.9 mt. and minimum depth 2.5 mt.{As per clause no 4 and page no. 14 NBC }
(5) -
StairCase (1) Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2) ; No Rule Defined
(3) No Rule Defined
(4) ; No Rule Defined
Ramp No Need to Check Natural Slope width, Depth or height. ;
Ramp No. For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
Plot / Building Level
Accessory Use (1) Common toilet of maximum size of 5 sq.mt shall be taken Free from FAR
(2) No need to check distance from Building Toilet
(3) -
(4) No need to check distance from Building Sewage Treatment Plant
(5) The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(6) No need to check distance from Building RAIN WATER HARVESTING
(7) No need to check distance from Building ENT.GATE
(8) Guard room of max. 10 sq.mt. maximum size of 5 sq.mt shall be taken Free from FAR
(9) No need to check distance from Building GUARD ROOM
(10) -
(11) No need to check distance from Building SOLAR HEATING SYSTEM
(12) Electric cabin or substation of maximum size of 4 sq.m. with minimum width or diameter of 2 m
(13) No need to check distance from Building Generator Room
Accessory Use Number (1) Provision of rainwater harvesting shall be mandatory for 300 sqm. and above size of plots-The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area Rain Water Harvesting
(2) In case of buildings with a height of 15.0 meters and above or ground coverage more than 500 sqm., the main entrance to the premise shall not be less than 5 (five) meters i n width in order to allow easy access to fire engine Entrance Gate
Building Level (Rooms)