Topic |
Rule |
Plot Level |
Plot Area |
No rule provided for Min. Plot size for proposed Use
|
Plot Width |
No rule provided for Min. Plot size for proposed Use
|
Plot Depth |
No rule provided for Min. Plot size for proposed Use
|
Access Width |
The minimum width of abutting road for any Building shall be with respect to Length of Road {As per Rule No. 34 Table No.6}
|
Plot Frontage |
No rule provided for Min. Plot size for proposed Use
|
FAR Area |
(1)
In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Consumed FAR |
(1)
In Old Area, for Residential Building on abutting roadwidth 7.5 (25 ft.) to 9.10 mt., the Floor Area Ratio-FAR shall be 2.5 {As per Rule No.39, Table 15}
(2)
For MANGO NAC, Max. 2.5 permissible FAR may be permitted for Residential Use {As per Annexure III}
|
Common Plot Area |
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
|
Common Plot |
(1)
In every building area, at least 5% of the land shall be covered by plantation (tree cover). {As per Rule No.33}
(2)
;
|
Tree Number |
2-4 Trees shall be required for the Plot area upto 250.0 sq.mt. (As per Rule No. 20.1.6)
|
Margin Rule |
For Non-highrise Residential Building 10-13.3 mt. Ht. having Plot Depth 10-15 mt. and Plot width 15-21 mt., Margin required in Front shall be 3.0 mt., Rear 1.5 mt. and 1.5 mt. shall be provided on both side. {As per Rule No. 36 (Table 8 & 9)}
|
Basement Margin Rule |
In case of apartment/ group housing/commercial building and basements may be allowed to be constructed under the entire plot area leaving mini. 3 mt. space from the boundary of the premises {As per Rule No. 48}
|
Building Level |
Building Height |
For old area, on Road width 7.50-9.10 mt., Permissible height shall in no case exceed(1.5 times the width oftheroadonwhichtheplot abuts) + Road widening + the front setback or 19.25 mt. {As per Rule No. 39.1 Table 15}
|
Floor Height |
(1)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(2)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(3)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(4)
The height of all rooms for human habitation shall not be less than 2.6m measured from the surface of the floor to the lowest point of the ceiling (bottom of slab) for Low income Housing {As per IS Rule No.8888-1978}
(5)
o Every basement shall be in every part at least 2.4 m. in height from the floor to the soffit of the roof slab or ceiling and mini. Of 2.1 mr. below the soffit of beams {As per Rule No. 48}
|
Parapet Height |
Parapet walls and handrails provided on the edges of roof terraces, balcony, verandah, etc shall not be less than 1.0 m and not more than 1.2 m in height from the finished floor level {As per Rule No. 42.5}
|
Below GL Floor Height |
,
|
Basement Floor No. |
Individual residential and small commercial buildings, plot size upto minimum 750 Sq. Meter may have one basement {As per Rule No. 48}
|
Floor Number |
For old area location,on Road width 7.5-9.1 mt. only G+5 floors shall be allowed {As per Rule No. 39.1 Table 15}
|
Lift |
(1)
The area of lift well shall not be counted for F.A.R calculation)
(2)
The lift shall have a minimum width 1.7 mt. and minimum depth 1.9 mt.{As per clause no 4 and page no. 14 NBC }
(3)
-
|
StairCase |
(1)
Width of Winding staircase shall be mini. 0.90 mt.,Maximum rise 0.20 mt. & Minimum tread 0.25 mt. & Cabin Height 2.1 mt. {As per Rule No. 83.18}
(2)
; No Rule Defined
(3)
No Rule Defined
(4)
; No Rule Defined
|
Ramp |
For parking spaces in basements and upper storey of parking floors,if car parking is less then 40, one ramp of minimum of 3.30m width if it is strait and 4.5m width if it is curved at any point and with minimum slope gradient of 1:7 for depth up to 1.8m and 1:10 for more than 1.8m depth shall be provided {As per Rule No. 41.8 and as per Notification from Govt. of Jharkhand 3141 dated 15/05/2017} ;
|
Ramp No. |
For parking spaces in basements and upper storey of parking floors, if car parking is less then 40 one ramp of minimum of 3.30m width if it is straight and 4.50m width if it is curved shall be provided
|
Plot / Building Level |
Accessory Use |
(1)
-
(2)
No need to check distance from Building Sewage Treatment Plant
(3)
The dimension of recharging pits/trenches shall be at least 6 cubic meters for every 100 Sq. m. of roof area
(4)
No need to check distance from Building RAIN WATER HARVESTING
(5)
-
(6)
No need to check distance from Building SOLAR HEATING SYSTEM
|
Building Level (Rooms) |